[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-564-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":518},{"id":5,"name":6,"category":7,"favorite":8},564,"专业案例（暖通空调专业）","建筑工程",0,2,50,477,[13,29,40,47,58,65,77,88,100,111,119,127,139,150,162,170,178,190,201,213,225,232,243,251,263,275,282,294,305,317,324,331,342,353,362,373,385,392,403,415,427,437,444,452,462,470,477,488,496,507],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":23,"analysis":17},875513,1,"单选题","",[19,22,25,27],{"key":20,"text":17,"correct":21},"A",false,{"key":23,"text":17,"correct":24},"B",true,{"key":26,"text":17,"correct":21},"C",{"key":28,"text":17,"correct":21},"D",{"id":30,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":31,"answer":23,"analysis":17},875514,[32,34,36,38],{"key":20,"text":33,"correct":21},"30mm",{"key":23,"text":35,"correct":24},"40mm",{"key":26,"text":37,"correct":21},"50mm",{"key":28,"text":39,"correct":21},"60mm",{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":42,"answer":20,"analysis":17},875515,[43,44,45,46],{"key":20,"text":17,"correct":24},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":21},{"key":28,"text":17,"correct":21},{"id":48,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":49,"answer":23,"analysis":17},875516,[50,52,54,56],{"key":20,"text":51,"correct":21},"82.5℃",{"key":23,"text":53,"correct":24},"73.5℃",{"key":26,"text":55,"correct":21},"80.4℃",{"key":28,"text":57,"correct":21},"86.0℃",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":60,"answer":26,"analysis":17},875517,[61,62,63,64],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":24},{"key":28,"text":17,"correct":21},{"id":66,"libraryId":5,"type":15,"typeLabel":16,"stem":67,"options":68,"answer":26,"analysis":17},875518,"北京某8层居住建筑体形系数为0.3，东南角房间的东向和南向各有-PVC塑钢外窗，窗高2m，东向窗墙面积比为0.35，南向窗墙面积比为0.5，玻璃的遮阳系数为0.93，外窗均设置伸出0.5m的水平外遮阳，下列哪个说法是正确的？( )",[69,71,73,75],{"key":20,"text":70,"correct":21},"窗墙面积比超过限值，应进行热工性能的权衡判断",{"key":23,"text":72,"correct":21},"南向外窗不应设置外遮阳",{"key":26,"text":74,"correct":24},"遮阳系数超过限值，应进行热工性能的权衡判断",{"key":28,"text":76,"correct":21},"不必进行热工性能的权衡判断",{"id":78,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":79,"answer":28,"analysis":17},875519,[80,82,84,86],{"key":20,"text":81,"correct":21},"15%",{"key":23,"text":83,"correct":21},"25%",{"key":26,"text":85,"correct":21},"35%",{"key":28,"text":87,"correct":24},"45%",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":20,"analysis":17},875520,"某建筑空调采用地埋管地源热泵，设计参数为制冷量2000kW。全年空调制冷当量满负荷运行时间为1000h，制热量为2500kW，全年空调供热当量满负荷运行时间为800h，设热泵机组的制冷、制热的能效比全年均为5.0，辅助冷却塔的冷却能力不随负荷变化，不计水泵等的附加散热量。要维持土壤全年自身热平衡(不考虑土壤与外界的换热)，下列哪一项措施是正确的？( )",[92,94,96,98],{"key":20,"text":93,"correct":24},"设置全年冷却能力为800000kW·h的辅助冷却塔",{"key":23,"text":95,"correct":21},"设置全年冷却能力为400000kW·h的辅助冷却塔",{"key":26,"text":97,"correct":21},"设置全年加热能力为400000kW·h的辅助供热设备",{"key":28,"text":99,"correct":21},"系统已能实现土壤全年热平衡，不需设置任何辅助设备",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":102,"answer":26,"analysis":17},875521,[103,105,107,109],{"key":20,"text":104,"correct":21},"1300kW",{"key":23,"text":106,"correct":21},"1350kW",{"key":26,"text":108,"correct":24},"1400kW",{"key":28,"text":110,"correct":21},"1650kW",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":26,"analysis":17},875522,"严寒地区办公楼，采用两管制定风量空调系统，空调机组内设置了预热盘管，空气经粗、中效两级过滤后送入房间，其风机全压为1280Pa，总效率为70%。关于风机的单位风量耗功率和是否满足节能设计标准的判断，下列正确的是哪一项( )。",[115,116,117,118],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":24},{"key":28,"text":17,"correct":21},{"id":120,"libraryId":5,"type":15,"typeLabel":16,"stem":121,"options":122,"answer":26,"analysis":17},875523,"SHL10-1.25-AII型锅炉，额定热效率为80%，燃料的低位发热量为25000kJ\u002Fkg，固体不完全燃烧热损失为10%，送风温度为20℃，锅炉送风量为( )。",[123,124,125,126],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":24},{"key":28,"text":17,"correct":21},{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":28,"analysis":17},875524,"某水平圆形热源(散热面直径B=l.Om)的对流散热量为Q=5.466kj\u002Fs，拟在热源上部1.0m处设直径为D=1.2m的圆伞形接受罩排除余热。设室内有轻微的横向气流干扰，则计算排风量应是下列何项？(罩口扩大面积的空气吸入流速v=0.5m\u002Fs)",[131,133,135,137],{"key":20,"text":132,"correct":21},"1001～1200m3\u002Fh",{"key":23,"text":134,"correct":21},"1201～1400m3\u002Fh",{"key":26,"text":136,"correct":21},"1401～1600m3\u002Fh",{"key":28,"text":138,"correct":24},"1601～1800m3\u002Fh",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":141,"answer":28,"analysis":17},875525,[142,144,146,148],{"key":20,"text":143,"correct":21},"24g\u002Fs",{"key":23,"text":145,"correct":21},"17～18g\u002Fs",{"key":26,"text":147,"correct":21},"11～12g\u002Fs",{"key":28,"text":149,"correct":24},"5～8g\u002Fs",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":28,"analysis":17},875526,"某有害气体流量为3000m3\u002Fh，其中有害物成分的浓度为5.25ppm，克摩尔数M=64，采用固定床活性炭吸附装置净化该有害气体，设平衡吸附量为0.15kg\u002Fkg，炭吸附效率为95%，一次装活性炭量为80kg，则连续有效使用时间为下列哪一项？",[154,156,158,160],{"key":20,"text":155,"correct":21},"200～225h",{"key":23,"text":157,"correct":21},"226～250h",{"key":26,"text":159,"correct":21},"251～270h",{"key":28,"text":161,"correct":24},"271～290h",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":23,"analysis":17},875527,"一层高6.5m的多层建筑物需设机械排烟房间的面积为105㎡，其排烟风机的风量不小于( )。",[166,167,168,169],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":24},{"key":26,"text":17,"correct":21},{"key":28,"text":17,"correct":21},{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":20,"analysis":17},875528,"某20层的民用建筑防烟楼梯间及其合用前室设置如压送风系统，下列做法中( )是可行的。",[174,175,176,177],{"key":20,"text":17,"correct":24},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":21},{"key":28,"text":17,"correct":21},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":23,"analysis":17},875529,"已知某外保温外墙的平均传热系数为0.55W\u002F(㎡·K)，冬季室外计算温度为-12℃，室内计算温度为18℃，保温层热阻为1.5㎡·K\u002FW，保温层内侧的温度约为( )。",[182,184,186,188],{"key":20,"text":183,"correct":21},"12.8℃",{"key":23,"text":185,"correct":24},"13.5℃",{"key":26,"text":187,"correct":21},"14.5℃",{"key":28,"text":189,"correct":21},"15.5℃",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":192,"answer":28,"analysis":17},875530,[193,195,197,199],{"key":20,"text":194,"correct":21},"11250",{"key":23,"text":196,"correct":21},"15000",{"key":26,"text":198,"correct":21},"18750",{"key":28,"text":200,"correct":24},"22280",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":20,"analysis":17},875531,"北京市某办公楼建筑面积为2000㎡，冬季采用空调供暖，室内设计温度为22℃，空调每天运行10h。空调供暖年耗热量为( )。",[205,207,209,211],{"key":20,"text":206,"correct":24},"500～630GJ",{"key":23,"text":208,"correct":21},"600～730GJ",{"key":26,"text":210,"correct":21},"700～830GJ",{"key":28,"text":212,"correct":21},"800～930GJ",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":26,"analysis":17},875532,"燃煤热水锅炉的流量为96t\u002Fh，进出水温度为70℃\u002F95℃，燃煤量为0.66t\u002Fh，煤的低位热值为19000kJ\u002Fkg，水的比热容取4.187kJ\u002F(kg·℃)，锅炉热效率的近似值为( )。",[217,219,221,223],{"key":20,"text":218,"correct":21},"0.70",{"key":23,"text":220,"correct":21},"0.75",{"key":26,"text":222,"correct":24},"0.80",{"key":28,"text":224,"correct":21},"0.90",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":227,"answer":26,"analysis":17},875533,[228,229,230,231],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":24},{"key":28,"text":17,"correct":21},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":234,"answer":23,"analysis":17},875534,[235,237,239,241],{"key":20,"text":236,"correct":21},"740～790W",{"key":23,"text":238,"correct":24},"800～850W",{"key":26,"text":240,"correct":21},"860～910W",{"key":28,"text":242,"correct":21},"920～960W",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":26,"analysis":17},875535,"战时为二等人员掩蔽所的人防地下室，地下室层高3m，主要出入口最小防毒通道面积2m×3.5m，人防清洁区长50m、宽10m，掩蔽人数400人，按人员最低标准设置滤毒通风新风量，总新风量为( )。",[247,248,249,250],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":24},{"key":28,"text":17,"correct":21},{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":20,"analysis":17},875536,"某北向房间外墙和外窗的基本耗热量为3500W，朝向修正率和风力附加率各为10%，冷风渗透耗热量为2000W，房间高度为5.5m，通过房间的热管道的有效稳定散热量为2000W，其供暖热负荷为( )。",[255,257,259,261],{"key":20,"text":256,"correct":24},"4326W",{"key":23,"text":258,"correct":21},"4366W",{"key":26,"text":260,"correct":21},"6326W",{"key":28,"text":262,"correct":21},"6366W",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":23,"analysis":17},875537,"某建筑供水系统，1～4层为外网直接供水，5～18层为高位水箱供水，由水泵从水池中抽取向水箱供水，每层住户3人，6个住户，每层有低水箱冲落式大便器、沐浴器、热水器、洗脸盆、洗涤盆、家用洗衣机，小时变化系数和定额均取最小值。问水箱调节水量为多少？",[267,269,271,273],{"key":20,"text":268,"correct":21},"1.0～1.3m3",{"key":23,"text":270,"correct":24},"1.5～1.8m3",{"key":26,"text":272,"correct":21},"2.0～2.3m3",{"key":28,"text":274,"correct":21},"2.4～2.9m3",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":277,"answer":28,"analysis":17},875538,[278,279,280,281],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":21},{"key":28,"text":17,"correct":24},{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":20,"analysis":17},875539,"某变制冷剂流量(VRV)系统，标准工况及配管情况下系统性能系数COP一2.7，而此系统最远末端超出额定配管长度为120m，吸气管平均阻力相当于0.06℃／m，液管平均阻力相当于0.03℃\u002Fm，问该系统满负荷时，系统的实际性能系数应为下列何值？注：蒸发温度增／降1℃，COP约增／降3%；冷凝温度增／降1℃，COP约降／增1.5%。",[286,288,290,292],{"key":20,"text":287,"correct":24},"＜1.9",{"key":23,"text":289,"correct":21},"1.9～2.O",{"key":26,"text":291,"correct":21},"2.1～2.2",{"key":28,"text":293,"correct":21},"＞2.2",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":296,"answer":28,"analysis":17},875540,[297,299,301,303],{"key":20,"text":298,"correct":21},"0.55～0.57m",{"key":23,"text":300,"correct":21},"0.61～0.63m",{"key":26,"text":302,"correct":21},"0.65～0.67m",{"key":28,"text":304,"correct":24},"0.69～0.70m",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":20,"analysis":17},875541,"某办公楼采用变风量空调系统，空调冷水系统为一级泵变流量系统，空调机组冷水管路上设置电动调节阀，采用1台变频水泵控制供回水总管的压差恒定。假设水泵的流量与频率呈正比关系，当水泵运行频率为40Hz时，水泵效率下降了10%，这时该水泵的能耗比工频时减少( )。",[309,311,313,315],{"key":20,"text":310,"correct":24},"11%",{"key":23,"text":312,"correct":21},"18%",{"key":26,"text":314,"correct":21},"32%",{"key":28,"text":316,"correct":21},"43%",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":319,"answer":23,"analysis":17},875542,[320,321,322,323],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":24},{"key":26,"text":17,"correct":21},{"key":28,"text":17,"correct":21},{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":326,"answer":23,"analysis":17},875543,[327,328,329,330],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":24},{"key":26,"text":17,"correct":21},{"key":28,"text":17,"correct":21},{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":333,"answer":20,"analysis":17},875544,[334,336,338,340],{"key":20,"text":335,"correct":24},"34～35℃",{"key":23,"text":337,"correct":21},"37～38℃",{"key":26,"text":339,"correct":21},"40～41℃",{"key":28,"text":341,"correct":21},"43～44℃",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":344,"answer":28,"analysis":17},875545,[345,347,349,351],{"key":20,"text":346,"correct":21},"用户1和用户3流量减小，室温降低",{"key":23,"text":348,"correct":21},"用户1和用户3下层房间室温比上层房间室温降得更低",{"key":26,"text":350,"correct":21},"用户1不同楼层房间的室温偏差比用户3小",{"key":28,"text":352,"correct":24},"用户1不同楼层房间的室温偏差比用户3大",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":23,"analysis":17},875546,"兰州某办公楼(形体系数为0.28的外墙)，按照《公共建筑节能设计标准》的规定进行改造，加贴膨胀聚苯板，原外墙为360mm黏土多孔砖[λ=O.58W\u002F(m·K)]，内衬灰20mm[λ=O.87W\u002F(m·K)]，则外墙所贴的膨胀聚苯板[λ=0.05W\u002F(m·K)]的厚度至少应选下列何值？",[357,358,359,360],{"key":20,"text":35,"correct":21},{"key":23,"text":37,"correct":24},{"key":26,"text":39,"correct":21},{"key":28,"text":361,"correct":21},"70mm",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":364,"answer":26,"analysis":17},875547,[365,367,369,371],{"key":20,"text":366,"correct":21},"43粒",{"key":23,"text":368,"correct":21},"119粒",{"key":26,"text":370,"correct":24},"161粒",{"key":28,"text":372,"correct":21},"259粒",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":28,"analysis":17},875548,"一栋楼的空调水系统参数如下：冷水机组的阻力为100kPa，过滤器、分集水器等管道附件的阻力为80kPa，管道为异程系统，最远环路的阻力最大，其单程长度100m，比摩阻均按120Pa\u002Fm估算，管道局部阻力为沿程阻力的50%，最远环路空调末端阻力为50kPa(包括阀门)，则循环水泵的扬程应为( )。",[377,379,381,383],{"key":20,"text":378,"correct":21},"20～25m",{"key":23,"text":380,"correct":21},"25～27m",{"key":26,"text":382,"correct":21},"27～29m",{"key":28,"text":384,"correct":24},"29～31m",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":387,"answer":20,"analysis":17},875549,[388,389,390,391],{"key":20,"text":17,"correct":24},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":21},{"key":28,"text":17,"correct":21},{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":394,"answer":26,"analysis":17},875550,[395,397,399,401],{"key":20,"text":396,"correct":21},"A机组",{"key":23,"text":398,"correct":21},"B机组",{"key":26,"text":400,"correct":24},"C机组",{"key":28,"text":402,"correct":21},"D机组",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":28,"analysis":17},875551,"北京某住宅楼顶层一卫生间面积为10㎡，卫生间洁具占2㎡，房间按对流方式计算的热负荷为800W，室内计算温度为18℃，卫生间采用低温热水地板辐射供暖，地板表面平均温度为( )。",[407,409,411,413],{"key":20,"text":408,"correct":21},"23～24℃",{"key":23,"text":410,"correct":21},"24～25℃",{"key":26,"text":412,"correct":21},"25～26℃",{"key":28,"text":414,"correct":24},"26～27℃",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":28,"analysis":17},875552,"某公共建筑的集中热水供暖的二次水系统，总热负荷为3200kW，供回水温度为95℃\u002F70℃，室外主干线总长1600m，如果选用联轴器连接的循环水泵时，水泵的设计工况点的轴功率计算值应是下列哪一项(取整数)？( )",[419,421,423,425],{"key":20,"text":420,"correct":21},"19kW",{"key":23,"text":422,"correct":21},"17kW",{"key":26,"text":424,"correct":21},"15kW",{"key":28,"text":426,"correct":24},"13kW",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":429,"answer":28,"analysis":17},875553,[430,431,433,435],{"key":20,"text":81,"correct":21},{"key":23,"text":432,"correct":21},"28%",{"key":26,"text":434,"correct":21},"42%",{"key":28,"text":436,"correct":24},"57%",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":439,"answer":28,"analysis":17},875554,[440,441,442,443],{"key":20,"text":155,"correct":21},{"key":23,"text":157,"correct":21},{"key":26,"text":159,"correct":21},{"key":28,"text":161,"correct":24},{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":26,"analysis":17},875555,"某建筑高度23m公共建筑的900㎡中庭，高度为20m，屋顶有可开启的天窗40㎡，机械排烟系统的最小排烟量为( )。",[448,449,450,451],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":24},{"key":28,"text":17,"correct":21},{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":454,"answer":23,"analysis":17},875556,[455,457,459,461],{"key":20,"text":456,"correct":21},"4kW",{"key":23,"text":458,"correct":24},"5.5kW",{"key":26,"text":460,"correct":21},"11kW",{"key":28,"text":424,"correct":21},{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":26,"analysis":17},875557,"某26层建筑的防烟楼梯间及其前室，有26个双扇疏散门，每层门的尺寸为2.0m×1.6m，采用金属风道，走道设机械排烟系统，前室不送风，防烟楼梯间加压送风量应选择( )。",[466,467,468,469],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":24},{"key":28,"text":17,"correct":21},{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":472,"answer":26,"analysis":17},875558,[473,474,475,476],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":24},{"key":28,"text":17,"correct":21},{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":479,"answer":20,"analysis":17},875559,[480,482,484,486],{"key":20,"text":481,"correct":24},"24～25kW",{"key":23,"text":483,"correct":21},"26～27kW",{"key":26,"text":485,"correct":21},"28～29kW",{"key":28,"text":487,"correct":21},"30～31kW",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":28,"analysis":17},875560,"民用高层建筑地下1层商店机械排烟系统的排烟风机负担2个防烟分区的排烟，面积分别为100㎡和80㎡，该排烟风机的排烟量可按( )考虑。",[492,493,494,495],{"key":20,"text":17,"correct":21},{"key":23,"text":17,"correct":21},{"key":26,"text":17,"correct":21},{"key":28,"text":17,"correct":24},{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":498,"answer":23,"analysis":17},875561,[499,501,503,505],{"key":20,"text":500,"correct":21},"20℃",{"key":23,"text":502,"correct":24},"22.9℃",{"key":26,"text":504,"correct":21},"27.3℃",{"key":28,"text":506,"correct":21},"29.5℃",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":509,"answer":23,"analysis":17},875562,[510,512,514,516],{"key":20,"text":511,"correct":21},"293",{"key":23,"text":513,"correct":24},"846",{"key":26,"text":515,"correct":21},"1060",{"key":28,"text":517,"correct":21},"3210",[519,522,525,528,531,534],{"id":15,"name":520,"category":7,"favorite":521},"领导干部任职前廉政法规知识测试题",92,{"id":523,"name":524,"category":7,"favorite":15},595,"建筑结构与设备",{"id":526,"name":527,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":529,"name":530,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":532,"name":533,"category":7,"favorite":8},534,"BIM工程师",{"id":535,"name":533,"category":7,"favorite":8},535]