[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879143":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},879143,568,1,"单选题","下列关于污水处理构筑物设计参数及连接管线的说法中，哪项正确？( )",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","污水处理构筑物的设计流量均应按最高日最大时设计流量设计",false,{"key":16,"text":17,"correct":18},"B","曝气时间较长时，生物反应池的设计流量可酌情减少",true,{"key":20,"text":21,"correct":14},"C","初期沉淀池的校核时间不宜小于60min",{"key":23,"text":24,"correct":14},"D","污水厂的构筑物均应设超越管线","根据《室外排水设计规范》6.2.4条，“污水处理构筑物的设计流量，应按分期建设的情况分别计算。生物反应池的设计流量，应根据生物反应池类型和曝气时间确定。曝气时间较长时，设计流量可酌情减少”，故A项错误，B项正确。根据《室外排水设计规范》6.2.5条，“初次沉淀池，一般按旱流污水量设计，用合流设计流量校核，校核的沉淀时间不宜小于30min”，C项错误。根据《室外排水设计规范》6.1.15条，“污水厂应合理布置处理构筑物的超越管渠”，D项错误。",{"id":6,"name":27,"category":28,"favorite":29},"专业知识（给排水）","建筑工程",0]