[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879553":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},879553,568,2,"多选题","",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","排出管管径可减小至DN100",true,{"key":16,"text":17,"correct":14},"B","排水立管与排出管采用两个45°弯头连接",{"key":19,"text":20,"correct":21},"C","一层横支管排入PL-2可行，但二层横支管不能排入PL-1",false,{"key":23,"text":24,"correct":14},"D","排水横支管与排水立管可采用90°顺水三通或45°斜三通连接","ABD","根据《建筑给水排水设计规范》。A选项参见4.3.12条注，单根排水立管的排出管宜与排水立管相同管径；B选项参见4.3.9.3条，排水立管与排出管端部的连接，宜采用两个45°弯头、弯曲半径不小于4倍管径的90°弯头或90°变径弯头；C选项参见，一层横支管排入PL-2距离0.55不大于0.75，不可以排入PL-2，二层横支管(相当于5层楼横支管到5层楼排水立管底部)距离底部0.55不大于0.75，不可以排入PL-1；D选项参见4.3.9.2条，排水管道的横管与立管连接，宜采用45°斜三通或45°斜四通和顺水三通或顺水四通。另查样本存在；91.5°普通顺水三通和91.5°扫入式顺水三通。",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（给排水）","建筑工程",0]