[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-875196":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},875196,563,1,"单选题","某5层办公楼每层设有一公共卫生间，排水由1根DN110塑料立管(伸顶通气)、埋地塑料管排出，排出管长度(立管管底距地下室外墙)10m。排水设计秒流量为2.46L\u002Fs。一层卫生间排水横支管与立管连接点标高为-0.40m，室外地坪标高为-0.55m，最大冻土深度为0.90m。排出管穿出外墙后的最小埋设深度对应的标高(m)宜为下列何值？( )",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","-0.95",false,{"key":16,"text":17,"correct":14},"B","-1.15",{"key":19,"text":20,"correct":21},"C","-1.19",true,{"key":23,"text":24,"correct":14},"D","-1.45","土壤冰冻线标高为-0.9-0.55=-1.45m.冰冻线以上0.5m标高为-1.45+0.5=-0.95m。该建筑为5层，最低排水横支管距离立管管底最小距离为0.75m，故排出管起点标高为-0.4-0.75=-1.15m，DN110塑料管最小排水坡度为0.004，坡降为0.004×10=0.04m，故排出管穿外墙后的最小埋设深度对应的标高为-1.15-0.04=-1.19m，满足冻土线要求。DN110管径0.004坡度时排水能力为2.69L\u002Fs，大于题干的2.46L\u002Fs。",{"id":6,"name":27,"category":28,"favorite":29},"专业案例（给排水）","建筑工程",0]