[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879654":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},879654,568,2,"多选题","下列关于小区及建筑生活给水系统的说法，哪些是正确的？( )",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","小区室外给水系统用水量应满足小区内部全部用水的要求",true,{"key":16,"text":17,"correct":18},"B","采用二次加压供水时，应设置生活用水调节设施，如生活用水低位贮水池",false,{"key":20,"text":21,"correct":18},"C","市政水压在晚上高峰用水不满足设计水压的要求时，应设置加压设备供水",{"key":23,"text":24,"correct":14},"D","建筑高度不超过100m的高层建筑宜采用垂直分区并联供水系统","AD","计算小区总用水量时，应包括该给水系统所供应的全部用水。注意，前提是“该用水系统”，若小区部分用水采用雨水利用或其他天然水源，则该部分用水不需要小区室外给水系统来满足，故A错误。依据《建筑给水排水设计规范》3.3.2A条，采用二次加压供水时，也可采用无调节设施的调速泵组供水，故B错误。市政水压在晚上高峰用水不满足设计水压的要求时，也可采用设高位水箱或高位水池进行调节的措施以保证其水压要求，而不是必须设加压设备供水，故C错误。依据《建筑给水排水设计规范》3.3.6条，建筑高度不超过100m的建筑生活给水系统，宜采用垂直分区并联供水或分区减压的供水方式；建筑高度超过100m的建筑，宜采用垂直串联供水方式。故D正确。",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（给排水）","建筑工程",0]