[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-566-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":598},{"id":5,"name":6,"category":7,"favorite":8},566,"专业基础知识（暖通空调+动力）","建筑工程",0,14,50,947,[13,34,46,53,65,73,85,97,109,121,133,145,157,169,181,193,205,217,229,241,253,265,277,289,301,313,325,337,349,361,373,385,397,409,417,429,437,448,460,472,483,494,506,517,528,540,551,562,574,586],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},877509,1,"单选题","齿轮轮系传动不可能提供以下哪种作用？( )",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","做较远距离的传动",true,{"key":24,"text":25,"correct":26},"B","过载保护",false,{"key":28,"text":29,"correct":26},"C","实现变速与换向",{"key":31,"text":32,"correct":26},"D","获得大传动比","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},877510,"不宜采用凸轮机构的工作场合是( )。",[38,40,42,44],{"key":20,"text":39,"correct":26},"需实现特殊的运动轨迹",{"key":24,"text":41,"correct":26},"需实现预定的运动规律",{"key":28,"text":43,"correct":22},"传力较大",{"key":31,"text":45,"correct":26},"多轴联动控制",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},877511,"一对渐开线外啮合斜齿圆柱齿轮的正确啮合条件是( )。",[50,51,52],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":26},{"key":28,"text":33,"correct":26},{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":24,"analysis":33},877512,"弹性滑动是由( )引起的，弹性滑动是( )避免的。",[57,59,61,63],{"key":20,"text":58,"correct":26},"拉力差，可以",{"key":24,"text":60,"correct":22},"拉力差，无法",{"key":28,"text":62,"correct":26},"摩擦力，可以",{"key":31,"text":64,"correct":26},"摩擦力，无法",{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":67,"options":68,"answer":20,"analysis":33},877513,"齿轮设计中，在满足弯曲强度的条件下，可选择( )的齿数，对传动有利。",[69,71],{"key":20,"text":70,"correct":22},"较多",{"key":24,"text":72,"correct":26},"较少",{"id":74,"libraryId":5,"type":15,"typeLabel":16,"stem":75,"options":76,"answer":24,"analysis":33},877514,"下列哪一项不可能改善螺栓的受力情况？( )",[77,79,81,83],{"key":20,"text":78,"correct":26},"采用悬置螺母",{"key":24,"text":80,"correct":22},"加厚螺帽",{"key":28,"text":82,"correct":26},"采用钢丝螺套",{"key":31,"text":84,"correct":26},"减少支撑面的不平度",{"id":86,"libraryId":5,"type":15,"typeLabel":16,"stem":87,"options":88,"answer":20,"analysis":33},877515,"普通螺纹连接的强度计算，主要是计算( )。",[89,91,93,95],{"key":20,"text":90,"correct":22},"螺杆螺纹部分的拉伸强度",{"key":24,"text":92,"correct":26},"螺纹根部的弯曲强度",{"key":28,"text":94,"correct":26},"螺纹工作表面的挤压强度",{"key":31,"text":96,"correct":26},"螺纹的剪切强度",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":31,"analysis":33},877516,"下列关于电容式压力传感器的叙述，错误的是( )。",[101,103,105,107],{"key":20,"text":102,"correct":26},"压力的变化改变极板间的相对位置，由此引起相应电容量的变化反映了被测压力的变化",{"key":24,"text":104,"correct":26},"为保证近似线性的工作特性，测量时必须限制动极板的位移量",{"key":28,"text":106,"correct":26},"灵敏度高，动态响应好",{"key":31,"text":108,"correct":22},"电容的变化与压力引起的动极板位移之间是线性关系",{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":111,"options":112,"answer":24,"analysis":33},877517,"在测量过程中，多次测量同一个量时，测量误差的绝对值和符号按某一确定规律变化的误差称为( )。",[113,115,117,119],{"key":20,"text":114,"correct":26},"偶然误差",{"key":24,"text":116,"correct":22},"系统误差",{"key":28,"text":118,"correct":26},"疏忽误差",{"key":31,"text":120,"correct":26},"允许误差",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":24,"analysis":33},877518,"某涡轮流量计和涡街流量计均用常温下的水进行过标定，当用它们来测量液氮的体积流量时( )。",[125,127,129,131],{"key":20,"text":126,"correct":26},"均需进行黏度和密度的修正",{"key":24,"text":128,"correct":22},"涡轮流量计需要进行黏度和密度修正，涡街流量计不需要",{"key":28,"text":130,"correct":26},"涡街流量计需进行黏度和密度修正，涡轮流量计不需要",{"key":31,"text":132,"correct":26},"均不需进行黏度和密度的修正",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":31,"analysis":33},877519,"以下关于热阻式热流计的叙述，错误的是( )。",[137,139,141,143],{"key":20,"text":138,"correct":26},"热流测头尽量薄",{"key":24,"text":140,"correct":26},"热阻尽量小",{"key":28,"text":142,"correct":26},"被测物体热阻应比测头热阻小得多",{"key":31,"text":144,"correct":22},"被测物体热阻应比测头热阻大得多",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":28,"analysis":33},877520,"在仪表的下列特性中不属于静态特性的是( )。",[149,151,153,155],{"key":20,"text":150,"correct":26},"灵敏度",{"key":24,"text":152,"correct":26},"线性度",{"key":28,"text":154,"correct":22},"时间常数",{"key":31,"text":156,"correct":26},"变差",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":28,"analysis":33},877521,"在以下四种常用的流量计中测量精度较高的是( )。",[161,163,165,167],{"key":20,"text":162,"correct":26},"节流式流量计",{"key":24,"text":164,"correct":26},"转子流量计",{"key":28,"text":166,"correct":22},"容积式流量计",{"key":31,"text":168,"correct":26},"耙式流量计",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":28,"analysis":33},877522,"下列关于电阻温度计的叙述中，哪条内容是不恰当的？( )",[173,175,177,179],{"key":20,"text":174,"correct":26},"与电阻温度计相比，热电偶温度计能测更高的温度",{"key":24,"text":176,"correct":26},"与热电偶温度计相比，热电阻温度计在温度检测时的时间延迟大些",{"key":28,"text":178,"correct":22},"因为电阻体的电阻丝是用较粗的线做成的，所以有较强的耐振性能",{"key":31,"text":180,"correct":26},"电阻温度计的工作原理是利用金属或半导体的电阻随温度变化的特性",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":24,"analysis":33},877523,"若要监测2个测点的温度差，需将两支热电偶( )。",[185,187,189,191],{"key":20,"text":186,"correct":26},"正向串联",{"key":24,"text":188,"correct":22},"反向串联",{"key":28,"text":190,"correct":26},"正向并联",{"key":31,"text":192,"correct":26},"反向并联",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":24,"analysis":33},877524,"微差式测量法比偏差式测量法( )，比零位式测量法( )。",[197,199,201,203],{"key":20,"text":198,"correct":26},"速度慢，准确度高",{"key":24,"text":200,"correct":22},"准确度高，速度快",{"key":28,"text":202,"correct":26},"速度快，准确度高",{"key":31,"text":204,"correct":26},"准确度低，速度慢",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":28,"analysis":33},877525,"在以下四种测量气流速度的装置中，动态响应速度最高的是( )。",[209,211,213,215],{"key":20,"text":210,"correct":26},"恒温式热线风速仪",{"key":24,"text":212,"correct":26},"恒流式热线风速仪",{"key":28,"text":214,"correct":22},"皮托管",{"key":31,"text":216,"correct":26},"机械式风速计",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":31,"analysis":33},877526,"下列弹性膜片中，不能用作弹性式压力表弹性元件的是( )。",[221,223,225,227],{"key":20,"text":222,"correct":26},"弹簧管",{"key":24,"text":224,"correct":26},"波纹管",{"key":28,"text":226,"correct":26},"金属膜片",{"key":31,"text":228,"correct":22},"塑料膜片",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":24,"analysis":33},877527,"关于氯化锂电阻式湿度计，下述说法错误的是( )。",[233,235,237,239],{"key":20,"text":234,"correct":26},"最高使用温度为55℃",{"key":24,"text":236,"correct":22},"传感器电阻测量电桥与热电阻测量电桥相同",{"key":28,"text":238,"correct":26},"也包含干球温度传感器",{"key":31,"text":240,"correct":26},"稳定性较差",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":28,"analysis":33},877528,"氯化锂电阻湿度计使用组合传感器，是为了( )。",[245,247,249,251],{"key":20,"text":246,"correct":26},"提高测量精度",{"key":24,"text":248,"correct":26},"提高测量灵敏度",{"key":28,"text":250,"correct":22},"扩大测量范围",{"key":31,"text":252,"correct":26},"提高测量稳定性",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":28,"analysis":33},877529,"力平衡式压力变送器中，电磁反馈机构的作用是( )。",[257,259,261,263],{"key":20,"text":258,"correct":26},"克服环境温度变化对测量的影响",{"key":24,"text":260,"correct":26},"进行零点迁移",{"key":28,"text":262,"correct":22},"使位移敏感元件工作在小位移状态",{"key":31,"text":264,"correct":26},"调整测量的量程",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":20,"analysis":33},877530,"精密度表示在同一条件下对同一被测量进行多次测量时( )。",[269,271,273,275],{"key":20,"text":270,"correct":22},"测量值重复一致的程度，反映随机误差的大小",{"key":24,"text":272,"correct":26},"测量值重复一致的程度，反映系统误差的大小",{"key":28,"text":274,"correct":26},"测量值偏离真值的程度，反映随机误差的大小",{"key":31,"text":276,"correct":26},"测量值偏离真值的程度，反映系统误差的大小",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":31,"analysis":33},877531,"仪表的精度等级是指仪表的( )。",[281,283,285,287],{"key":20,"text":282,"correct":26},"示值绝对误差平均值",{"key":24,"text":284,"correct":26},"示值相对误差平均值",{"key":28,"text":286,"correct":26},"最大误差值",{"key":31,"text":288,"correct":22},"基本误差的最大允许值",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":31,"analysis":33},877532,"在节流式流量计的使用中，管道管流方面无须满足的条件是( )。",[293,295,297,299],{"key":20,"text":294,"correct":26},"流体应是连续流动并充满管道与节流件",{"key":24,"text":296,"correct":26},"流体是牛顿流体、单向流且流经节流件时不发生相变",{"key":28,"text":298,"correct":26},"流动是平稳的或随时间缓慢变化",{"key":31,"text":300,"correct":22},"流体应低于最小雷诺数要求，即为层流状态",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":24,"analysis":33},877533,"为减少接触式电动测温传感器的动态误差，下列所采取的措施中正确的是( )。",[305,307,309,311],{"key":20,"text":306,"correct":26},"增设保护套管",{"key":24,"text":308,"correct":22},"减小传感器体积，减少热容量",{"key":28,"text":310,"correct":26},"减小传感器与被测介质的接触面积",{"key":31,"text":312,"correct":26},"选用比热大的保护套管",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":24,"analysis":33},877534,"现有一台测温仪表，其测温范围为50～100℃，在正常情况下进行校验，获得了一组校验结果，其中最大校验绝对误差为±0.6℃，最小绝对误差为士0.2℃，则( )。",[317,319,321,323],{"key":20,"text":318,"correct":26},"该仪表的基本误差为1.2%，精度等级为0.5级",{"key":24,"text":320,"correct":22},"该仪表的基本误差为1.2%，精度等级为1.5级",{"key":28,"text":322,"correct":26},"该仪表的基本误差为0.4%，精度等级为0.5级",{"key":31,"text":324,"correct":26},"该仪表的基本误差为1.6%，精度等级为1.5级",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":28,"analysis":33},877535,"温标是以数值表示的温度标尺，在温标中不依赖于物体物理性质的温标是( )。",[329,331,333,335],{"key":20,"text":330,"correct":26},"华氏温标",{"key":24,"text":332,"correct":26},"摄氏温标",{"key":28,"text":334,"correct":22},"热力学温标",{"key":31,"text":336,"correct":26},"IPTS-68国际实用温标",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":31,"analysis":33},877536,"5-1在恒温式热线风速仪中，对探头上的敏感热线有( )。",[341,343,345,347],{"key":20,"text":342,"correct":26},"敏感元件的内阻和流过敏感元件的电流均不变",{"key":24,"text":344,"correct":26},"敏感元件的内阻变化，流过敏感元件的电流不变",{"key":28,"text":346,"correct":26},"敏感元件的内阻不变，流过敏感元件的电流变化",{"key":31,"text":348,"correct":22},"敏感元件的内阻和流过敏感元件的电流均发生变化",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":31,"analysis":33},877537,"不属于光电式露点湿度计测量范围的气体是( )。",[353,355,357,359],{"key":20,"text":354,"correct":26},"高压气体",{"key":24,"text":356,"correct":26},"低温气体",{"key":28,"text":358,"correct":26},"低湿气体",{"key":31,"text":360,"correct":22},"含油烟、油脂的气体",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":24,"analysis":33},877538,"不能在线连续地检测某种气流湿度变化的湿度测量仪表是( )。",[365,367,369,371],{"key":20,"text":366,"correct":26},"干湿球湿度计",{"key":24,"text":368,"correct":22},"光电露点湿度计",{"key":28,"text":370,"correct":26},"氯化铝电阻湿度计",{"key":31,"text":372,"correct":26},"电解式湿度计",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":20,"analysis":33},877539,"在压力测量中，压力表零点漂移产生的误差属于( )，压力表量程选择不当所造成的误差属于( )。",[377,379,381,383],{"key":20,"text":378,"correct":22},"系统误差，粗大误差",{"key":24,"text":380,"correct":26},"随机误差，粗大误差",{"key":28,"text":382,"correct":26},"系统误差，随机误差",{"key":31,"text":384,"correct":26},"随机误差，系统误差",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":28,"analysis":33},877540,"某压力表测量范围为1～10MPa，精度等级为0.5级，其标尺按最小分格为仪表允许误差刻度，则可分为( )格。",[389,391,393,395],{"key":20,"text":390,"correct":26},"240",{"key":24,"text":392,"correct":26},"220",{"key":28,"text":394,"correct":22},"200",{"key":31,"text":396,"correct":26},"180",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":20,"analysis":33},877541,"3-6下列关于干湿球温度的叙述，错误的是( )。",[401,403,405,407],{"key":20,"text":402,"correct":22},"干湿球温差越大，相对湿度越大",{"key":24,"text":404,"correct":26},"干湿球温差越大，相对湿度越小",{"key":28,"text":406,"correct":26},"在冰点以上使用时，误差较小，低于冰点使用时，误差增大",{"key":31,"text":408,"correct":26},"电动干湿球温度计可远距离传送信号",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":31,"analysis":33},877542,"下列仪表已知其稳定度和各环境影响系数，其中( )的仪表稳定性最差。",[413,414,415,416],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":26},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":22},{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":20,"analysis":33},877543,"用真空压力表测量容器压力的方法属于( )方法。",[421,423,425,427],{"key":20,"text":422,"correct":22},"偏差式测量",{"key":24,"text":424,"correct":26},"零位式测量",{"key":28,"text":426,"correct":26},"微差式测量",{"key":31,"text":428,"correct":26},"间接测量",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":28,"analysis":33},877544,"下图中哪个取压位置是正确的？( )",[433,434,435,436],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":26},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":26},{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":439,"answer":28,"analysis":33},877545,[440,442,444,446],{"key":20,"text":441,"correct":26},"随机，准确，系统，精密，随机，准确，系统，精密，过失，随机，系统，精确",{"key":24,"text":443,"correct":26},"系统，准确，随机，精密，系统，准确，随机，精密，过失，系统，随机，精确",{"key":28,"text":445,"correct":22},"随机，精密，系统，准确，随机，精密，系统，准确，粗大，随机，系统，精确",{"key":31,"text":447,"correct":26},"系统，准确，随机，精确，系统，准确，随机，精确，粗大，系统，随机，精确",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":24,"analysis":33},877546,"热电偶是由 A、B两导体组合成的闭合回路，其中A导体为止檄，当回路的两个接点温度不同时将产生热电势，这个热电势的极性取决于( )。",[452,454,456,458],{"key":20,"text":453,"correct":26},"A导体的温差电势",{"key":24,"text":455,"correct":22},"温度较高的接点处的接触电势",{"key":28,"text":457,"correct":26},"B导体的温差电势",{"key":31,"text":459,"correct":26},"温度较低的接点处的接触电势",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":31,"analysis":33},877547,"某合格测温仪表的精度等级为0.5级，测量中最大示值的绝对误差：为1℃，测量范围的下限为负值，且下限的绝对值为测量范围的10%，则该测温仪表的测量下限值是( )℃。",[464,466,468,470],{"key":20,"text":465,"correct":26},"-5",{"key":24,"text":467,"correct":26},"-10",{"key":28,"text":469,"correct":26},"-15",{"key":31,"text":471,"correct":22},"-20",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":474,"answer":24,"analysis":33},877548,[475,477,479,481],{"key":20,"text":476,"correct":26},"180.28",{"key":24,"text":478,"correct":22},"160.18",{"key":28,"text":480,"correct":26},"168.08",{"key":31,"text":482,"correct":26},"180.20",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":485,"answer":28,"analysis":33},877549,[486,488,490,492],{"key":20,"text":487,"correct":26},"19.3",{"key":24,"text":489,"correct":26},"18.0",{"key":28,"text":491,"correct":22},"17.8",{"key":31,"text":493,"correct":26},"13.4",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":24,"analysis":33},877550,"有一块精度为2.5级、测量范围为0～100kPa的压力表，它的刻度标尺最小应分为( )格。",[498,500,502,504],{"key":20,"text":499,"correct":26},"25",{"key":24,"text":501,"correct":22},"40",{"key":28,"text":503,"correct":26},"50",{"key":31,"text":505,"correct":26},"100",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":508,"answer":20,"analysis":33},877551,[509,511,513,515],{"key":20,"text":510,"correct":22},"47.96",{"key":24,"text":512,"correct":26},"52.04",{"key":28,"text":514,"correct":26},"46.15",{"key":31,"text":516,"correct":26},"54.16",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":519,"answer":28,"analysis":33},877552,[520,522,524,526],{"key":20,"text":521,"correct":26},"3.27",{"key":24,"text":523,"correct":26},"16.69",{"key":28,"text":525,"correct":22},"21.91",{"key":31,"text":527,"correct":26},"81.75",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":31,"analysis":33},877553,"霍尔压力传感器的主要缺点是( )。",[532,534,536,538],{"key":20,"text":533,"correct":26},"灵敏度低",{"key":24,"text":535,"correct":26},"不能配用通用的动圈仪表",{"key":28,"text":537,"correct":26},"必须采用稳压电源供电",{"key":31,"text":539,"correct":22},"受温度影响较大",{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":542,"answer":28,"analysis":33},877554,[543,545,547,549],{"key":20,"text":544,"correct":26},"42.6",{"key":24,"text":546,"correct":26},"46.2",{"key":28,"text":548,"correct":22},"48.0",{"key":31,"text":550,"correct":26},"50.0",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":553,"answer":24,"analysis":33},877555,[554,556,558,560],{"key":20,"text":555,"correct":26},"85.9",{"key":24,"text":557,"correct":22},"515.3",{"key":28,"text":559,"correct":26},"1545.9",{"key":31,"text":561,"correct":26},"3091.8",{"id":563,"libraryId":5,"type":15,"typeLabel":16,"stem":564,"options":565,"answer":28,"analysis":33},877556,"下列原理中不能用于速度测量的是( )。",[566,568,570,572],{"key":20,"text":567,"correct":26},"散热率法",{"key":24,"text":569,"correct":26},"动压法",{"key":28,"text":571,"correct":22},"霍尔效应",{"key":31,"text":573,"correct":26},"激光多普勒效应",{"id":575,"libraryId":5,"type":15,"typeLabel":16,"stem":576,"options":577,"answer":28,"analysis":33},877557,"力平衡式压力、压差变送器的测量误差主要来源于( )。",[578,580,582,584],{"key":20,"text":579,"correct":26},"弹性元件的弹性滞后",{"key":24,"text":581,"correct":26},"弹性元件的温漂",{"key":28,"text":583,"correct":22},"杠杆系统的摩擦",{"key":31,"text":585,"correct":26},"位移检测放大器的灵敏度",{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":20,"analysis":33},877558,"为了保证压力表的连接处严密不漏，安装时应根据被测压力的特点和介质性质加装适当的密封垫片。测量乙炔压力时，不得使用( )垫片。",[590,592,594,596],{"key":20,"text":591,"correct":22},"浸油",{"key":24,"text":593,"correct":26},"有机化合物",{"key":28,"text":595,"correct":26},"铜",{"key":31,"text":597,"correct":26},"不锈钢",[599,602,605,608,611,614],{"id":15,"name":600,"category":7,"favorite":601},"领导干部任职前廉政法规知识测试题",92,{"id":603,"name":604,"category":7,"favorite":15},595,"建筑结构与设备",{"id":606,"name":607,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":609,"name":610,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":612,"name":613,"category":7,"favorite":8},534,"BIM工程师",{"id":615,"name":613,"category":7,"favorite":8},535]