[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-879009":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},879009,568,1,"单选题","某建筑内二根长50m，直径分别为DN100mm、DN75mm的排水立管共用一根通气立管，则该通气立管的管径应为下列哪一项？( )",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","50mm",false,{"key":16,"text":17,"correct":14},"B","75mm",{"key":19,"text":20,"correct":21},"C","100mm",true,{"key":23,"text":24,"correct":14},"D","125mm","参见《建筑给水排水设计规范》4.6.13条：“通气立管长度小于等于50m时，且两根及两根以上排水立管同时与一根通气立管相连，应以最大一根排水立管按本规范确定通气立管管径，且管径不宜小于其余任何一根排水立管管径”。4.6.12条：“通气立管长度在50m以上时，其管径应与排水立管管径相同。”注意以上50m的长度是针对通气立管的长度而言的，如果排水立管是50m，一般认为此时通气立管是大于50m的。",{"id":6,"name":27,"category":28,"favorite":29},"专业知识（给排水）","建筑工程",0]