[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-875614":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},875614,564,1,"单选题","某热水集中采暖系统的设计参数：采暖热负荷为750kW，供回水温度为95／70℃。系统计算阻力损失为30kPa。实际运行时于系统的热力人口处测得：供回水压差为34.7kPa，供回水温度为80／60℃，系统实际运行的热负荷，应为下列哪一项？",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","530～560kW",false,{"key":16,"text":17,"correct":14},"B","570～600kW",{"key":19,"text":20,"correct":14},"C","605～635kW",{"key":22,"text":23,"correct":24},"D","640～670kW",true,"",{"id":6,"name":27,"category":28,"favorite":29},"专业案例（暖通空调专业）","建筑工程",0]