[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-564-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":560},{"id":5,"name":6,"category":7,"favorite":8},564,"专业案例（暖通空调专业）","建筑工程",0,5,50,477,[13,34,45,56,68,80,92,103,115,126,138,150,161,168,179,190,201,208,219,226,237,249,260,267,279,290,301,312,324,336,348,360,367,374,385,397,408,419,430,442,454,464,472,484,496,507,519,526,537,549],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},875663,1,"单选题","某办公楼普通机械送风系统风机与电机采用直联方式，设计工况下的风机及传动效率为92.8%，风管的长度为124m，通风系统单位长度平均风压损失为5Pa／m(包含摩擦阻力和局部阻力)。问：在通风系统设计时，所选择的风机在设计工况下效率的最小值应接近以下哪项效率值，才能满足节能要求？( )。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","52%",false,{"key":24,"text":25,"correct":22},"B","53%",{"key":27,"text":28,"correct":22},"C","56%",{"key":30,"text":31,"correct":32},"D","58%",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":36,"answer":27,"analysis":33},875664,[37,39,41,43],{"key":20,"text":38,"correct":22},"7-8",{"key":24,"text":40,"correct":22},"8-9",{"key":27,"text":42,"correct":32},"11-12",{"key":30,"text":44,"correct":22},"13-14",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":47,"answer":30,"analysis":33},875665,[48,50,52,54],{"key":20,"text":49,"correct":22},"25kW",{"key":24,"text":51,"correct":22},"30kW",{"key":27,"text":53,"correct":22},"35kW",{"key":30,"text":55,"correct":32},"40kW",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":30,"analysis":33},875666,"在一般工业区内(非特定工业区)新建某除尘系统，排气筒的高度为20m，排放的污染物为石英粉尘，排放速度速率均匀，经两小时连续测定，标准工况下，排气量V=80000m3\u002Fh，除尘效率η=99%，粉尘收集量为G=633.6kg。试问，以下依次列出排气筒的排放速率值，排放浓度值以及达标排放的结论，正确者应为下列哪一项？",[60,62,64,66],{"key":20,"text":61,"correct":22},"3.Okg\u002Fh，60mg\u002Fm3，达标排放",{"key":24,"text":63,"correct":22},"3.lkg\u002Fh，80mg\u002Fm3，排放不达标",{"key":27,"text":65,"correct":22},"3.0kg\u002Fh，40mg\u002Fm3，达标排放",{"key":30,"text":67,"correct":32},"3.2kg\u002Fh，40mg\u002Fm3，排放不达标",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":24,"analysis":33},875667,"某低温环境试验室的最低温度为-45℃，其相邻的控制室中有一个观察低温试验情况的观察窗，控制室的设计参数为：干球温度25℃，相对湿度60%，气压按101.3kPa计算，观察窗内、外表面的表面传热系数均按8W\u002F(㎡·K)计算，为了以最低成本保证观察窗的观察效果，其传热系数应为( )。",[72,74,76,78],{"key":20,"text":73,"correct":22},"2.00W\u002F(㎡·K)",{"key":24,"text":75,"correct":32},"0.95W\u002F(㎡·K)",{"key":27,"text":77,"correct":22},"0.50W\u002F(㎡·K)",{"key":30,"text":79,"correct":22},"0.30W\u002F(㎡·K)",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":30,"analysis":33},875668,"某车间设有局部排风系统，局部排风量为0.56kg\u002Fs，冬季室内工作区温度为15℃，冬季通风室外计算温度为-15℃，采暖室外计算温度为-25℃(大气压为标准大气压)，空气定压比热1.01kJ(kg.℃)。围护结构耗热量为8.8kW，室内维持负压，机械进风量为排风量的90%，试求机械通风量和送风温度为下列何项？",[84,86,88,90],{"key":20,"text":85,"correct":22},"0.3～0.53kg\u002Fs，29～32℃",{"key":24,"text":87,"correct":22},"0.54～0.65kg\u002Fs，29～32℃",{"key":27,"text":89,"correct":22},"0.54～0.65kg\u002Fs，33～36.5℃",{"key":30,"text":91,"correct":32},"0.3～0.53kg\u002Fs，36.6～38.5℃",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":94,"answer":20,"analysis":33},875669,[95,97,99,101],{"key":20,"text":96,"correct":32},"3.65～3.75kJ\u002Fkg",{"key":24,"text":98,"correct":22},"3.55～3.64kJ\u002Fkg",{"key":27,"text":100,"correct":22},"3.76～3.85kJ\u002Fkg",{"key":30,"text":102,"correct":22},"3.45～3.54kJ\u002Fkg",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":105,"options":106,"answer":30,"analysis":33},875670,"某厂房利用风帽进行自然排风，总排风量L=13842m3\u002Fh，室外风速v=3.16m\u002Fs，不考虑热压作用，压差修正系数A=l.43，拟选用直径d=800mm的筒形风帽，不接风管，风帽入口的局部阻力系数ξ=0.5。问：设计配置的风帽个数为下列何项？(当地为标准大气压)",[107,109,111,113],{"key":20,"text":108,"correct":22},"4(个)",{"key":24,"text":110,"correct":22},"5(个)",{"key":27,"text":112,"correct":22},"6(个)",{"key":30,"text":114,"correct":32},"7(个)",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":117,"answer":30,"analysis":33},875671,[118,120,122,124],{"key":20,"text":119,"correct":22},"0～4%",{"key":24,"text":121,"correct":22},"0～5%",{"key":27,"text":123,"correct":22},"2%～4%",{"key":30,"text":125,"correct":32},"2%～5%",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":30,"analysis":33},875672,"某民用建筑的全面通风系统，系统计算总风量为10000m3\u002Fh，系统计算总压力损失300Pa，当地大气压力为101.3kPa，假设空气温度为20℃。若选用风系统全压效率为0.65、机械效率为0.98，在选择确定通风机时，风机的配用电机容量至少应为下列何项？(风机风量按计算风量附加5%，风压按计算阻力附加10%)",[130,132,134,136],{"key":20,"text":131,"correct":22},"1.25～1.4kW",{"key":24,"text":133,"correct":22},"1.45～1.50kW",{"key":27,"text":135,"correct":22},"1.6～1.75kW",{"key":30,"text":137,"correct":32},"1.85～2.OkW",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":27,"analysis":33},875673,"某洁净房间空气含尘浓度为0.5μm粒子3600个\u002Fm3，其空气洁净等级按国际标准规定的是下列哪一项？并列出判定过程。",[142,144,146,148],{"key":20,"text":143,"correct":22},"4.6级",{"key":24,"text":145,"correct":22},"4.8级",{"key":27,"text":147,"correct":32},"5.0级",{"key":30,"text":149,"correct":22},"5.2级",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":152,"answer":24,"analysis":33},875674,[153,155,157,159],{"key":20,"text":154,"correct":22},"为原热负荷的67.15%～68.8%",{"key":24,"text":156,"correct":32},"为原热负荷的69.1%～70.8%",{"key":27,"text":158,"correct":22},"为原热负荷的71.1%～72.8%",{"key":30,"text":160,"correct":22},"为原热负荷的73.1%～74.8%",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":163,"answer":20,"analysis":33},875675,[164,165,166,167],{"key":20,"text":33,"correct":32},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":30,"text":33,"correct":22},{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":170,"answer":27,"analysis":33},875676,[171,173,175,177],{"key":20,"text":172,"correct":22},"32.5℃",{"key":24,"text":174,"correct":22},"35.4℃",{"key":27,"text":176,"correct":32},"37.5℃",{"key":30,"text":178,"correct":22},"39.5℃",{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":181,"answer":27,"analysis":33},875677,[182,184,186,188],{"key":20,"text":183,"correct":22},"60kg",{"key":24,"text":185,"correct":22},"70kg",{"key":27,"text":187,"correct":32},"80kg",{"key":30,"text":189,"correct":22},"100kg",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":192,"answer":30,"analysis":33},875678,[193,195,197,199],{"key":20,"text":194,"correct":22},"采用液体过冷后制冷系数不能确定",{"key":24,"text":196,"correct":22},"采用液体过冷后制冷系数下降",{"key":27,"text":198,"correct":22},"采用液体过冷后制冷系数不变",{"key":30,"text":200,"correct":32},"采用液体过冷后制冷系数提高",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":203,"answer":30,"analysis":33},875679,[204,205,206,207],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":30,"text":33,"correct":32},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":210,"answer":27,"analysis":33},875680,[211,213,215,217],{"key":20,"text":212,"correct":22},"25～28℃",{"key":24,"text":214,"correct":22},"29～32℃",{"key":27,"text":216,"correct":32},"33～36℃",{"key":30,"text":218,"correct":22},"37～40℃",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":221,"answer":20,"analysis":33},875681,[222,223,224,225],{"key":20,"text":33,"correct":32},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":30,"text":33,"correct":22},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":228,"answer":27,"analysis":33},875682,[229,231,233,235],{"key":20,"text":230,"correct":22},"10%～20%",{"key":24,"text":232,"correct":22},"25%～30%",{"key":27,"text":234,"correct":32},"35%～40%",{"key":30,"text":236,"correct":22},"45%～50%",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":20,"analysis":33},875683,"假设一台冷水机组在100%，75%，50%和25%负荷时的性能系数分别为4.5，4.8，5.1和5.6，对应的冷却水进水温度分别为30，26，23，19℃。其部分负荷综合性能系数为( )。",[241,243,245,247],{"key":20,"text":242,"correct":32},"5.01",{"key":24,"text":244,"correct":22},"4.99",{"key":27,"text":246,"correct":22},"5.13",{"key":30,"text":248,"correct":22},"4.87",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":251,"answer":30,"analysis":33},875684,[252,254,256,258],{"key":20,"text":253,"correct":22},"37.65kW，21.99kW，33.88kW",{"key":24,"text":255,"correct":22},"21.99kW，37.65kW，33.88kW",{"key":27,"text":257,"correct":22},"33.88kW，21.99kW，37.65kW",{"key":30,"text":259,"correct":32},"21.99kW，33.88kW，37.65kW",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":262,"answer":24,"analysis":33},875685,[263,264,265,266],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":32},{"key":27,"text":33,"correct":22},{"key":30,"text":33,"correct":22},{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":30,"analysis":33},875686,"上海某8层住宅楼长×宽×高=30m×10m×25m，外墙采用厚度为225mm的加气混凝土块，屋面传热系数为0.8W\u002F(㎡·K)，外窗窗墙面积比为0.35，外窗传热系数为3.0W\u002F(㎡·K)，关于该住宅楼的建筑热工设计下列哪个说法是正确的？( )",[271,273,275,277],{"key":20,"text":272,"correct":22},"外墙传热系数过大，应加保温",{"key":24,"text":274,"correct":22},"体形系数过大，应改变建筑外形尺寸",{"key":27,"text":276,"correct":22},"应进行热工性能的综合判断",{"key":30,"text":278,"correct":32},"热工设计符合节能标准",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":281,"answer":24,"analysis":33},875687,[282,284,286,288],{"key":20,"text":283,"correct":22},"304kW",{"key":24,"text":285,"correct":32},"297kW",{"key":27,"text":287,"correct":22},"292kW",{"key":30,"text":289,"correct":22},"271kW",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":292,"answer":24,"analysis":33},875688,[293,295,297,299],{"key":20,"text":294,"correct":22},"38kg\u002Fh",{"key":24,"text":296,"correct":32},"41kg\u002Fh",{"key":27,"text":298,"correct":22},"46kg\u002Fh",{"key":30,"text":300,"correct":22},"48kg\u002Fh",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":303,"answer":27,"analysis":33},875689,[304,306,308,310],{"key":20,"text":305,"correct":22},"1332～1333kJ\u002Fkg",{"key":24,"text":307,"correct":22},"1134～1135kJ\u002Fkg",{"key":27,"text":309,"correct":32},"1098～1099kJ\u002Fkg",{"key":30,"text":311,"correct":22},"1062～1063kJ\u002Fkg",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":30,"analysis":33},875690,"2台相同的风机盘管并联工作，当1台风机盘管的控温电动阀关闭时，该段并联管路的综合阻力数S值是原来的( )。",[316,318,320,322],{"key":20,"text":317,"correct":22},"50%",{"key":24,"text":319,"correct":22},"100%",{"key":27,"text":321,"correct":22},"200%",{"key":30,"text":323,"correct":32},"400%",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":30,"analysis":33},875691,"一空调建筑空调水系统的供冷量为1000kW，冷水供回水温差为5℃，水的比热容为4.18kJ\u002F(kg·K)，设计工况的水泵扬程为27m，对应的效率为70%，在设计工况下，水泵的轴功率为下列哪一项？( )",[328,330,332,334],{"key":20,"text":329,"correct":22},"10～13kW",{"key":24,"text":331,"correct":22},"13.1～15kW",{"key":27,"text":333,"correct":22},"15.1～17kW",{"key":30,"text":335,"correct":32},"17.1～19kW",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":24,"analysis":33},875692,"某空调房间工作区高度为2m，设置侧送风口，风口下边距顶棚0，4m，射流实际射程要求6m，为使送风射流不致波及工作区，则房间最小高度为( )。",[340,342,344,346],{"key":20,"text":341,"correct":22},"2.86m",{"key":24,"text":343,"correct":32},"3.12m",{"key":27,"text":345,"correct":22},"3.24m",{"key":30,"text":347,"correct":22},"4.00m",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":24,"analysis":33},875693,"某工厂现有理化楼的化验室排放有害气体甲苯，其排气简的高度为12m，试问符合国家二级排放标准的最高允许排放速率接近下列哪一项？( )",[352,354,356,358],{"key":20,"text":353,"correct":22},"1.98kg\u002Fh",{"key":24,"text":355,"correct":32},"2.3kg\u002Fh",{"key":27,"text":357,"correct":22},"3.11kg\u002Fh",{"key":30,"text":359,"correct":22},"3.6kg\u002Fh",{"id":361,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":362,"answer":20,"analysis":33},875694,[363,364,365,366],{"key":20,"text":33,"correct":32},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":30,"text":33,"correct":22},{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":369,"answer":24,"analysis":33},875695,[370,371,372,373],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":32},{"key":27,"text":33,"correct":22},{"key":30,"text":33,"correct":22},{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":376,"answer":27,"analysis":33},875696,[377,379,381,383],{"key":20,"text":378,"correct":22},"1020～1030kW",{"key":24,"text":380,"correct":22},"970～980kW",{"key":27,"text":382,"correct":32},"960～970kW",{"key":30,"text":384,"correct":22},"940～950kW",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":20,"analysis":33},875697,"某酒店采用太阳能+电辅助加热的中央热水系统。已知，全年日平均用热负荷为2600kW·h，该地可用太阳能的时间为290d，同时，其日辅助电加热量为日平均用热负荷的20%，其余时间均采用电加热器加热。为了节能，拟采用热泵热水机组取代电加热器，满足使用功能的条件下，机组制热COP=4.60。利用太阳能时，若不计循环热水泵耗电量以及热损失，新方案的年节电量应是下列哪一项？( )",[389,391,393,395],{"key":20,"text":390,"correct":32},"250000～325000kW·h",{"key":24,"text":392,"correct":22},"325500～327500kW·h",{"key":27,"text":394,"correct":22},"328000～330000kW·h",{"key":30,"text":396,"correct":22},"330500～332500kW·h",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":399,"answer":30,"analysis":33},875698,[400,402,404,406],{"key":20,"text":401,"correct":22},"226～230kW",{"key":24,"text":403,"correct":22},"220～226kW",{"key":27,"text":405,"correct":22},"208～214kW",{"key":30,"text":407,"correct":32},"200～207kW",{"id":409,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":410,"answer":27,"analysis":33},875699,[411,413,415,417],{"key":20,"text":412,"correct":22},"采用公称外径为De40的PP-R管，符合规范规定",{"key":24,"text":414,"correct":22},"采用公称外径为De32的PP-R管，符合规范规定",{"key":27,"text":416,"correct":32},"采用公称外径为De20的PP-R管，符合规范规定",{"key":30,"text":418,"correct":22},"采用公称外径为De20的PP-R管，不符合规范规定",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":421,"answer":30,"analysis":33},875700,[422,424,426,428],{"key":20,"text":423,"correct":22},"90m",{"key":24,"text":425,"correct":22},"84m",{"key":27,"text":427,"correct":22},"72m",{"key":30,"text":429,"correct":32},"54m",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":20,"analysis":33},875701,"含有S02有害气体的流量为3000m3\u002Fh，其中S02的浓度为5.25mg\u002Fm3，采用固定床活性炭吸附装置净化该有害气体。设平衡吸附量为0.15kg\u002Fkg炭，吸附效率为96%。如有效使用时间(穿透时间)为250h，所需装炭量为下列哪一项？",[434,436,438,440],{"key":20,"text":435,"correct":32},"71.5～72.5kg",{"key":24,"text":437,"correct":22},"72.6～73.6kg",{"key":27,"text":439,"correct":22},"73.7～74.7kg",{"key":30,"text":441,"correct":22},"74.8～78.8kg",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":24,"analysis":33},875702,"某小区采用低压天然气管道供气，已知：小区住户的低压燃具额定压力为2500Pa，则从调压站到最远燃具的管道允许阻力损失应是( )Pa。",[446,448,450,452],{"key":20,"text":447,"correct":22},"2500",{"key":24,"text":449,"correct":32},"2025",{"key":27,"text":451,"correct":22},"1875",{"key":30,"text":453,"correct":22},"1500",{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":456,"answer":20,"analysis":33},875703,[457,459,461,462],{"key":20,"text":458,"correct":32},"3237",{"key":24,"text":460,"correct":22},"2000",{"key":27,"text":447,"correct":22},{"key":30,"text":463,"correct":22},"2800",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":27,"analysis":33},875704,"某设在地下室的燃油锅炉房长20m，宽10m，高6m，正常换气量最小可以为( )。",[468,469,470,471],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":32},{"key":30,"text":33,"correct":22},{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":27,"analysis":33},875705,"某30万㎡的小区，节能改造，室外供热水管道保温，用玻璃棉管壳[保温层平均使用温度k=60℃时，导热系数为0.034W／(m·K)]代替原来用的150mm厚的水泥膨胀珍珠岩[导热系数为0.16W／(m·K)]，且供回水温由95／70℃变为130\u002F70℃，地沟内温度为40℃，那么改造后的D325×8管道的保温材料厚度应为下列哪一项？",[476,478,480,482],{"key":20,"text":477,"correct":22},"30mm",{"key":24,"text":479,"correct":22},"40mm",{"key":27,"text":481,"correct":32},"50mm",{"key":30,"text":483,"correct":22},"60mm",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":30,"analysis":33},875706,"某房间室内温度为32℃，相对湿度为70%，房间内有明敷无保温的钢质给水管，大气压力为标准大气压，给水管表面不产生结露的给水温度应为( )℃。(给水管壁的热阻忽略不计)",[488,490,492,494],{"key":20,"text":489,"correct":22},"23",{"key":24,"text":491,"correct":22},"24",{"key":27,"text":493,"correct":22},"25",{"key":30,"text":495,"correct":32},"26",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":498,"answer":24,"analysis":33},875707,[499,501,503,505],{"key":20,"text":500,"correct":22},"Ⅰ型",{"key":24,"text":502,"correct":32},"Ⅱ型",{"key":27,"text":504,"correct":22},"Ⅲ型",{"key":30,"text":506,"correct":22},"Ⅳ型",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":27,"analysis":33},875708,"某通风系统的过滤器，可选择静电过滤器或袋式过滤器。已知：大气压为101.3kPa，空气温度为20℃。处理风量为3000m3\u002Fh，静电过滤器阻力为20Pa，耗电功率为20W；袋式过滤器阻力为120Pa。风机的全压效率为0.80，风机采用三角皮带传动(滚动轴承)。系统每年运行180天，每天运行10h。若不计电机的功率损耗，试从节能角度比较，静电过滤器比袋式过滤器年节电数值应是下列哪一项？",[511,513,515,517],{"key":20,"text":512,"correct":22},"110～125kWh",{"key":24,"text":514,"correct":22},"140～155kWh",{"key":27,"text":516,"correct":32},"160～185kWh",{"key":30,"text":518,"correct":22},"195～210kWh",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":521,"answer":30,"analysis":33},875709,[522,523,524,525],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":27,"text":33,"correct":22},{"key":30,"text":33,"correct":32},{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":528,"answer":30,"analysis":33},875710,[529,531,533,535],{"key":20,"text":530,"correct":22},"15℃",{"key":24,"text":532,"correct":22},"16℃",{"key":27,"text":534,"correct":22},"34℃",{"key":30,"text":536,"correct":32},"36℃",{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":30,"analysis":33},875711,"某热水锅炉，进水温度为60℃(比焓251.5kJ\u002Fkg)，出水温度为80℃(比焓335.5kJ\u002Fkg)，测定的循环流量为120t\u002Fh，压力为4MPa。锅炉每小时燃煤量为0.66t，燃煤的低位发热量为19000kJ\u002Fkg，锅炉热效率为( )。",[541,543,545,547],{"key":20,"text":542,"correct":22},"75.6%～76.6%",{"key":24,"text":544,"correct":22},"66.8%～68.8%",{"key":27,"text":546,"correct":22},"84.7%～85.2%",{"key":30,"text":548,"correct":32},"79.0%～80.8%",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":551,"answer":30,"analysis":33},875712,[552,554,556,558],{"key":20,"text":553,"correct":22},"16.5℃，12℃",{"key":24,"text":555,"correct":22},"18.5℃，12.5℃",{"key":27,"text":557,"correct":22},"20.5℃，13℃",{"key":30,"text":559,"correct":32},"21.2℃，13.5℃",[561,564,567,570,573,576],{"id":15,"name":562,"category":7,"favorite":563},"领导干部任职前廉政法规知识测试题",92,{"id":565,"name":566,"category":7,"favorite":15},595,"建筑结构与设备",{"id":568,"name":569,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":571,"name":572,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":574,"name":575,"category":7,"favorite":8},534,"BIM工程师",{"id":577,"name":575,"category":7,"favorite":8},535]