[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-878902":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},878902,568,1,"单选题","下列关于建筑给水系统加压设施设计的说法中，哪项正确？( )",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","当两台水泵为一用一备时，其出水管上共用止回阀和阀门",false,{"key":16,"text":17,"correct":14},"B","当水泵从水箱(池)自灌式直接吸水加压时，其吸水管口未设置喇叭口",{"key":19,"text":20,"correct":21},"C","当由高位水箱供水且其内底板面高度满足最高层用水要求时，未设增压设施",true,{"key":23,"text":24,"correct":14},"D","当高位水箱采用水泵加压补水时，采用直接作用式浮球阀控制水箱水位","依据《建筑给水排水设计规范》3.8.9条，每台水泵的出水管上，应装设压力表、止回阀和阀门。一用一备时也应分别装设，故A错误。依据规范3.8.6条，水泵宜自灌吸水，卧式离心泵的泵顶放气孔、立式多级离心泵吸水端第一级(段)泵体可置于最低设计水位标高一下，每台水泵宜设置单独从水池吸水的吸水管。吸水管内的流速宜采用1.0～1.2m\u002Fs；吸水管口应设置喇叭口。故B错误。依据规范3.7.5条，水箱的设置高度(以底板面计)应满足最高层用户的用水水压要求，当达不到要求时，宜采取管道增压措施。故C正确。依据规范3.7.7条，水塔、水池、水箱等构筑物应设进水管、出水管、溢流管、泄水管和信号装置，当水箱采用水泵加压进水时，应设置水箱水位自动控制水泵开、停的装置，浮球阀不能自动控制水泵开停。故D错误。",{"id":6,"name":27,"category":28,"favorite":29},"专业知识（给排水）","建筑工程",0]