[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879521":3},{"question":4,"library":27},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":25,"analysis":26},879521,568,2,"多选题","下列关于建筑中水处理工艺设计的叙述中，哪几项错误？( )",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","不论采用哪种中水处理工艺，均应设置原水调节构筑物",false,{"key":16,"text":17,"correct":18},"B","中水处理产生的污泥，当污泥量较大时，可直接排至化粪池处理",true,{"key":20,"text":21,"correct":14},"C","当原水为优质杂排水时，设置调节池后可不再设初次沉淀池",{"key":23,"text":24,"correct":18},"D","建筑物内部的小型中水处理站，宜优先采用液氯消毒","BD","依据《建筑中水设计规范》条文说明6.1.1可知选项A正确。依据《建筑中水设计规范》6.1.8条，中水处理产生的沉淀污泥、活性污泥和化学污泥，当污泥量较小时，可排至化粪池处理；当污泥量较大时，可采用机械脱水装置或其他方法进行妥善处理。故B错误。依据《建筑中水设计规范》6.1.2条可知选项C正确。依据《建筑中水设计规范》6.2.19条，中水消毒应符合下列要求：消毒剂宜采用次氯酸钠、二氧化氯、二氯异氰尿酸钠或其他消毒剂；当处理站规模较大并采取严格的安全措施时，可采用液氯作为消毒剂，但必须使用加氯机。故D错误。",{"id":6,"name":28,"category":29,"favorite":30},"专业知识（给排水）","建筑工程",0]