[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879125":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},879125,568,1,"单选题","以下关于城镇排水管道系统选择中，哪项正确？( )",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","雨水管道系统之间或合流制管道系统之间，严禁设置联通管",false,{"key":16,"text":17,"correct":18},"B","排水管道系统的设计，应以重力流为主，不设或少设提升泵站",true,{"key":20,"text":21,"correct":14},"C","输送腐蚀性污水的管道须采用耐腐蚀的材料，但接口及附属构筑物可不做防腐处理",{"key":23,"text":24,"correct":14},"D","排水管道断面尺寸应按远期规划的最高日平均时设计流量设计，按现状水量复核","A项错误，见《室外排水设计规范》4.1.11条：雨水管道系统之间或合流管道系统之间可根据需要设置连通管。必要时可在连通管处设闸槽或闸门。连接管及附近闸门井应考虑维护管理的方便。B项见规范4.1.7条：排水管渠系统的设计，应以重力流为主，不设或少设提升泵站。当无法采用重力流或重力流不经济时，可采用压力流。C项见规范4.1.4条：输送腐蚀性污水的管渠必须采用耐腐蚀材料，其接口及附属构筑物必须采取相应的防腐蚀措施。D项见规范4.1.1条：排水管渠系统应根据城镇总体规划和建设情况统一布置，分期建设。排水管渠断面尺寸应按远期规划的最高日最高时设计流量设计，按现状水量复核，并考虑城市远景发展的需要。",{"id":6,"name":27,"category":28,"favorite":29},"专业知识（给排水）","建筑工程",0]