[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-875332":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},875332,563,1,"单选题","",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","2处",false,{"key":16,"text":17,"correct":18},"B","3处",true,{"key":20,"text":21,"correct":14},"C","4处",{"key":23,"text":24,"correct":14},"D","5处","根据《建筑给水排水设计规范》4.6.2条，本例中必须设置通气立管；根据4.6.3～4.6.5条，主、副通气立管必须要与环形通气管一起设置。而图中无环形通气管，说明横支管上承担的卫生器具数量没有超过允许负荷，也就无法设置主、副通气立管。故本建筑的通气立管只能设置成专用通气立管。①正确。根据规范4.5.13条，铸铁排水管道设置的清扫口，其材质应为铜质。本例中第2层悬吊管连接的卫生器具肯定大于3个，需设置清扫口，但材质应为铜质，而不是和排水管同材质。故②错误。根据规范4.5.12条，本建筑层高3.6m，若每隔两层设置检查口，其间距为3.6×3=10.8m＞10m，不合适，故宜隔层设置。③正确。WL-3污水立管在第7层上方有乙字管，故在第8层应设置检查口。④正确。WL-2污水立管设有卫生器具的最高层为第10层，故最上部的检查口应设在第10层而不是第11层。⑤错误。",{"id":6,"name":27,"category":28,"favorite":29},"专业案例（给排水）","建筑工程",0]