[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879674":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},879674,568,2,"多选题","下列建筑生活排水系统清扫口与检查口设计的叙述中，哪几项错误？( )",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","偏转角不大于45°的排水横管，可不设清扫口或检查口",true,{"key":16,"text":17,"correct":14},"B","塑料排水立管上宜每隔六层设置排水检查口",{"key":19,"text":20,"correct":14},"C","排水管道上的清扫口，应采用与管道同材质的清扫口",{"key":22,"text":23,"correct":24},"D","排水管起端可采用堵头代替清扫口",false,"ABC","依据《建筑给水排水设计规范》4.5.12条，在生活排水管道上，应按下列规定设置检查口和清扫口：①铸铁排水立管上检查口之间的距离不宜大于10m，塑料排水立管宜每六层设置一个检查口；但在建筑物最低层和设有卫生器具的二层以上建筑物的最高层，应设置检查口，当立管水平拐弯或有乙字管时，在该层立管拐弯处和乙字管的上部应设检查口；塑料排水立管是每六层设置一个检查口，而不是每隔六层。故B错误。②水流偏转角大于45°的排水横管上，应设检查口或清扫口，即便流偏转角不大于45°，每隔一定距离，排水横管上仍需设置检查口。故A错误。③排水管起点设置堵头代替清扫口时，堵头与墙面应有不小于0.4m的距离铸铁排水管道设置的清扫口，其材质应为铜质；硬聚氯乙烯管道上设置的清扫口应与管道相同材质。故C错误。",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（给排水）","建筑工程",0]