[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-564-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":552},{"id":5,"name":6,"category":7,"favorite":8},564,"专业案例（暖通空调专业）","建筑工程",0,6,50,477,[13,33,41,53,64,75,83,95,106,113,120,132,144,156,163,174,185,193,205,217,229,240,251,263,274,285,296,308,320,331,343,355,366,378,389,397,409,421,428,439,451,463,475,486,497,504,512,523,534,541],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":17},875713,1,"单选题","",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","水泵运行功率超过额定功率10%，水泵可以正常运行",false,{"key":24,"text":25,"correct":22},"B","水泵运行功率超过额定功率15%，水泵可以正常运行",{"key":27,"text":28,"correct":22},"C","水泵运行功率超过额定功率20%，水泵不能正常运行",{"key":30,"text":31,"correct":32},"D","水泵运行功率超过额定功率25%，水泵不能正常运行",true,{"id":34,"libraryId":5,"type":15,"typeLabel":16,"stem":35,"options":36,"answer":24,"analysis":17},875714,"设计严寒地区A区某正南北朝向的九层办公楼，外轮廓尺寸为54m×15m，南外窗为16个通高竖向条形窗(每个窗宽2.1m)，整个顶层为多功能厅，顶部开设一天窗(24m×6m)。一层和顶层层高均为5.4m，中间层层高均为3.9m。问该建筑的南外窗及南外墙的传热系数[W\u002F(㎡.K)]应当是下列哪项？",[37,38,39,40],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":32},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":22},{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":27,"analysis":17},875715,"某燃煤锅炉房有下列负荷(已经考虑了同时使用系数和计入管网的输送热损失)：1)散热器供暖系统(95℃\u002F70℃热水)4MW；2)地板辐射供暖系统(50℃\u002F40℃热水)4MW；3)空调系统(60℃\u002F50℃热水)8MW；4)集中生活热水系统加热(0.5MPa蒸汽)5MW；5)空调加湿(0.2MPa蒸汽)2000kg\u002Fh；6)游泳池水加热等(0.2MPa蒸汽)3500kg\u002Fh。如果统一采用蒸汽锅炉，该锅炉房的蒸汽锅炉总蒸发量应该不小于( )。",[45,47,49,51],{"key":20,"text":46,"correct":22},"30t\u002Fh",{"key":24,"text":48,"correct":22},"32t\u002Fh",{"key":27,"text":50,"correct":32},"36t\u002Fh",{"key":30,"text":52,"correct":22},"40t\u002Fh",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":55,"answer":20,"analysis":17},875716,[56,58,60,62],{"key":20,"text":57,"correct":32},"38m",{"key":24,"text":59,"correct":22},"35m",{"key":27,"text":61,"correct":22},"33m",{"key":30,"text":63,"correct":22},"30m",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":66,"answer":24,"analysis":17},875717,[67,69,71,73],{"key":20,"text":68,"correct":22},"5",{"key":24,"text":70,"correct":32},"6.4",{"key":27,"text":72,"correct":22},"6",{"key":30,"text":74,"correct":22},"7",{"id":76,"libraryId":5,"type":15,"typeLabel":16,"stem":77,"options":78,"answer":24,"analysis":17},875718,"面积为3600㎡、净高为4.3m的商业建筑地下车库，分为两个等面积防烟分区，每个防烟分区的最小排烟量应为( )。",[79,80,81,82],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":32},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":22},{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":24,"analysis":17},875719,"某地冬季室外通风计算温度0℃，供暖室外计算温度-5℃，当地一散发有害气体的车间，冬季工作区供暖计算温度15℃，围护结构耗热量181.8kW。车间屋顶(高12m)设有屋顶风机进行全面通风，排风量8.8kg\u002Fs。当采用全新风集中热风供暖系统，送风量为8kg\u002Fs，车间屋顶梯度为0.5℃\u002Fm时，热风系统的送风温度为下列哪一项？( )",[87,89,91,93],{"key":20,"text":88,"correct":22},"44.1～44.6℃",{"key":24,"text":90,"correct":32},"44.8～45.2℃",{"key":27,"text":92,"correct":22},"45.8～46.2℃",{"key":30,"text":94,"correct":22},"46.8～47.2℃",{"id":96,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":97,"answer":24,"analysis":17},875720,[98,100,102,104],{"key":20,"text":99,"correct":22},"4.5t\u002Fh",{"key":24,"text":101,"correct":32},"5.6t\u002Fh",{"key":27,"text":103,"correct":22},"6.5t\u002Fh",{"key":30,"text":105,"correct":22},"7.5t\u002Fh",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":108,"answer":24,"analysis":17},875721,[109,110,111,112],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":32},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":22},{"id":114,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":115,"answer":24,"analysis":17},875722,[116,117,118,119],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":32},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":22},{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":27,"analysis":17},875723,"沈阳车站大厅补风，风机总效率为60%，按照普通机械通风要求，风机最大压力值不超过( )Pa。",[124,126,128,130],{"key":20,"text":125,"correct":22},"600",{"key":24,"text":127,"correct":22},"634",{"key":27,"text":129,"correct":32},"692",{"key":30,"text":131,"correct":22},"750",{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":30,"analysis":17},875724,"某风冷热泵冷热水机组，仅白天运行，每小时融霜两次。从其样本查得：制冷量修正系数为0.979，制热量修正系数为0.93，额定制热量为331.3kW，试问机组制热量约为下列何值？",[136,138,140,142],{"key":20,"text":137,"correct":22},"292kW",{"key":24,"text":139,"correct":22},"277kW",{"key":27,"text":141,"correct":22},"260kW",{"key":30,"text":143,"correct":32},"247kW",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":30,"analysis":17},875725,"含有剧毒物质或难闻气味物质的局部排风系统，或含有浓度较高的爆炸危险性物质的局部排风系统，排风系统排出口部设计的正确做法，应是下列哪一项？(已知：建筑物正面为迎风面，迎风面长60m、高10m)( )",[148,150,152,154],{"key":20,"text":149,"correct":22},"排至建筑物迎风面",{"key":24,"text":151,"correct":22},"排至建筑物背风面3m高处",{"key":27,"text":153,"correct":22},"排至建筑物两侧面3m高处",{"key":30,"text":155,"correct":32},"排至建筑物背风面8m高处",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":158,"answer":20,"analysis":17},875726,[159,160,161,162],{"key":20,"text":17,"correct":32},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":22},{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":165,"answer":30,"analysis":17},875727,[166,168,170,172],{"key":20,"text":167,"correct":22},"170～185kW",{"key":24,"text":169,"correct":22},"195～210kW",{"key":27,"text":171,"correct":22},"215～230kW",{"key":30,"text":173,"correct":32},"235～250kW",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":176,"answer":24,"analysis":17},875728,[177,179,181,183],{"key":20,"text":178,"correct":22},"3.20～3.70",{"key":24,"text":180,"correct":32},"3.71～4.20",{"key":27,"text":182,"correct":22},"4.21～4.70",{"key":30,"text":184,"correct":22},"4.71～5.20",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":24,"analysis":17},875729,"一建筑物内首层燃油锅炉房长×宽×高为25m×6m×6m，设计正常排风与事故通风时的风量不应小于( )。",[189,190,191,192],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":32},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":22},{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":27,"analysis":17},875730,"北京地区某冷库底层的冷却间，设计温度为-2℃，一面邻外墙，外墙的热惰性指标为3.50已知：北京地区的夏季空调室外计算温度为33.2℃，夏季空调室外日平均计算温度为28.6℃；夏季空调最热月14：00的平均相对湿度为64%(对应露点温度为21.1℃)，夏季空调最热月的平均相对湿度为78%(对应露点温度为24.4℃)，试问该外墙的最小总热阻是下列哪一项？( )",[197,199,201,203],{"key":20,"text":198,"correct":22},"0.20～0.23㎡·℃\u002FW",{"key":24,"text":200,"correct":22},"0.30～0.33㎡·℃\u002FW",{"key":27,"text":202,"correct":32},"0.36～0.39㎡·℃\u002FW",{"key":30,"text":204,"correct":22},"0.40～0.43㎡·℃\u002FW",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":27,"analysis":17},875731,"某热水采暖系统运行时实测流量为9000kg\u002Fh，系统总压力损失为10kPa，现将流量减小为8000kg\u002Fh，系统总压力损失为多少？",[209,211,213,215],{"key":20,"text":210,"correct":22},"0.78～0.80kPa",{"key":24,"text":212,"correct":22},"5.5～5.8kPa",{"key":27,"text":214,"correct":32},"7.8～8.okPa",{"key":30,"text":216,"correct":22},"8.1～8.3kPa",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":27,"analysis":17},875732,"某建筑采用低温地板辐射采暖，按60\u002F50℃热水设计，计算阻力损失为70kPa(其中最不利环路阻力损失为30kPa)，由于热源条件改变，热水温度需要调整为50\u002F43℃，系统和辐射地板加热管的管径不变，但需要增加辐射地板的布管密度，使最不利环路阻力损失增加40kPa，热力人口的供回水压差为下列何值？",[221,223,225,227],{"key":20,"text":222,"correct":22},"应增加为90～110kPa",{"key":24,"text":224,"correct":22},"应增加为120～140kPa",{"key":27,"text":226,"correct":32},"应增加为150～170kPa",{"key":30,"text":228,"correct":22},"应增加为180～200kPa",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":231,"answer":30,"analysis":17},875733,[232,234,236,238],{"key":20,"text":233,"correct":22},"4.3级",{"key":24,"text":235,"correct":22},"4.5级",{"key":27,"text":237,"correct":22},"4.7级",{"key":30,"text":239,"correct":32},"4.9级",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":242,"answer":24,"analysis":17},875734,[243,245,247,249],{"key":20,"text":244,"correct":22},"13m",{"key":24,"text":246,"correct":32},"16m",{"key":27,"text":248,"correct":22},"20m",{"key":30,"text":250,"correct":22},"25m",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":30,"analysis":17},875735,"某储藏苹果的冷却物冷藏间，其计算吨位为530t，进货质量按最大设计。货物进入冷间时的温度为25℃，比焓为336.5kJ\u002Fkg；货物在冷间内终止降温时的温度为0℃，比焓为271.9kJ\u002Fkg。货物冷加工时间按24h计。货物包装材料质量系数取0.25，包装材料的比热容为1.47kJ\u002F(kg·℃)。苹果冷却初始时的呼吸热流量为0.149W\u002Fkg，终止降温时的呼吸热流量为0.019W\u002Fkg。则该冷却物冷藏间的货物热流量为( )。",[255,257,259,261],{"key":20,"text":256,"correct":22},"33.5～35.5kW",{"key":24,"text":258,"correct":22},"35.6～37.5kW",{"key":27,"text":260,"correct":22},"38.5～40.5kW",{"key":30,"text":262,"correct":32},"48.5～50.5kW",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":265,"answer":30,"analysis":17},875736,[266,268,270,272],{"key":20,"text":267,"correct":22},"82.5%～85%",{"key":24,"text":269,"correct":22},"86.5%～90%",{"key":27,"text":271,"correct":22},"91.5%～95.5%",{"key":30,"text":273,"correct":32},"96.5%～99.5%",{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":276,"answer":20,"analysis":17},875737,[277,279,281,283],{"key":20,"text":278,"correct":32},"A点处设防火阀，B点处设防火阀",{"key":24,"text":280,"correct":22},"A点处设防火阀，B点处不设防火阀",{"key":27,"text":282,"correct":22},"A点处不设防火阀，B点处设防火阀",{"key":30,"text":284,"correct":22},"A点处不设防火阀，B点处不设防火阀",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":287,"answer":24,"analysis":17},875738,[288,290,292,294],{"key":20,"text":289,"correct":22},"干球温度为10.5℃、相对湿度为35%",{"key":24,"text":291,"correct":32},"干球温度为9.5℃、相对湿度为40%",{"key":27,"text":293,"correct":22},"干球温度为8.5℃、相对湿度为45%",{"key":30,"text":295,"correct":22},"干球温度为7.5℃、相对湿度为50%",{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":20,"analysis":17},875739,"某工厂车间耗热量的计算结果如下：外墙的传热耗热量为1000W，外窗的传热耗热量为500W，地面耗热量为400W，外门传热耗热量为800W，冷风渗透耗热量为300W，房间长度8m，宽度6m，高度4m，若车间采用低温热水地板局部辐射供暖方式，供暖区面积为24㎡，则该车间的供暖设计热负荷为( )。",[300,302,304,306],{"key":20,"text":301,"correct":32},"1540～1630W",{"key":24,"text":303,"correct":22},"1780～1880W",{"key":27,"text":305,"correct":22},"1980～2080W",{"key":30,"text":307,"correct":22},"2340～2470W",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":24,"analysis":17},875740,"热湿作业车间冬季的室内温度为23℃，相对湿度为70%，采暖室外计算温度为-8℃，RTI=0.115(㎡·K)／W，当地大气压为标准大气压，现要求外窗的内表面不结露，且选用造价低的窗玻璃，应为( )。",[312,314,316,318],{"key":20,"text":313,"correct":22},"K=1.2W／(㎡·K)",{"key":24,"text":315,"correct":32},"K=1.5W\u002F(㎡·K)",{"key":27,"text":317,"correct":22},"K=1.7W／(㎡·K)",{"key":30,"text":319,"correct":22},"K=2.OW／(㎡·K)",{"id":321,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":322,"answer":20,"analysis":17},875741,[323,325,327,329],{"key":20,"text":324,"correct":32},"5.67",{"key":24,"text":326,"correct":22},"5.23",{"key":27,"text":328,"correct":22},"7.58",{"key":30,"text":330,"correct":22},"3.51",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":24,"analysis":17},875742,"热力网与供暖用户采取有混水降温装置的直接连接，热网设计供回水温度为110℃\u002F70℃，用户设计供回水温度为85℃\u002F60℃，用户供暖设计热负荷为100kW，混水装置的设计流量为( )。",[335,337,339,341],{"key":20,"text":336,"correct":22},"2000～2100kg\u002Fh",{"key":24,"text":338,"correct":32},"2100～2200kg\u002Fh",{"key":27,"text":340,"correct":22},"2200～2300kg\u002Fh",{"key":30,"text":342,"correct":22},"2300～2400kg\u002Fh",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":24,"analysis":17},875743,"某空调房间冷负荷142kW，采用全空气空调，空调系统配有新风从排风中回收显热的装置(热交换率η=0.65，且新风量与排风量相等，均为送风量的15%)。已知：室外空气计算干球温度33℃，比焓90kJ\u002Fkg；室内空气计算干球温度26℃，比焓58.1kJ\u002Fkg，当采用室内空气状态下的机器露点(干球温度19℃，比焓51kJ\u002Fkg)送风时，空调设备的冷量(不计过程的冷量损失)为下列哪一项？( )",[347,349,351,353],{"key":20,"text":348,"correct":22},"170～180kW",{"key":24,"text":350,"correct":32},"215～232kW",{"key":27,"text":352,"correct":22},"233～240kW",{"key":30,"text":354,"correct":22},"241～250kW",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":357,"answer":24,"analysis":17},875744,[358,360,362,364],{"key":20,"text":359,"correct":22},"2.50～2.60Pa",{"key":24,"text":361,"correct":32},"2.70～2.80Pa",{"key":27,"text":363,"correct":22},"2.85～3.10Pa",{"key":30,"text":365,"correct":22},"3.20～3.30Pa",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":24,"analysis":17},875745,"容量700人的会议室，室内空气温度为20℃，室外空气温度为16℃。每人总发热量为110W，其中潜热量为30W，外围护结构损耗热量为7000W，所需通风量为下列哪一项？( )",[370,372,374,376],{"key":20,"text":371,"correct":22},"3～5kg\u002Fs",{"key":24,"text":373,"correct":32},"11.5～12.5kg\u002Fs",{"key":27,"text":375,"correct":22},"17～18kg\u002Fs",{"key":30,"text":377,"correct":22},"50～52kg\u002Fs",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":380,"answer":30,"analysis":17},875746,[381,383,385,387],{"key":20,"text":382,"correct":22},"82%，95%",{"key":24,"text":384,"correct":22},"86%，95%",{"key":27,"text":386,"correct":22},"82%，91%",{"key":30,"text":388,"correct":32},"86%，91%",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":27,"analysis":17},875747,"最高工作压力ρ=1500Pa的(N)5级净化空调系统中矩形送风管的允许漏风量为( )。",[393,394,395,396],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":32},{"key":30,"text":17,"correct":22},{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":24,"analysis":17},875748,"某建筑物的空调系统采用水冷冷水机组作为冷源，冷水机组的冷却水由机械通风逆流式玻璃钢冷却塔循环冷却。冷水机组和冷却水泵位于建筑物地下层，冷却塔置于建筑物屋面。冷却水泵出口中心至冷却塔集水盘水面和冷却塔布水器进口中心的距离分别为32.4m和36.9m。冷却塔布水器喷头的喷雾压力为0.041MPa。经水力计算，冷却水管路阻力为0.039MPa。如果冷水机组的冷凝器水侧阻力为0.068MPa，则冷却水泵的扬程应为( )。",[401,403,405,407],{"key":20,"text":402,"correct":22},"0.560～0.570MPa",{"key":24,"text":404,"correct":32},"0.210～0.220MPa",{"key":27,"text":406,"correct":22},"0.160～0.170MPa",{"key":30,"text":408,"correct":22},"0.190～0.200MPa",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":24,"analysis":17},875749,"拟设计一用于“粗颗粒物料的破碎”的局部排风密闭罩。已知：物料下落时带入罩内的诱导空气量为0.35m3\u002Fs，从孔口或缝隙出吸入的空气量为0.50m3／s，则连接密闭罩“圆形吸风口”的最小直径最接近下列哪一项？",[413,415,417,419],{"key":20,"text":414,"correct":22},"0.5m",{"key":24,"text":416,"correct":32},"0.6m",{"key":27,"text":418,"correct":22},"0.7m",{"key":30,"text":420,"correct":22},"0.8m",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":423,"answer":27,"analysis":17},875750,[424,425,426,427],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":32},{"key":30,"text":17,"correct":22},{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":430,"answer":30,"analysis":17},875751,[431,433,435,437],{"key":20,"text":432,"correct":22},"106～107㎡",{"key":24,"text":434,"correct":22},"70～71㎡",{"key":27,"text":436,"correct":22},"96～97㎡",{"key":30,"text":438,"correct":32},"158～162㎡",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":30,"analysis":17},875752,"某集中热水供热系统为3幢建筑供暖，采用设置于1#楼顶的膨胀水箱定压，1#楼系统顶点工作压力为0.15MPa。其中1#楼为10层、2#楼为8层、3#楼为6层，3幢建筑的首层地面绝对标高相同，层高均为3m。3#楼的室内供暖系统如在±0.000m处进行系统水压试验，试验压力应为( )。",[443,445,447,449],{"key":20,"text":444,"correct":22},"0.42～0.43MPa",{"key":24,"text":446,"correct":22},"0.47～0.48MPa",{"key":27,"text":448,"correct":22},"0.54～0.55MPa",{"key":30,"text":450,"correct":32},"0.59～0.60MPa",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":20,"analysis":17},875753,"北京某小区室外供热管网，DN200的供热管道采用岩棉保温，岩棉的导热系数为0.039W\u002F(m·K)，该地区的热价为30元\u002FGJ，下列哪个保温厚度合理？( )",[455,457,459,461],{"key":20,"text":456,"correct":32},"40mm",{"key":24,"text":458,"correct":22},"32mm",{"key":27,"text":460,"correct":22},"30mm",{"key":30,"text":462,"correct":22},"25mm",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":27,"analysis":17},875754,"拟建700床的高级宾馆，当地天然气低热值为35.8MJ\u002Fm3，试估算该工程天然气最大总用气量为下列何值？",[467,469,471,473],{"key":20,"text":468,"correct":22},"＜80m3\u002Fh",{"key":24,"text":470,"correct":22},"80～100m3\u002Fh",{"key":27,"text":472,"correct":32},"101～120m3\u002Fh",{"key":30,"text":474,"correct":22},"＞120m3\u002Fh",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":477,"answer":20,"analysis":17},875755,[478,480,482,484],{"key":20,"text":479,"correct":32},"40～42℃",{"key":24,"text":481,"correct":22},"43～45℃",{"key":27,"text":483,"correct":22},"46～48℃",{"key":30,"text":485,"correct":22},"49～51℃",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":488,"answer":27,"analysis":17},875756,[489,491,493,495],{"key":20,"text":490,"correct":22},"12～12.9g\u002Fkg",{"key":24,"text":492,"correct":22},"13～13.9g\u002Fkg",{"key":27,"text":494,"correct":32},"14～14.9g\u002Fkg",{"key":30,"text":496,"correct":22},"15～15.9g\u002Fkg",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":499,"answer":30,"analysis":17},875757,[500,501,502,503],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":32},{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":24,"analysis":17},875758,"某仓库容积为1000m3，梅雨季节时，所在地的室外计算干球温度为34℃，相对湿度为80%，现要求库内空气温度为30℃，相对湿度为50%，选用总风量为2000m3\u002Fh的除湿机除湿。已知，建筑和设备的散湿量为0.2kg\u002Fh，库内人员的散湿量为0.8kg\u002Fh，库内自然渗透的换气量为每小时一次，按标准大气压考虑，空气密度取1.2kg\u002Fm3时，除湿机出口空气的含湿量应为下列哪一项？",[508,509,510,511],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":32},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":22},{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":514,"answer":20,"analysis":17},875759,[515,517,519,521],{"key":20,"text":516,"correct":32},"550～590kW",{"key":24,"text":518,"correct":22},"600～640kW",{"key":27,"text":520,"correct":22},"650～690kW",{"key":30,"text":522,"correct":22},"700～750kW",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":525,"answer":24,"analysis":17},875760,[526,528,530,532],{"key":20,"text":527,"correct":22},"320.0～326.0kJ\u002Fkg",{"key":24,"text":529,"correct":32},"326.1～332.0kJ\u002Fkg",{"key":27,"text":531,"correct":22},"332.1～340.0kJ\u002Fkg",{"key":30,"text":533,"correct":22},"340.1～345.0kJ\u002Fkg",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":536,"answer":30,"analysis":17},875761,[537,538,539,540],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":27,"text":17,"correct":22},{"key":30,"text":17,"correct":32},{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":543,"answer":30,"analysis":17},875762,[544,546,548,550],{"key":20,"text":545,"correct":22},"50Pa",{"key":24,"text":547,"correct":22},"867Pa",{"key":27,"text":549,"correct":22},"467Pa",{"key":30,"text":551,"correct":32},"517Pa",[553,556,559,562,565,568],{"id":15,"name":554,"category":7,"favorite":555},"领导干部任职前廉政法规知识测试题",92,{"id":557,"name":558,"category":7,"favorite":15},595,"建筑结构与设备",{"id":560,"name":561,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":563,"name":564,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":566,"name":567,"category":7,"favorite":8},534,"BIM工程师",{"id":569,"name":567,"category":7,"favorite":8},535]