[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-875188":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},875188,563,1,"单选题","某常规处理工艺水厂，拟采用絮凝平流沉淀池下叠清水池方案。考虑絮凝沉淀池总水头损失0.75m，其中絮凝池水头损失0.34m，假定沉淀池出水渠水面距沉淀池底3.50m，上、下池隔板厚0.35m，清水池干弦高0.20m。在连接管水头损失取最大估算值的条件下，滤池允许的最大水头损失值为多少(m)？( )",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","3.71",false,{"key":16,"text":17,"correct":14},"B","3.64",{"key":19,"text":20,"correct":14},"C","3.30",{"key":22,"text":23,"correct":24},"D","3.05",true,"根据“沉淀池→滤池→清水池”的顺序，沉淀池出水渠的水面为起端水面，最终要能到终端水面(清水池的水面)。起端水面与终端水面的高差为：3.5+0.35+0.2=4.05m此流程中间考虑“沉淀池→滤池”的连接管损失0.5m，再考虑“滤池→清水池”的连接管损失0.5m，则滤池自身的损失最多只允许：4.05-0.5-0.5=3.05m。",{"id":6,"name":27,"category":28,"favorite":29},"专业案例（给排水）","建筑工程",0]