[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879581":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},879581,568,2,"多选题","下列关于建筑生活排水管道的布置及管材、附件选用的叙述中，哪几项正确？( )",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","建筑内部排水管管材的选用应根据排水水质确定",false,{"key":16,"text":17,"correct":18},"B","建筑内部的排水立管和排水横管均应考虑设置伸缩节",true,{"key":20,"text":21,"correct":14},"C","建筑内部排水管道附件如检查口、清扫口等材质应与其排水管道同材质",{"key":23,"text":24,"correct":18},"D","当厨房烹调或备餐间的上方设有卫生间时，其卫生间应采用同层排水方式","BD","根据《建筑给水排水设计规范》。A选项参见4.5.1条，排水管材选择应符合下列要求。涉及水温和压力，没有涉及水质；B选项参见4.3.10条，塑料排水管道应根据其管道的伸缩量设置伸缩节，伸缩节宜设置在汇合配件处。排水横管应设置专用伸缩节；C选项参见4.5.13.4条，铸铁排水管道设置的清扫口，其材质应为铜质；硬聚氯乙烯管道上设置的清扫口应与管道相同材质；D选项参见4.3.6条，排水横管不得布置在食堂、饮食业厨房的主副食操作、烹调和备餐的上方。当受条件限制不能避免时，应采取防护措施：采用同层排水。",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（给排水）","建筑工程",0]