[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-564-10":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":309},{"id":5,"name":6,"category":7,"favorite":8},564,"专业案例（暖通空调专业）","建筑工程",0,10,50,477,[13,34,41,52,63,71,82,94,103,114,125,136,148,159,170,181,193,205,217,229,241,248,260,271,278,289,301],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},875913,1,"单选题","某采用集中送风热风供暖的民用建筑房间长宽各为60m、高7m，送风口高度3.5m。可以采用的最少送风射流数量为( )。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","两侧平行对送，每侧2股射流",false,{"key":24,"text":25,"correct":26},"B","两侧平行对送，每侧3股射流",true,{"key":28,"text":29,"correct":22},"C","单侧平行送风，每侧2股射流",{"key":31,"text":32,"correct":22},"D","单侧平行送风，每侧3股射流","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":36,"answer":28,"analysis":33},875914,[37,38,39,40],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":22},{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":43,"answer":28,"analysis":33},875915,[44,46,48,50],{"key":20,"text":45,"correct":22},"0%～15%，达到水力平衡",{"key":24,"text":47,"correct":22},"16%～30%，达到水力平衡",{"key":28,"text":49,"correct":26},"31%～60%，达不到水力平衡",{"key":31,"text":51,"correct":22},"61%～80%，达不到水力平衡",{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":54,"answer":31,"analysis":33},875916,[55,57,59,61],{"key":20,"text":56,"correct":22},"2.10～2.30",{"key":24,"text":58,"correct":22},"1.75～1.95",{"key":28,"text":60,"correct":22},"1.36～1.46",{"key":31,"text":62,"correct":26},"1.15～1.35",{"id":64,"libraryId":5,"type":15,"typeLabel":16,"stem":65,"options":66,"answer":20,"analysis":33},875917,"有一酸性溶液槽，槽长A=1.2m，槽宽B=0.8m，溶液温度等于室温(常温)。设计采用E×F为250mm×250mm标准断面的双侧罩，当要求控制风速vx=0.3m\u002Fs时，总排风量为( )。",[67,68,69,70],{"key":20,"text":33,"correct":26},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":73,"answer":24,"analysis":33},875918,[74,76,78,80],{"key":20,"text":75,"correct":22},"1.0m",{"key":24,"text":77,"correct":26},"1.25m",{"key":28,"text":79,"correct":22},"1.5m",{"key":31,"text":81,"correct":22},"1.75m",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},875919,"供暖热水采用快速式水-水换热器，已知热媒侧供回水温度为110℃\u002F70℃，二次热水侧供回水温度为60℃\u002F50℃，一、二次水同向流动与一、二次水逆向流动的换热温差分别为( )。",[86,88,90,92],{"key":20,"text":87,"correct":22},"32.7℃，27.9℃",{"key":24,"text":89,"correct":22},"30.0℃，30.0℃",{"key":28,"text":91,"correct":26},"27.9℃，32.7℃",{"key":31,"text":93,"correct":22},"35.0℃，35.0℃",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":96,"answer":28,"analysis":33},875920,[97,99,101],{"key":20,"text":98,"correct":22},"9%～10%",{"key":24,"text":100,"correct":22},"6%～7%",{"key":28,"text":102,"correct":26},"4%～5%",{"id":104,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":105,"answer":28,"analysis":33},875921,[106,108,110,112],{"key":20,"text":107,"correct":22},"a+b+c",{"key":24,"text":109,"correct":22},"a+b",{"key":28,"text":111,"correct":26},"a+c",{"key":31,"text":113,"correct":22},"b+c",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":116,"answer":24,"analysis":33},875922,[117,119,121,123],{"key":20,"text":118,"correct":22},"5500～6000Pa",{"key":24,"text":120,"correct":26},"6500～7000Pa",{"key":28,"text":122,"correct":22},"7500～8000Pa",{"key":31,"text":124,"correct":22},"9500～10000Pa",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":127,"answer":28,"analysis":33},875923,[128,130,132,134],{"key":20,"text":129,"correct":22},"7～8m",{"key":24,"text":131,"correct":22},"8～9m",{"key":28,"text":133,"correct":26},"10～11m",{"key":31,"text":135,"correct":22},"11～12m",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":28,"analysis":33},875924,"某江水源热泵系统直接使用江水，江水取水点与用水点高度差为110m，供水水管长度为420m。单位长度的江水管道的平均沿程阻力与局部阻力损失之和为0.04m，江水源热泵换热器的阻力为4.5m。江水源热泵机组使用后的回水经过城市雨水管道回流到江中，不考虑取水及回水的头部损失，该江水源热泵的江水取水泵扬程应为( )。",[140,142,144,146],{"key":20,"text":141,"correct":22},"1.182～1.280MPa",{"key":24,"text":143,"correct":22},"1.281～1.358MPa",{"key":28,"text":145,"correct":26},"1.359～1.437MPa",{"key":31,"text":147,"correct":22},"1.438～1.476MPa",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":150,"answer":28,"analysis":33},875925,[151,153,155,157],{"key":20,"text":152,"correct":22},"第1种",{"key":24,"text":154,"correct":22},"第2种",{"key":28,"text":156,"correct":26},"第3种",{"key":31,"text":158,"correct":22},"第4种",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":161,"answer":31,"analysis":33},875926,[162,164,166,168],{"key":20,"text":163,"correct":22},"0.0134%",{"key":24,"text":165,"correct":22},"0.151%",{"key":28,"text":167,"correct":22},"0.01475%",{"key":31,"text":169,"correct":26},"0.0075%",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":172,"answer":24,"analysis":33},875927,[173,175,177,179],{"key":20,"text":174,"correct":22},"50级，M3.0级",{"key":24,"text":176,"correct":26},"50级，M3.2级",{"key":28,"text":178,"correct":22},"50级，M3.5级",{"key":31,"text":180,"correct":22},"50级，M3.7级",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":31,"analysis":33},875928,"某商场的两管制定风量空调系统，设置粗效和中效过滤器，风管平均比摩阻按0.8Pa\u002Fm估算，局部阻力按沿程阻力的50%估算，风机总效率为65%，组合空调器的阻力为400Pa，送风口和回风口的阻力为30Pa，根据相关节能标准，空调风系统的作用半径不应大于( )。",[185,187,189,191],{"key":20,"text":186,"correct":22},"80m",{"key":24,"text":188,"correct":22},"150m",{"key":28,"text":190,"correct":22},"260m",{"key":31,"text":192,"correct":26},"320m",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":28,"analysis":33},875929,"天津某大型超市建筑面积为2000㎡，用燃气红外辐射供暖，舒适温度为20℃，辐射管安装高度为5m，距人体头部3m，围护结构耗热量为200kW，辐射供暖系统的效率为0.9，室内空气温度为( )。",[197,199,201,203],{"key":20,"text":198,"correct":22},"20～21℃",{"key":24,"text":200,"correct":22},"18～19℃",{"key":28,"text":202,"correct":26},"16～17℃",{"key":31,"text":204,"correct":22},"22～23℃",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":28,"analysis":33},875930,"某防空地下室为二等人员掩蔽所(一个防护单元)，掩蔽人数N=415人，清洁新风量为5m3\u002F(P.h)，滤毒新风量为2m3\u002F(P.h)(滤毒风机风量为1000m3\u002Fh)，最小防毒通道有效容积为10m3，清洁区有效容积为1725m3，该掩蔽所设计的防毒通道的最小换气次数接近下列哪一项？",[209,211,213,215],{"key":20,"text":210,"correct":22},"200次\u002Fh",{"key":24,"text":212,"correct":22},"93次\u002Fh",{"key":28,"text":214,"correct":26},"76次\u002Fh",{"key":31,"text":216,"correct":22},"40次\u002Fh",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":28,"analysis":33},875931,"-空气调节系统的冷水管道，当供回水温度为7\u002F12℃，所采用水泵的设计工作点的效率为68%时，符合节能设计标准的水泵设计扬程，最接近的应是下列哪一项？",[221,223,225,227],{"key":20,"text":222,"correct":22},"29m",{"key":24,"text":224,"correct":22},"32m",{"key":28,"text":226,"correct":26},"35m",{"key":31,"text":228,"correct":22},"38m",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":24,"analysis":33},875932,"容量为700人的会议室，室内空气温度为20℃，室外空气温度为16℃。每人总发热量为110w，其中潜热量为30W，外围护结构损耗热量为7000W，所需通风量为下列哪一项？",[233,235,237,239],{"key":20,"text":234,"correct":22},"3～5kg\u002Fs",{"key":24,"text":236,"correct":26},"11.5～12.5kg\u002Fs",{"key":28,"text":238,"correct":22},"17～18kg\u002Fs",{"key":31,"text":240,"correct":22},"50～52kg\u002Fs",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":243,"answer":24,"analysis":33},875933,[244,245,246,247],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":26},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":22},{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":28,"analysis":33},875934,"某商业综合体内办公建筑面积135000㎡、商业建筑面积75000㎡、宾馆建筑面积50000㎡，其夏季空调冷负荷建筑面积指标分别为：90W／㎡、140W\u002F㎡、110W／㎡(已考虑各种因素的影响)，冷源为蒸汽溴化锂吸收式制冷机组，市政热网供应0.4MPa的蒸汽，市政热网的供热负荷是下列何项？( )。",[252,254,256,258],{"key":20,"text":253,"correct":22},"40220～46920kW",{"key":24,"text":255,"correct":22},"31280～37530kW",{"key":28,"text":257,"correct":26},"23460～28150kW",{"key":31,"text":259,"correct":22},"20110～21650kW",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":262,"answer":31,"analysis":33},875935,[263,265,267,269],{"key":20,"text":264,"correct":22},"8.0～8.9kW",{"key":24,"text":266,"correct":22},"9.0～9.9kW",{"key":28,"text":268,"correct":22},"10.0～10.9kW",{"key":31,"text":270,"correct":26},"11.0～12.0kW",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":273,"answer":31,"analysis":33},875936,[274,275,276,277],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":22},{"key":31,"text":33,"correct":26},{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":280,"answer":24,"analysis":33},875937,[281,283,285,287],{"key":20,"text":282,"correct":22},"31～33℃",{"key":24,"text":284,"correct":26},"28～30℃",{"key":28,"text":286,"correct":22},"34～36℃",{"key":31,"text":288,"correct":22},"＞36℃",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":28,"analysis":33},875938,"某工厂厂区采用蒸汽供暖，蒸汽压力为0.6MPa，从锅炉到最远用户的距离为500m，摩擦压力损失占总压力损失的60%，单位长度摩擦压力损失为( )。",[293,295,297,299],{"key":20,"text":294,"correct":22},"720Pa\u002Fm",{"key":24,"text":296,"correct":22},"300Pa\u002Fm",{"key":28,"text":298,"correct":26},"180Pa\u002Fm",{"key":31,"text":300,"correct":22},"100Pa\u002Fm",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":28,"analysis":33},875939,"某22层写字楼的消防电梯前室，有两个出入口并设有单扇门，其加压送风系统的最小送风量为( )。",[305,306,307,308],{"key":20,"text":33,"correct":22},{"key":24,"text":33,"correct":22},{"key":28,"text":33,"correct":26},{"key":31,"text":33,"correct":22},[310,313,316,319,322,325],{"id":15,"name":311,"category":7,"favorite":312},"领导干部任职前廉政法规知识测试题",92,{"id":314,"name":315,"category":7,"favorite":15},595,"建筑结构与设备",{"id":317,"name":318,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":320,"name":321,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":323,"name":324,"category":7,"favorite":8},534,"BIM工程师",{"id":326,"name":324,"category":7,"favorite":8},535]