[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-564-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":548},{"id":5,"name":6,"category":7,"favorite":8},564,"专业案例（暖通空调专业）","建筑工程",0,9,50,477,[13,30,41,52,63,71,78,86,98,109,120,131,143,151,162,169,178,190,202,214,223,235,246,253,264,276,288,300,311,323,334,346,357,368,379,386,397,409,416,428,439,447,458,470,482,494,506,517,528,536],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":26,"analysis":21},875863,1,"单选题","一建筑物内首层燃气锅炉房长×宽×高为30m×8m×6m，设计正常排风与事故通风的风量不应小于( )。",[19,23,25,28],{"key":20,"text":21,"correct":22},"A","",false,{"key":24,"text":21,"correct":22},"B",{"key":26,"text":21,"correct":27},"C",true,{"key":29,"text":21,"correct":22},"D",{"id":31,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":32,"answer":24,"analysis":21},875864,[33,35,37,39],{"key":20,"text":34,"correct":22},"不变",{"key":24,"text":36,"correct":27},"增大17%",{"key":26,"text":38,"correct":22},"减小17%",{"key":29,"text":40,"correct":22},"增大8%",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":43,"answer":24,"analysis":21},875865,[44,46,48,50],{"key":20,"text":45,"correct":22},"4.8kW",{"key":24,"text":47,"correct":27},"5.8kW",{"key":26,"text":49,"correct":22},"6.8kW",{"key":29,"text":51,"correct":22},"7.8kW",{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":54,"answer":24,"analysis":21},875866,[55,57,59,61],{"key":20,"text":56,"correct":22},"450～500Pa",{"key":24,"text":58,"correct":27},"750～800Pa",{"key":26,"text":60,"correct":22},"950～1000Pa",{"key":29,"text":62,"correct":22},"1200～1300Pa",{"id":64,"libraryId":5,"type":15,"typeLabel":16,"stem":65,"options":66,"answer":20,"analysis":21},875867,"条件同1题，如果送风量为0.33kg\u002Fs，试问送风含湿量为下列何值？",[67,68,69,70],{"key":20,"text":21,"correct":27},{"key":24,"text":21,"correct":22},{"key":26,"text":21,"correct":22},{"key":29,"text":21,"correct":22},{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":73,"answer":24,"analysis":21},875868,[74,75,76,77],{"key":20,"text":21,"correct":22},{"key":24,"text":21,"correct":27},{"key":26,"text":21,"correct":22},{"key":29,"text":21,"correct":22},{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":20,"analysis":21},875869,"WNS2.1-1.0\u002F95\u002F70-Y型锅炉，排烟温度为200℃，送风温度为20℃，鼓风机和引风机风量分别为( )。",[82,83,84,85],{"key":20,"text":21,"correct":27},{"key":24,"text":21,"correct":22},{"key":26,"text":21,"correct":22},{"key":29,"text":21,"correct":22},{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":24,"analysis":21},875870,"某商住楼，首层和二层是三班制工场，采暖室内计算温度为16℃，三层及以上是住宅，每层6户，每户145㎡，采暖室内计算温度为18℃，每户住宅计算采暖热负荷约为4kW，二、三层间楼板传热系数为2W\u002F(㎡·K)，房间楼板传热的处理方法按有关设计规范下列哪一项是正确的？",[90,92,94,96],{"key":20,"text":91,"correct":22},"计算三层向二层传热量，但三层房间采暖热负荷不增加",{"key":24,"text":93,"correct":27},"计算三层向二层传热量，计入三层采暖热负荷中",{"key":26,"text":95,"correct":22},"不需要计算二、三层之间的楼板的传热量",{"key":29,"text":97,"correct":22},"计算三层向二层传热量，但二层房间的采暖热负荷可不减少",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":100,"answer":29,"analysis":21},875871,[101,103,105,107],{"key":20,"text":102,"correct":22},"700Pa",{"key":24,"text":104,"correct":22},"800Pa",{"key":26,"text":106,"correct":22},"900Pa",{"key":29,"text":108,"correct":27},"1000Pa",{"id":110,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":111,"answer":20,"analysis":21},875872,[112,114,116,118],{"key":20,"text":113,"correct":27},"4200～4300W",{"key":24,"text":115,"correct":22},"4400～4500W",{"key":26,"text":117,"correct":22},"4300～4400W",{"key":29,"text":119,"correct":22},"5100～5200W",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":122,"answer":24,"analysis":21},875873,[123,125,127,129],{"key":20,"text":124,"correct":22},"0.25㎡",{"key":24,"text":126,"correct":27},"0.30㎡",{"key":26,"text":128,"correct":22},"0.35㎡",{"key":29,"text":130,"correct":22},"0.40㎡",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":29,"analysis":21},875874,"6级洁净室建成后进行测试，测试粒径为≥0.5μm，每个采样点每次采样量为( )。",[135,137,139,141],{"key":20,"text":136,"correct":22},"0.6L",{"key":24,"text":138,"correct":22},"1.0L",{"key":26,"text":140,"correct":22},"1.5L",{"key":29,"text":142,"correct":27},"2.0L",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":29,"analysis":21},875875,"某燃煤链条热水供暖锅炉的额定产热量为2.8MW，额定热效率为78%，炉膛出口处烟气温度为280℃，炉膛出口处的烟气量为( )。",[147,148,149,150],{"key":20,"text":21,"correct":22},{"key":24,"text":21,"correct":22},{"key":26,"text":21,"correct":22},{"key":29,"text":21,"correct":27},{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":153,"answer":26,"analysis":21},875876,[154,156,158,160],{"key":20,"text":155,"correct":22},"4.6级",{"key":24,"text":157,"correct":22},"4.8级",{"key":26,"text":159,"correct":27},"5.0级",{"key":29,"text":161,"correct":22},"5.2级",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":164,"answer":20,"analysis":21},875877,[165,166,167,168],{"key":20,"text":21,"correct":27},{"key":24,"text":21,"correct":22},{"key":26,"text":21,"correct":22},{"key":29,"text":21,"correct":22},{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":171,"answer":29,"analysis":21},875878,[172,173,174,176],{"key":20,"text":21,"correct":22},{"key":24,"text":21,"correct":22},{"key":26,"text":175,"correct":22},"180",{"key":29,"text":177,"correct":27},"0.168",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":21},875879,"某R22双级蒸气压缩式机组，若已知机组冷凝温度为40℃，冷凝压力为1.534MPa，按制冷性能系数最大原则，确定机组的中间温度为-1℃，中间压力为0.482MPa，则机组的蒸发温度为( )。",[182,184,186,188],{"key":20,"text":183,"correct":27},"-34～-33℃",{"key":24,"text":185,"correct":22},"-43～-42℃",{"key":26,"text":187,"correct":22},"-32～-31℃",{"key":29,"text":189,"correct":22},"-42～-41℃",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":26,"analysis":21},875880,"某办公楼空调制冷系统拟采用冰蓄冷方式，制冷系统的白天运行10h，当地谷价电时间为23：00～7：00，计算日总冷负荷Q=53000kWh，采用部分负荷蓄冷方式(制冷机制冰时制冷能力变化率Cf=0.7)，则蓄冷装置有效容量为下列何项？( )。",[194,196,198,200],{"key":20,"text":195,"correct":22},"5300～5400kW",{"key":24,"text":197,"correct":22},"7500～7600kW",{"key":26,"text":199,"correct":27},"19000～19100kWh",{"key":29,"text":201,"correct":22},"23700～23800kWh",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":24,"analysis":21},875881,"3个热水供暖并联环路，各自的计算阻力为：①环路100kPa；②环路60kPa；③环路40kPa.静态平衡阀全开状态的阻力为30kPa，哪些环路上可以配置平衡阀？( )",[206,208,210,212],{"key":20,"text":207,"correct":22},"①和②环路",{"key":24,"text":209,"correct":27},"②和③环路",{"key":26,"text":211,"correct":22},"①和③环路",{"key":29,"text":213,"correct":22},"①环路",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":26,"analysis":21},875882,"严寒地区A区的某10层矩形办公楼(正南北朝向，平屋顶)，其外围护结构平面几何尺寸为57.6m×14.4m，每层层高均为3.Im，其中南向外窗面积最大(其外窗面积为604.8㎡)，问该朝向的外窗及外墙的传热系数[W\u002F(㎡.K)]应为多少？",[218,219,220,221],{"key":20,"text":21,"correct":22},{"key":24,"text":21,"correct":22},{"key":26,"text":21,"correct":27},{"key":29,"text":222,"correct":22},"应进行权衡判断",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":24,"analysis":21},875883,"某建筑的空调系统采用全空气系统，冬季房间的空调热负荷为100kW(冬季不加湿)，室内计算温度为20℃，冬季室外空调计算温度为-10℃，空调热源为60\u002F50℃的热水，热水量为10000kg\u002Fh，冬季的大气压力为标准大气压，空气密度为1.2kg\u002Fm3，定压比热1.0lkj\u002F(kg.℃)。试问：该系统的新风量为何值？",[227,229,231,233],{"key":20,"text":228,"correct":22},"1400～1500m3\u002Fh",{"key":24,"text":230,"correct":27},"1520～1620m3\u002Fh",{"key":26,"text":232,"correct":22},"1650～1750m3\u002Fh",{"key":29,"text":234,"correct":22},"1770～1870m3\u002Fh",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":237,"answer":29,"analysis":21},875884,[238,240,242,244],{"key":20,"text":239,"correct":22},"1.00W\u002F(㎡·K)",{"key":24,"text":241,"correct":22},"1.16W\u002F(㎡·K)",{"key":26,"text":243,"correct":22},"1.30W\u002F(㎡·K)",{"key":29,"text":245,"correct":27},"1.43W\u002F(㎡·K)",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":248,"answer":24,"analysis":21},875885,[249,250,251,252],{"key":20,"text":21,"correct":22},{"key":24,"text":21,"correct":27},{"key":26,"text":21,"correct":22},{"key":29,"text":21,"correct":22},{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":255,"answer":26,"analysis":21},875886,[256,258,260,262],{"key":20,"text":257,"correct":22},"63.3℃",{"key":24,"text":259,"correct":22},"61.4℃",{"key":26,"text":261,"correct":27},"60.9℃",{"key":29,"text":263,"correct":22},"59.5℃",{"id":265,"libraryId":5,"type":15,"typeLabel":16,"stem":266,"options":267,"answer":24,"analysis":21},875887,"某车间同时散发苯、醋酸乙酯、松节油溶剂蒸汽和余热，为稀释苯、醋酸乙酯、松节油溶剂蒸汽的散发量，所需的室外新风量分别为500000m3\u002Fh、10000m3\u002Fh、2000m3\u002Fh，满足排除余热的室外新风量为510000m3\u002Fh。则能刚满足排除苯、醋酸乙酯、松节油溶剂蒸汽和余热的最小新风量是下列何项？",[268,270,272,274],{"key":20,"text":269,"correct":22},"510000m3\u002Fh",{"key":24,"text":271,"correct":27},"512000m3\u002Fh",{"key":26,"text":273,"correct":22},"520000m3\u002Fh",{"key":29,"text":275,"correct":22},"522000m3\u002Fh",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":26,"analysis":21},875888,"某居住小区的热源为燃煤锅炉，小区供暖热负荷为10MW，冬季生活热水的最大小时耗热量为4MW，夏季生活热水的最小小时耗热量为2.5MW，室外供热管网的输送效率为0.92，不计锅炉房的自用热。锅炉房的总设计容量以及最小锅炉容量的设计最大值应为下列何项？(生活热水的同时使用率为0.8)( )。",[280,282,284,286],{"key":20,"text":281,"correct":22},"总设计容量为11～13MW，最小锅炉容量的设计最大值为5MW",{"key":24,"text":283,"correct":22},"总设计容量为11～13MW，最小锅炉容量的设计最大值为8MW",{"key":26,"text":285,"correct":27},"总设计容量为13.1～14.5MW，最小锅炉容量的设计最大值为5MW",{"key":29,"text":287,"correct":22},"总设计容量为13.1～14.5MW，最小锅炉容量的设计最大值为8MW",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":26,"analysis":21},875889,"已知：1)某空调房间夏季室内设计温度为26℃，设计相对湿度为55%，房间的热湿比为5000kJ\u002Fkg。2)空调器的表冷器的出风干球温度为14℃，相对湿度为90%，送风过程中温升为2℃。当大气压为101325Pa，房间的温度达到设计值，绘出h-d图中的过程线，该房间实际达到的相对湿度(查h-d图)应为下列哪一项？( )",[292,294,296,298],{"key":20,"text":293,"correct":22},"76%～85%",{"key":24,"text":295,"correct":22},"66%～75%",{"key":26,"text":297,"correct":27},"56%～65%",{"key":29,"text":299,"correct":22},"45%～55%",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":302,"answer":26,"analysis":21},875890,[303,305,307,309],{"key":20,"text":304,"correct":22},"35.5kW",{"key":24,"text":306,"correct":22},"37.6kW",{"key":26,"text":308,"correct":27},"77.8kW",{"key":29,"text":310,"correct":22},"102.7kW",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":26,"analysis":21},875891,"按节能标准设计的集中热水采暖系统，设计供回水温差为25℃，室外供回水主干线总长度为1000m，循环水泵采用联轴器连接，水泵设计工况点的轴功率为12kW。该系统的建筑供热负荷约为下列哪一项？",[315,317,319,321],{"key":20,"text":316,"correct":22},"2900kW",{"key":24,"text":318,"correct":22},"3000kW",{"key":26,"text":320,"correct":27},"3100kW",{"key":29,"text":322,"correct":22},"3200kW",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":325,"answer":29,"analysis":21},875892,[326,328,330,332],{"key":20,"text":327,"correct":22},"70%",{"key":24,"text":329,"correct":22},"80%",{"key":26,"text":331,"correct":22},"82%",{"key":29,"text":333,"correct":27},"86%",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":24,"analysis":21},875893,"空调机房内设置有四套组合式空调机组，各系统对应风机的声功率级分别为：K-1，85d B，K-2，80d B，K-3，75d B，K-4，70dB。该空调机房内的最大声功率级应是下列哪一项？( )",[338,340,342,344],{"key":20,"text":339,"correct":22},"85～85.9dB",{"key":24,"text":341,"correct":27},"86～86.9dB",{"key":26,"text":343,"correct":22},"87～87.9dB",{"key":29,"text":345,"correct":22},"88～88.9dB",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":348,"answer":26,"analysis":21},875894,[349,351,353,355],{"key":20,"text":350,"correct":22},"0.7～0.8",{"key":24,"text":352,"correct":22},"0.8～0.9",{"key":26,"text":354,"correct":27},"0.9～1.0",{"key":29,"text":356,"correct":22},"1.0～1.1",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":359,"answer":20,"analysis":21},875895,[360,362,364,366],{"key":20,"text":361,"correct":27},"0.60",{"key":24,"text":363,"correct":22},"4.77",{"key":26,"text":365,"correct":22},"7.94",{"key":29,"text":367,"correct":22},"0.83",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":370,"answer":24,"analysis":21},875896,[371,373,375,377],{"key":20,"text":372,"correct":22},"0.90",{"key":24,"text":374,"correct":27},"0.89",{"key":26,"text":376,"correct":22},"0.88",{"key":29,"text":378,"correct":22},"0.87",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":381,"answer":24,"analysis":21},875897,[382,383,384,385],{"key":20,"text":21,"correct":22},{"key":24,"text":21,"correct":27},{"key":26,"text":21,"correct":22},{"key":29,"text":21,"correct":22},{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":388,"answer":29,"analysis":21},875898,[389,391,393,395],{"key":20,"text":390,"correct":22},"0.18㎡",{"key":24,"text":392,"correct":22},"O.20㎡",{"key":26,"text":394,"correct":22},"0.23㎡",{"key":29,"text":396,"correct":27},"O.25㎡",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":20,"analysis":21},875899,"某机房同时运行3台风机，风机的声功率级分别为83d B.85dB和80d B，试问机房内总声功率级约为下列何值？",[401,403,405,407],{"key":20,"text":402,"correct":27},"88dB",{"key":24,"text":404,"correct":22},"248dB",{"key":26,"text":406,"correct":22},"89dB",{"key":29,"text":408,"correct":22},"85dB",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":411,"answer":24,"analysis":21},875900,[412,413,414,415],{"key":20,"text":21,"correct":22},{"key":24,"text":21,"correct":27},{"key":26,"text":21,"correct":22},{"key":29,"text":21,"correct":22},{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":29,"analysis":21},875901,"-空调建筑空调水系统的供冷量为1000kW，冷水供回水温差为5℃，水的比热为4.18kj\u002F(kg.K)，设计工程的水泵扬程为27m，对应的效率为70%。在设计工况下，水泵的轴功率为下列何值？",[420,422,424,426],{"key":20,"text":421,"correct":22},"10～13kW",{"key":24,"text":423,"correct":22},"13.1～15kW",{"key":26,"text":425,"correct":22},"15.l～17kW",{"key":29,"text":427,"correct":27},"17.1～19kW",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":430,"answer":20,"analysis":21},875902,[431,433,435,437],{"key":20,"text":432,"correct":27},"14～19kJ\u002Fkg",{"key":24,"text":434,"correct":22},"20～25kJ\u002Fkg",{"key":26,"text":436,"correct":22},"26～30kJ\u002Fkg",{"key":29,"text":438,"correct":22},"31～35kJ\u002Fkg",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":29,"analysis":21},875903,"高层建筑内的2层为商场，周边均为固定窗和墙体，该层的防烟分区划为6个，6个防烟分区的面积分别为250，320，450，280，490，390㎡。设计为1个排烟系统，采用1台排烟风机，当按照《高规》和《新措施》的规定进行排烟风机风量选择时，其排烟量的数值应是下列哪一项？( )",[443,444,445,446],{"key":20,"text":21,"correct":22},{"key":24,"text":21,"correct":22},{"key":26,"text":21,"correct":22},{"key":29,"text":21,"correct":27},{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":26,"analysis":21},875904,"某图书馆报告厅，夏季用冷水机组制冷，供回水温差为5℃，水泵扬程为36m，水泵符合节能设计标准的最低效率为( )。",[451,453,455,456],{"key":20,"text":452,"correct":22},"60%",{"key":24,"text":454,"correct":22},"65%",{"key":26,"text":327,"correct":27},{"key":29,"text":457,"correct":22},"72%",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":26,"analysis":21},875905,"某汽一水换热器的换热量为3000kW，一次热媒为表压为0.4MPa的饱和蒸汽(151.85℃)，二次热媒为95℃\u002F70℃热水，设换热器的传热系数为2000W\u002F(㎡·K)，水垢系数取0.9，所需要的换热面积为( )。",[462,464,466,468],{"key":20,"text":463,"correct":22},"22～23㎡",{"key":24,"text":465,"correct":22},"23～24㎡",{"key":26,"text":467,"correct":27},"24～25㎡",{"key":29,"text":469,"correct":22},"25～26㎡",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":20,"analysis":21},875906,"某建筑物空调采用部分负荷冰蓄冷方式，蓄冷装置的有效容量为24255kW·h。制冷机选用螺杆式制冷机。制冷机制冰时制冷能力的变化率，活塞式制冷机可取为0.6，螺杆式制冷机可取为0.7，三级离心式制冷机可取为0.80当地电价谷段计价时间为23：00-7：000如果制冷机白天在空调工况下运行的时间是9：00-21：00，则该蓄冷装置提供的冷负荷占设备计算日总冷负荷的百分比是( )。",[474,476,478,480],{"key":20,"text":475,"correct":27},"30%～35%",{"key":24,"text":477,"correct":22},"40%～45%",{"key":26,"text":479,"correct":22},"25%～30%",{"key":29,"text":481,"correct":22},"50%～55%",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":29,"analysis":21},875907,"某洁净室，室外风速v=4.Sm\u002Fs，密度为ρ=1.293kg\u002Fm3，求满足室内洁净要求的最小压差，",[486,488,490,492],{"key":20,"text":487,"correct":22},"5Pa",{"key":24,"text":489,"correct":22},"10Pa",{"key":26,"text":491,"correct":22},"15Pa",{"key":29,"text":493,"correct":27},"25Pa",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":26,"analysis":21},875908,"某空调区域空气计算参数：室温为28℃，相对湿度为55%。室内仅有显热冷负荷8kW。工艺要求采用直流式、送风温差为8℃的空调系统。该系统的设计冷量应为下列何值？(标准大气压，室外计算温度34℃，相对湿度75%)",[498,500,502,504],{"key":20,"text":499,"correct":22},"35～39kW",{"key":24,"text":501,"correct":22},"40～44kW",{"key":26,"text":503,"correct":27},"45～49kW",{"key":29,"text":505,"correct":22},"50～54kW",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":508,"answer":24,"analysis":21},875909,[509,511,513,515],{"key":20,"text":510,"correct":22},"1.10～1.30kg\u002Fs，11～14kW",{"key":24,"text":512,"correct":27},"1.10～1.30kg\u002Fs，14.5～18kW",{"key":26,"text":514,"correct":22},"0.7～0.9kg\u002Fs，7～9kW",{"key":29,"text":516,"correct":22},"0.7～0.9kg\u002Fs，9.1～11kW",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":519,"answer":26,"analysis":21},875910,[520,522,524,526],{"key":20,"text":521,"correct":22},"1层",{"key":24,"text":523,"correct":22},"2层",{"key":26,"text":525,"correct":27},"3层",{"key":29,"text":527,"correct":22},"各层相同",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":21,"options":530,"answer":20,"analysis":21},875911,[531,532,534,535],{"key":20,"text":21,"correct":27},{"key":24,"text":533,"correct":22},"排尘量为3kg\u002Fh",{"key":26,"text":21,"correct":22},{"key":29,"text":21,"correct":22},{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":29,"analysis":21},875912,"第一个过滤器过滤效率为99.8%，第二个过滤器过滤效率为99.9%，问两个过滤器串联的总效率最接近下列哪一项？( )",[540,542,544,546],{"key":20,"text":541,"correct":22},"99.98%",{"key":24,"text":543,"correct":22},"99.99%",{"key":26,"text":545,"correct":22},"99.998%",{"key":29,"text":547,"correct":27},"99.9998%",[549,552,555,558,561,564],{"id":15,"name":550,"category":7,"favorite":551},"领导干部任职前廉政法规知识测试题",92,{"id":553,"name":554,"category":7,"favorite":15},595,"建筑结构与设备",{"id":556,"name":557,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":559,"name":560,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":562,"name":563,"category":7,"favorite":8},534,"BIM工程师",{"id":565,"name":563,"category":7,"favorite":8},535]