[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879544":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},879544,568,2,"多选题","关于通气管管径，以下设计计算哪些项正确？( )",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","连接1根DN00mm污水立管和1根DN75mm废水立管的专用通气立管，其最小管径应为DN100mm",false,{"key":16,"text":17,"correct":18},"B","排水横支管管径为DN100mm，其环形通气管的最小管径可取DN50mm",true,{"key":20,"text":21,"correct":14},"C","连接1根DN125mm排水立管的自循环通气立管，其管径取100mm",{"key":23,"text":24,"correct":18},"D","高档酒店卫生间浴盆排水管上设器具通气管，其最小管径可取DN32mm","BD","依据《建筑给水排水设计规范》4.6.13条，通气立管长度小于等于50m且两根及两根以上排水立管同时与一根通气立管相连，应以最大一根排水立管按本规范确定通气立管管径，且其管径不宜小于其余任何一根排水立管管径。查规范可知DN100对应DN75，故A错误。可知B正确。依据《建筑给水排水设计规范》4.6.11条，自循环通气立管管径应与排水立管管径相等。故C错误。浴盆排水管可以为DN50mm.此时器具通气管可以为DN32mm，而《建筑给水排水设计规范》4.4.15条中规定“浴池的泄水管宜采用100mm”。故D正确。",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（给排水）","建筑工程",0]