[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879840":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},879840,568,2,"多选题","下列关于排水泵站设计要求的叙述中，哪几项错误？( )",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","水泵应选用同一型号，个数不应少于2台且不宜多于8台",false,{"key":16,"text":17,"correct":14},"B","雨水泵站可不设备用泵",{"key":19,"text":20,"correct":21},"C","污水泵站集水池的设计最高水位应按出水管高程确定",true,{"key":23,"text":24,"correct":21},"D","雨水泵站集水池的容积不应小于最大一台水泵5min的出水量","CD","参见《室外排水设计规范》5.4.1条，水泵的选择应根据设计流量和所需扬程等因素确定，且应符合下列要求：(1)水泵宜选用同一型号，台数不应少于2台，不宜大于8台；(2)雨水泵房可不设备用泵。规范5.3.5条：污水泵站集水池的设计最高水位，应按进水管充满度计算。规范5.3.1条第2款：雨水泵站集水池的容积，不应小于最大一台水泵30s的出水量。",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（给排水）","建筑工程",0]