[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879028":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},879028,568,1,"单选题","下列关于建筑生活给水系统配水管网水力计算的说法中，哪项正确？( )",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","采用分水器配水时，局部水头损失最小",true,{"key":16,"text":17,"correct":18},"B","室内配水管道的局部水头损失小于其沿程水头损失",false,{"key":20,"text":21,"correct":18},"C","沿程水头损失与管材有关，局部水头损失与管(配)件形式无关",{"key":23,"text":24,"correct":18},"D","管件内径大于管道内径的局部水头损失小于管件为凹口螺纹的局部水头损失","参见《建筑给水排水设计规范》第3.6.11条，生活给水管道的配水管的局部水头损失，宜按管道的连接方式，采用管(配)件当量长度法计算。当管道的管(配)件当量长度资料不足时，可按下列管件的连接状况，按管网的沿程水头损失的百分数取值：1.管(配)件内径与管道内径一致，采用三通分水时，取25%～30%；采用分水器分水时，取15%～20%；2.管(配)件内径略大于管道内径，采用三通分水时，取50%～60%；采用分水器分水时，取30%～35%；3.管(配)件内径略小于管道内径，管(配)件的插口插入管口内连接，采用三通分水时，取70%～80%；采用分水器分水时，取35%-40%。B项，H=I×L；当管件当量长度大于管长时，局部损失大于沿程损失；C项参见规范P128，注：本表的螺纹接口是指管件无凹口的螺纹，即管件与管道在连接点内径有突变，管件内径大于管道内径。当管件为凹口螺纹，或管件与管道为等径焊接，其折算补偿长度取本表值的1\u002F2，所以D项也错误。",{"id":6,"name":27,"category":28,"favorite":29},"专业知识（给排水）","建筑工程",0]