[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-564-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":571},{"id":5,"name":6,"category":7,"favorite":8},564,"专业案例（暖通空调专业）","建筑工程",0,3,50,477,[13,33,45,56,67,79,91,103,114,125,136,148,159,171,183,195,206,214,221,232,244,256,268,280,288,296,307,319,331,343,355,366,377,389,401,413,425,437,449,457,469,476,488,496,508,519,530,541,548,559],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":17},875563,1,"单选题","",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","8",false,{"key":24,"text":25,"correct":26},"B","9",true,{"key":28,"text":29,"correct":22},"C","10",{"key":31,"text":32,"correct":22},"D","11",{"id":34,"libraryId":5,"type":15,"typeLabel":16,"stem":35,"options":36,"answer":31,"analysis":17},875564,"洁净度等级为5级的洁净室，面积为81㎡，用≥0.5μm粒径粒子检测，测点个数为9，采样点的单次最小采样量应为( )。",[37,39,41,43],{"key":20,"text":38,"correct":22},"0.5L",{"key":24,"text":40,"correct":22},"1.0L",{"key":28,"text":42,"correct":22},"2.83L",{"key":31,"text":44,"correct":26},"5.68L",{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":47,"answer":28,"analysis":17},875565,[48,50,52,54],{"key":20,"text":49,"correct":22},"200h",{"key":24,"text":51,"correct":22},"210h",{"key":28,"text":53,"correct":26},"220h",{"key":31,"text":55,"correct":22},"230h",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":58,"answer":24,"analysis":17},875566,[59,61,63,65],{"key":20,"text":60,"correct":22},"132%",{"key":24,"text":62,"correct":26},"143%",{"key":28,"text":64,"correct":22},"154%",{"key":31,"text":66,"correct":22},"160%",{"id":68,"libraryId":5,"type":15,"typeLabel":16,"stem":69,"options":70,"answer":24,"analysis":17},875567,"北京某住宅区设置燃气锅炉房给小区供暖，供暖设计热负荷为6.7MW，管网热损失及锅炉房自用系数为1.2，锅炉房容量和台数设计合理的是( )。",[71,73,75,77],{"key":20,"text":72,"correct":22},"选2台额定热功率为4.2MW的热水锅炉",{"key":24,"text":74,"correct":26},"选3台额定热功率为2.8MW的热水锅炉",{"key":28,"text":76,"correct":22},"选1台额定热功率为8.4MW的热水锅炉",{"key":31,"text":78,"correct":22},"选2台额定热功率为5.6MW的热水锅炉",{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":24,"analysis":17},875568,"某实验室为空调房间，为节约能耗，采用送风式通风柜，补风取自相邻房间。通风柜柜内进行有毒污染物实验，柜内有毒污染物气体发生量为0.2m3\u002Fh，通风柜工作孔面积0.2㎡，则通风柜的最小补风量应是下列哪一项？",[83,85,87,89],{"key":20,"text":84,"correct":22},"500～600m3\u002Fh",{"key":24,"text":86,"correct":26},"680～740m3\u002Fh",{"key":28,"text":88,"correct":22},"750～850m3\u002Fh",{"key":31,"text":90,"correct":22},"1000～1080m3\u002Fh",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":24,"analysis":17},875569,"已知一台通风兼排烟双速离心风机，低速时风机铭牌风量为12450m3／h，风压为431Pa。已知当地的大气压力为B=101.3kPa，现要求高温时排风量为17430m3／h，排气温度为270℃，若风机、电机及传动效率在内的风机总效率为0.52，求该配套风机的电机功率至少应为多少？",[95,97,99,101],{"key":20,"text":96,"correct":22},"4kW",{"key":24,"text":98,"correct":26},"5.5kW",{"key":28,"text":100,"correct":22},"11kW",{"key":31,"text":102,"correct":22},"15kW",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":105,"answer":20,"analysis":17},875570,[106,108,110,112],{"key":20,"text":107,"correct":26},"28.6%",{"key":24,"text":109,"correct":22},"37.5%",{"key":28,"text":111,"correct":22},"40%",{"key":31,"text":113,"correct":22},"25%",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":116,"answer":28,"analysis":17},875571,[117,119,121,123],{"key":20,"text":118,"correct":22},"3组，75片",{"key":24,"text":120,"correct":22},"4组，76片",{"key":28,"text":122,"correct":26},"4组，80片",{"key":31,"text":124,"correct":22},"11组，77片",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":127,"answer":28,"analysis":17},875572,[128,130,132,134],{"key":20,"text":129,"correct":22},"1400～1490W\u002F(㎡·℃)",{"key":24,"text":131,"correct":22},"1500～1590W\u002F(㎡·℃)",{"key":28,"text":133,"correct":26},"1600～1690W\u002F(㎡·℃)",{"key":31,"text":135,"correct":22},"1700～1790W\u002F(㎡·℃)",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":31,"analysis":17},875573,"一溴化锂吸收式制冷机，发生器的放气范围为0.05，循环倍率为13，若进入发生器的稀溶液流量为6.448kg\u002Fs，则该发生器浓溶液浓度及产生的水蒸气流量是( )。",[140,142,144,146],{"key":20,"text":141,"correct":22},"0.70，83.824kg\u002Fs",{"key":24,"text":143,"correct":22},"0.70，0.650kg\u002Fs",{"key":28,"text":145,"correct":22},"0.70，0.499kg\u002Fs",{"key":31,"text":147,"correct":26},"0.65，0.499kg\u002Fs",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":150,"answer":24,"analysis":17},875574,[151,153,155,157],{"key":20,"text":152,"correct":22},"0.0171～0.0190",{"key":24,"text":154,"correct":26},"0.0191～0.0210",{"key":28,"text":156,"correct":22},"0.0211～0.0230",{"key":31,"text":158,"correct":22},"0.0236～0.0270",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":28,"analysis":17},875575,"某建筑采暖用低温热水地板辐射采暖系统，设计采暖供回水温度为60\u002F50℃，计算阻力损失为50kPa(其中最不利环路阻力损失为25kPa)。现采暖供回水温度调整为50\u002F42℃，系统和辐射地板加热的管径均不变，但需要调整辐射地板的布管，形成最不利的环路阻力损失为30kPa。热力入口的供回水压差应为下列哪一项？",[163,165,167,169],{"key":20,"text":164,"correct":22},"45～50kPa",{"key":24,"text":166,"correct":22},"51～60kPa",{"key":28,"text":168,"correct":26},"61～70kPa",{"key":31,"text":170,"correct":22},"71～80kPa",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":31,"analysis":17},875576,"某6层办公楼，采用散热器供暖，层高3.6m，南外墙热负荷243W，外窗热负荷490W，窗缝渗入冷风热负荷205W，南向修正为-15%。该房间散热器耗热量为( )。",[175,177,179,181],{"key":20,"text":176,"correct":22},"920～940W",{"key":24,"text":178,"correct":22},"890～910W",{"key":28,"text":180,"correct":22},"860～880W",{"key":31,"text":182,"correct":26},"810～830W",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":20,"analysis":17},875577,"某建筑物拟采用冰蓄冷空调系统，选择部分蓄冰方式。已知：电价谷段时间为23：00-7：00；制冷机白天空调时段运行8h；采用三级离心制冷机，其制冰时的制冷能力变化率为0.75；设计日空调最大小时冷负荷为22293kW，设计日空调运行15h，平均负荷系数取0.80按平均法估算的该空调系统设计日总冷负荷、按部分蓄冰方式蓄冷时制冷机标定制冷量、蓄冷装置有效容量分别为( )kW·h。",[187,189,191,193],{"key":20,"text":188,"correct":26},"267516，19108，114618",{"key":24,"text":190,"correct":22},"334395，23885，143310",{"key":28,"text":192,"correct":22},"267516，16720，100320",{"key":31,"text":194,"correct":22},"267516，19108，152846",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":197,"answer":24,"analysis":17},875578,[198,200,202,204],{"key":20,"text":199,"correct":22},"34.2～34.8℃",{"key":24,"text":201,"correct":26},"34.9～35.6℃",{"key":28,"text":203,"correct":22},"35.7～36.4℃",{"key":31,"text":205,"correct":22},"36.5～37.2℃",{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":24,"analysis":17},875579,"严寒地区某住宅小区，有一冬季供暖用热水锅炉房，容量为140MW，原供热范围为200万㎡的既有住宅，经对既有住宅进行围护结构节能改造后，供暖热指标降至48W\u002F㎡。试问，既有住宅改造后，该锅炉房还可负担新建住宅供暖的面积应是下列哪一项？(锅炉房自用负荷可忽略不计，管网为直埋，散热损失附加系数为0.10；新建住宅供暖热指标为40W\u002F㎡)( )",[210,211,212,213],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":26},{"key":28,"text":17,"correct":22},{"key":31,"text":17,"correct":22},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":216,"answer":24,"analysis":17},875580,[217,218,219,220],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":26},{"key":28,"text":17,"correct":22},{"key":31,"text":17,"correct":22},{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":223,"answer":24,"analysis":17},875581,[224,226,228,230],{"key":20,"text":225,"correct":22},"311.5Pa",{"key":24,"text":227,"correct":26},"467.2Pa",{"key":28,"text":229,"correct":22},"934.4Pa",{"key":31,"text":231,"correct":22},"0Pa",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":28,"analysis":17},875582,"某洁净室在新风管道上安装了粗效、中效和亚高效过滤器，对0.5μm以上的粒子的总效率为99%，回风部分安装的亚高效过滤器对0.5μm以上的粒子的效率为97%，新风和回风混合后经过高效过滤器，过滤器对0.5μm以上粒子的效率为99.9%，已知室外新风中大于0.5μm以上粒子总数为106粒\u002FL，回风中大于0.5μm以上粒子总数为3.5粒L，新回风比为1：4，高效过滤器出口大于0.5μm以上粒子浓度为下列哪一项？( )",[236,238,240,242],{"key":20,"text":237,"correct":22},"9～15粒\u002FL",{"key":24,"text":239,"correct":22},"4～8粒\u002FL",{"key":28,"text":241,"correct":26},"1～3粒\u002FL",{"key":31,"text":243,"correct":22},"＜1粒\u002FL",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":20,"analysis":17},875583,"某房间室内设计温度为20℃，相对湿度为60%，北面与室内温度为5℃的非供暖房间相邻，隔墙的面积为15㎡，传热系数为2W\u002F(㎡·℃)，表面传热系数为8W\u002F(㎡·℃)，该房间北面隔墙表面温度为多少？是否结露？( )",[248,250,252,254],{"key":20,"text":249,"correct":26},"16～17℃，不结露",{"key":24,"text":251,"correct":22},"16～17℃，结露",{"key":28,"text":253,"correct":22},"11～12℃，不结露",{"key":31,"text":255,"correct":22},"11～12℃，结露",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":24,"analysis":17},875584,"某车间的内区室内空气设计计算参数为：干球温度20℃，相对湿度60%，湿负荷为零，交付运行后，发热设备减少了，实际室内空调冷负荷比设计时减少了30%，在送风量和送风状态不变(送风相对湿度为90%)的情况下，室内空气状态应是下列哪一项？(该车间所在地为标准大气压，计算时不考虑围护结构的传热)( )",[260,262,264,266],{"key":20,"text":261,"correct":22},"16.5～17.5℃，相对湿度60%～70%",{"key":24,"text":263,"correct":26},"18.0～18.9℃，相对湿度65%～68%",{"key":28,"text":265,"correct":22},"37.5～38.5kJ\u002Fkg，含湿量为8.9～9.1g\u002Fkg",{"key":31,"text":267,"correct":22},"42.9～43.1kJ\u002Fkg，含湿量为7.5～8.0g\u002Fkg",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":24,"analysis":17},875585,"某空调系统供热负荷为1500kW，系统热媒为60℃\u002F50℃的热水，外网热媒为95℃\u002F70℃的热水，拟采用板式换热器进行换热，其传热系数为4000W\u002F(㎡·℃)，污垢系数为0.7，换热器面积应为( )。",[272,274,276,278],{"key":20,"text":273,"correct":22},"18～19㎡",{"key":24,"text":275,"correct":26},"19.5～20.5㎡",{"key":28,"text":277,"correct":22},"21～22㎡",{"key":31,"text":279,"correct":22},"22.5～23.5㎡",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":28,"analysis":17},875586,"某高层写字楼地下1层内走道长65m，宽2m，与走道相通的房间总面积800㎡，其中无窗房间面积300㎡，设固定窗房间面积100㎡，设可开启外窗房间面积400㎡。欲设1个机械排烟系统，在不考虑划分防烟分区的情况下其排烟风量最小为( )。",[284,285,286,287],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":28,"text":17,"correct":26},{"key":31,"text":17,"correct":22},{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":31,"analysis":17},875587,"五层办公楼，采用散热器采暖，层高3.6m，南外墙热负荷为243W，外窗热负荷为490W，窗缝渗入205W，南方向修正为-15%。求该房间散热器耗热量。",[292,293,294,295],{"key":20,"text":176,"correct":22},{"key":24,"text":178,"correct":22},{"key":28,"text":180,"correct":22},{"key":31,"text":182,"correct":26},{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":298,"answer":28,"analysis":17},875588,[299,301,303,305],{"key":20,"text":300,"correct":22},"460～480kPa",{"key":24,"text":302,"correct":22},"560～580kPa",{"key":28,"text":304,"correct":26},"270～280kPa",{"key":31,"text":306,"correct":22},"350～360kPa",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":20,"analysis":17},875589,"某冷库的冷藏肉类的冷藏间，货物品类为猪肉，生产旺月为6月，当地夏季空调日平均温度为29℃，采用纸板类包装。入库货物温度为-15℃，比焓为12.14kJ\u002Fkg；降温时间为24h，终止降温货物温度为-18℃，比焓为4.61kJ\u002Fkg；日进货量12000kg\u002Fd。该冷藏间的货物热流量为( )。",[311,313,315,317],{"key":20,"text":312,"correct":26},"1.90～2.00kW",{"key":24,"text":314,"correct":22},"2.00～2.10kW",{"key":28,"text":316,"correct":22},"2.10～2.20kW",{"key":31,"text":318,"correct":22},"2.20～2.30kW",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":20,"analysis":17},875590,"将质量浓度为0.02mg\u002Fm3的汞蒸气(分子量为200)换算为体积浓度mL\u002Fm3(ppm)，下列哪一项浓度值为正确？",[323,325,327,329],{"key":20,"text":324,"correct":26},"0.002～0.003mL\u002Fm3",{"key":24,"text":326,"correct":22},"0.08～0.09mL\u002Fm3",{"key":28,"text":328,"correct":22},"0.01～0.02mL\u002Fm3",{"key":31,"text":330,"correct":22},"890～900mL\u002Fm3",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":24,"analysis":17},875591,"某蒸气压缩机制冷理论循环的冷凝温度为30℃，蒸发温度为-15℃，热力完善度为0.8，若制冷量为30kW，则冷凝负荷为( )。",[335,337,339,341],{"key":20,"text":336,"correct":22},"30kW",{"key":24,"text":338,"correct":26},"36.5kW",{"key":28,"text":340,"correct":22},"8.4kW",{"key":31,"text":342,"correct":22},"35.2kW",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":24,"analysis":17},875592,"北京地区某办公楼的外墙内加气泡沫混凝土的厚度，按《公共建筑节能设计标准》GB50189-2005计算比按《采暖通风与空气调节设计规范》GB50019-2003计算需要加量，为下列何值？已知：建筑体形系数为0.3，墙体其他材料的热阻为0.l㎡·℃\u002FW，D＞6，北京地区采暖室外计算温度为-9℃，加气泡沫混凝土的导热系数λ=0.22W\u002F(m·℃)。",[347,349,351,353],{"key":20,"text":348,"correct":22},"210～240mm",{"key":24,"text":350,"correct":26},"250～270mm",{"key":28,"text":352,"correct":22},"18～200mm",{"key":31,"text":354,"correct":22},"280～300mm",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":357,"answer":24,"analysis":17},875593,[358,360,362,364],{"key":20,"text":359,"correct":22},"0.86～0.87",{"key":24,"text":361,"correct":26},"0.84～0.85",{"key":28,"text":363,"correct":22},"0.82～0.83",{"key":31,"text":365,"correct":22},"＞0.87",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":368,"answer":31,"analysis":17},875594,[369,371,373,375],{"key":20,"text":370,"correct":22},"4片",{"key":24,"text":372,"correct":22},"3片",{"key":28,"text":374,"correct":22},"2片",{"key":31,"text":376,"correct":26},"1片",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":20,"analysis":17},875595,"某旋风除尘器阻力系数为9.8，进口流速为12m\u002Fs，当气体温度为80℃，当地大气压为85kPa时，它的压力损失为( )。",[381,383,385,387],{"key":20,"text":382,"correct":26},"592Pa",{"key":24,"text":384,"correct":22},"850Pa",{"key":28,"text":386,"correct":22},"1000Pa",{"key":31,"text":388,"correct":22},"1200Pa",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":28,"analysis":17},875596,"低温热水地面辐射供暖系统的单位地面面积的散热量与地面面层材料有关，当设计供／回水温度为60\u002F50℃，室内空气温度为16℃时，地面面层分别为陶瓷地砖与木地板，采用公称外径为De20的PB管，加热管间距为200mm，填充层厚度为50mm，聚苯乙烯绝热层厚度为20mm，陶瓷地砖(热阻R=O.02㎡？K\u002FW)与木地板(热阻R=0.1㎡·K\u002FW)的单位地面面积的散热量之比，应是下列何项？( )。",[393,395,397,399],{"key":20,"text":394,"correct":22},"1.70～1.79",{"key":24,"text":396,"correct":22},"1.60～1.69",{"key":28,"text":398,"correct":26},"1.40～1.49",{"key":31,"text":400,"correct":22},"1.30～1.39",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":28,"analysis":17},875597,"某冷水系统有2台同型号的冷水机组，已知机组在100%负荷时的COP为5.7，50%负荷时的COP为6.7，当系统的负荷正好等于1台机组的额定负荷时，2台机组同时运行相对于1台机组运行的供冷节能率为( )。",[405,407,409,411],{"key":20,"text":406,"correct":22},"5%",{"key":24,"text":408,"correct":22},"10%",{"key":28,"text":410,"correct":26},"15%",{"key":31,"text":412,"correct":22},"18%",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":24,"analysis":17},875598,"某严寒地区办公建筑，采用普通机械排风系统，风机与电机采用直联方式，设计工况下的风机效率为60%，电机效率为90%，风道单位长度的平均阻力为3Pa\u002Fm(包括局部阻力和摩擦阻力)。该系统符合节能要求，允许的最大风管长度为下列哪一项？",[417,419,421,423],{"key":20,"text":418,"correct":22},"195～20lm",{"key":24,"text":420,"correct":26},"204～210m",{"key":28,"text":422,"correct":22},"220～240m",{"key":31,"text":424,"correct":22},"300～350m",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":28,"analysis":17},875599,"某乙类厂房，冬季工作区供暖计算温度15℃，厂房围护结构耗热量Q=313.1kW，厂房全面排风量L=42000m3\u002Fh；厂房采用集中热风采暖系统，设计送风量G=12kg\u002Fs，则该系统冬季的设计送风温度tjj应为下列何项？(注：当地标准大气压力，室内外空气密度取均为1.2kg\u002Fm3，空气比热容cp=1.011kj\u002F(kg·℃)，冬季通风室外计算温度-10℃)",[429,431,433,435],{"key":20,"text":430,"correct":22},"40～41.9℃",{"key":24,"text":432,"correct":22},"42～43.9℃",{"key":28,"text":434,"correct":26},"44～45.9℃",{"key":31,"text":436,"correct":22},"46～48.9℃",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":28,"analysis":17},875600,"某工厂通风系统，采用矩形薄钢板风管(管壁粗糙度为0.15mm)尺寸为a·b=210mm×190mm，在夏季测得管内空气流速v=12m\u002Fs，温度t=100℃，该风管的单位长度摩擦压力损失为下列哪一项？(已知：当地大气压力为80.80kPa，要求按流速查相关图表计算，不需要进行空气密度和黏度修正)( )",[441,443,445,447],{"key":20,"text":442,"correct":22},"7.4～7.6Pa\u002Fm",{"key":24,"text":444,"correct":22},"7.1～7.3Pa\u002Fm",{"key":28,"text":446,"correct":26},"5.7～6.0Pa\u002Fm",{"key":31,"text":448,"correct":22},"5.3～5.6Pa\u002Fm",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":31,"analysis":17},875601,"某水冷离心式冷水机组，设计工况下的制冷量为500kW，COP为5.0，冷却水进出水温差为5℃。采用横流型冷却塔，冷却塔设在裙房屋面，其集水盘水面与机房内冷却水泵的高差为18m。冷却塔喷淋口距离冷却水集水盘水面的高差为5m，喷淋口出水压力为2m，冷却水管路总阻力为5m，冷凝器水阻力为8m。忽略冷却水泵及冷凝水管与环境换热对冷凝负荷的影响。冷却水泵的扬程和流量(不考虑安全系数)为( )。",[453,454,455,456],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":28,"text":17,"correct":22},{"key":31,"text":17,"correct":26},{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":24,"analysis":17},875602,"一栋10层办公楼，采用风机盘管+新风的空调方案，每层设置1台新风机组，全楼共有风机盘管360台，在工程验收时，空调设备抽检的台数为( )。",[461,463,465,467],{"key":20,"text":462,"correct":22},"1台新风机组和5台风机盘管",{"key":24,"text":464,"correct":26},"2台新风机组和36台风机盘管",{"key":28,"text":466,"correct":22},"3台新风机组和54台风机盘管",{"key":31,"text":468,"correct":22},"5台新风机组和72台风机盘管",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":471,"answer":28,"analysis":17},875603,[472,473,474,475],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":22},{"key":28,"text":17,"correct":26},{"key":31,"text":17,"correct":22},{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":31,"analysis":17},875604,"热水供热系统主干线比摩阻为60Pa\u002Fm，长度为2000m，局部阻力与沿程阻力的估算比值为0.6，热源内部损失为15m，最不利用户的内部阻力为5m，循环水泵的扬程不应小于( )。",[480,482,484,486],{"key":20,"text":481,"correct":22},"15m",{"key":24,"text":483,"correct":22},"19m",{"key":28,"text":485,"correct":22},"20m",{"key":31,"text":487,"correct":26},"39m",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":20,"analysis":17},875605,"有集中热水供应系统的18层普通高层住宅，每层8户，每户4人，1～4层为市政自来水直接供水，5～18层为低位贮水池、加压水泵和高位水箱供水，每户有低水箱冲落式坐便器、淋浴器、热水器、洗手盆、洗涤盆、家用洗衣机各1个，小时变化系数和定额均取最小值，高位水箱的调节水量为( )(取整数)。",[492,493,494,495],{"key":20,"text":17,"correct":26},{"key":24,"text":17,"correct":22},{"key":28,"text":17,"correct":22},{"key":31,"text":17,"correct":22},{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":20,"analysis":17},875606,"某用户的供暖设计热负荷为150kW，设计供回水温度为85℃\u002F60℃，计算阻力损失为30kPa，其入口外网的实际供回水压差为50kPa，该用户的水力失调度应为( )。",[500,502,504,506],{"key":20,"text":501,"correct":26},"1.29",{"key":24,"text":503,"correct":22},"1.00",{"key":28,"text":505,"correct":22},"O.78",{"key":31,"text":507,"correct":22},"无法确定",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":510,"answer":20,"analysis":17},875607,[511,513,515,517],{"key":20,"text":512,"correct":26},"1800～1900",{"key":24,"text":514,"correct":22},"1900～2000",{"key":28,"text":516,"correct":22},"2000～2100",{"key":31,"text":518,"correct":22},"2100～2200",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":521,"answer":20,"analysis":17},875608,[522,524,526,528],{"key":20,"text":523,"correct":26},"5.6～5.8t\u002Fh",{"key":24,"text":525,"correct":22},"6.6～6.8t\u002Fh",{"key":28,"text":527,"correct":22},"7.6～7.8t\u002Fh",{"key":31,"text":529,"correct":22},"8.6～8.8t\u002Fh",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":532,"answer":31,"analysis":17},875609,[533,535,537,539],{"key":20,"text":534,"correct":22},"700",{"key":24,"text":536,"correct":22},"800",{"key":28,"text":538,"correct":22},"900",{"key":31,"text":540,"correct":26},"1000",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":543,"answer":24,"analysis":17},875610,[544,545,546,547],{"key":20,"text":17,"correct":22},{"key":24,"text":17,"correct":26},{"key":28,"text":17,"correct":22},{"key":31,"text":17,"correct":22},{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":550,"answer":20,"analysis":17},875611,[551,553,555,557],{"key":20,"text":552,"correct":26},"85",{"key":24,"text":554,"correct":22},"90",{"key":28,"text":556,"correct":22},"95",{"key":31,"text":558,"correct":22},"100",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":24,"analysis":17},875612,"某工程确定选用名义制冷量为200kW的螺杆式冷水机组，由生产厂家的样本查得：该机组在冷却水进口温度30℃，出口温度35℃时，冷凝温度为38℃；采用卧式壳管式冷凝器，传热系数为750W\u002F(㎡·K)，冷凝器排热量为232.8kW，水侧污垢热阻为0.086㎡·K\u002FkW。已知使用地点水质较差，污垢热阻为0.3㎡·K\u002FkW。使用当地水质时，壳管式冷凝器的传热系数是( )。",[563,565,567,569],{"key":20,"text":564,"correct":22},"712.0～713.0W\u002F(㎡·K)",{"key":24,"text":566,"correct":26},"646.0～647.0W\u002F(㎡·K)",{"key":28,"text":568,"correct":22},"574.0～575.0W\u002F(㎡·K)",{"key":31,"text":570,"correct":22},"448.0～449.0W\u002F(㎡·K)",[572,575,578,581,584,587],{"id":15,"name":573,"category":7,"favorite":574},"领导干部任职前廉政法规知识测试题",92,{"id":576,"name":577,"category":7,"favorite":15},595,"建筑结构与设备",{"id":579,"name":580,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":582,"name":583,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":585,"name":586,"category":7,"favorite":8},534,"BIM工程师",{"id":588,"name":586,"category":7,"favorite":8},535]