[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-562-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":588},{"id":5,"name":6,"category":7,"favorite":8},562,"专业案例（动力专业）","建筑工程",0,2,50,308,[13,29,40,52,64,76,88,95,107,118,129,141,153,165,176,187,199,210,221,233,244,256,268,280,292,299,311,322,334,344,355,367,379,390,401,413,425,437,449,461,473,484,495,506,518,530,542,554,566,577],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":17},874802,1,"单选题","",[19,22,25,27],{"key":20,"text":17,"correct":21},"A",true,{"key":23,"text":17,"correct":24},"B",false,{"key":26,"text":17,"correct":24},"C",{"key":28,"text":17,"correct":24},"D",{"id":30,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":31,"answer":26,"analysis":17},874803,[32,34,36,38],{"key":20,"text":33,"correct":24},"25.26%",{"key":23,"text":35,"correct":24},"26.27%",{"key":26,"text":37,"correct":21},"21.29%",{"key":28,"text":39,"correct":24},"22.58%",{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":20,"analysis":17},874804,"一台制冷量为50kW的活塞式制冷机，单位质量制冷量为145.4kj\u002Fkg，单位理论功为50.5kj\u002Fkg，则压缩机理论功率为( )kW。",[44,46,48,50],{"key":20,"text":45,"correct":21},"17.372",{"key":23,"text":47,"correct":24},"17.562",{"key":26,"text":49,"correct":24},"18.052",{"key":28,"text":51,"correct":24},"18.226",{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":26,"analysis":17},874805,"压缩式制冷装置压气机吸入的空气P1=0.1MPa，t1=27℃，定熵压缩至P2=0.5MPa，则所消耗的压缩功为( )kj\u002Fkg。",[56,58,60,62],{"key":20,"text":57,"correct":24},"169.6",{"key":23,"text":59,"correct":24},"172.6",{"key":26,"text":61,"correct":21},"176.8",{"key":28,"text":63,"correct":24},"182.5",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":20,"analysis":17},874806,"某压缩机站内设有3台压缩机，各台压缩机的声压级分别为92dB (A)、90dB (A)、93dB (A)，则总声压级为( )dB (A)。",[68,70,72,74],{"key":20,"text":69,"correct":21},"96.56",{"key":23,"text":71,"correct":24},"92",{"key":26,"text":73,"correct":24},"93",{"key":28,"text":75,"correct":24},"90",{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":26,"analysis":17},874807,"已知一供暖房间的外墙传热系数K=1.68W\u002F(㎡.℃)，供暖室内计算温度th=19℃，供暖室外计算温度tw=-13℃，外墙面积A为20㎡，则该外墙的基本耗热量Q为( )。",[80,82,84,86],{"key":20,"text":81,"correct":24},"871W",{"key":23,"text":83,"correct":24},"983W",{"key":26,"text":85,"correct":21},"1075W",{"key":28,"text":87,"correct":24},"1176W",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":90,"answer":28,"analysis":17},874808,[91,92,93,94],{"key":20,"text":17,"correct":24},{"key":23,"text":17,"correct":24},{"key":26,"text":17,"correct":24},{"key":28,"text":17,"correct":21},{"id":96,"libraryId":5,"type":15,"typeLabel":16,"stem":97,"options":98,"answer":26,"analysis":17},874809,"一北方住宅建筑，外墙采用2砖墙，内抹灰(δ=20mm)。已知砖墙的导热系数λ=0.81W／(m·K)，内抹灰的导热系数λ=0.87W／(m·K)。则该外墙的传热系数为( )。",[99,101,103,105],{"key":20,"text":100,"correct":24},"0.62W\u002F(㎡.K)",{"key":23,"text":102,"correct":24},"0.89W\u002F(㎡.K)",{"key":26,"text":104,"correct":21},"1.27W／(㎡.K)",{"key":28,"text":106,"correct":24},"1.52W／(㎡.K)",{"id":108,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":109,"answer":26,"analysis":17},874810,[110,112,114,116],{"key":20,"text":111,"correct":24},"1.528%",{"key":23,"text":113,"correct":24},"1.637%",{"key":26,"text":115,"correct":21},"1.865%",{"key":28,"text":117,"correct":24},"1.902%",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":120,"answer":20,"analysis":17},874811,[121,123,125,127],{"key":20,"text":122,"correct":21},"7.64",{"key":23,"text":124,"correct":24},"6.81",{"key":26,"text":126,"correct":24},"7.28",{"key":28,"text":128,"correct":24},"8.62",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":23,"analysis":17},874812,"有一厂区供暖用蒸汽量为20t／h，生活用蒸汽量为10t\u002Fh，生产工艺用汽量30t\u002Fh，锅炉房自用汽量为5t\u002Fh，则锅炉房的设计容量应为( )。",[133,135,137,139],{"key":20,"text":134,"correct":24},"48～51t／h",{"key":23,"text":136,"correct":21},"51～61t\u002Fh",{"key":26,"text":138,"correct":24},"73～75t\u002Fh",{"key":28,"text":140,"correct":24},"81～88t\u002Fh",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":26,"analysis":17},874813,"某天然气大气式燃烧器的热负荷为41868kj\u002Fh，若火孔热强度取6.5W／m㎡，则燃烧器的火孔总面积约为( )m㎡。",[145,147,149,151],{"key":20,"text":146,"correct":24},"1826",{"key":23,"text":148,"correct":24},"1857",{"key":26,"text":150,"correct":21},"1938",{"key":28,"text":152,"correct":24},"1905",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":26,"analysis":17},874814,"液化石油气密度ρ=2.35kg\u002Fm3，相对密度S=1.82.均使用钢管，用公式法进行水力计算，则单位长度管道压力降为( )Pa／m(低压输送Q0=10ms／h，管道长度L=80m，管道内径d=5cm)。",[157,159,161,163],{"key":20,"text":158,"correct":24},"1.09",{"key":23,"text":160,"correct":24},"0.98",{"key":26,"text":162,"correct":21},"1.18",{"key":28,"text":164,"correct":24},"1.56",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":167,"answer":23,"analysis":17},874815,[168,170,172,174],{"key":20,"text":169,"correct":24},"5.8%，1.45%",{"key":23,"text":171,"correct":21},"6.7%，1.45%",{"key":26,"text":173,"correct":24},"5.8%，2.28%",{"key":28,"text":175,"correct":24},"6.7%，2.28%",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":178,"answer":26,"analysis":17},874816,[179,181,183,185],{"key":20,"text":180,"correct":24},"38.5",{"key":23,"text":182,"correct":24},"39.5",{"key":26,"text":184,"correct":21},"42.5",{"key":28,"text":186,"correct":24},"46.5",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":28,"analysis":17},874817,"某锅炉房采用热力除氧时，给水最大流量为21.9t\u002Fh，液面压力为20kPa，当地海拔高度为900m，则除氧水箱最低液面至水泵进口所需高度为( )m。",[191,193,195,197],{"key":20,"text":192,"correct":24},"5.38",{"key":23,"text":194,"correct":24},"4.65",{"key":26,"text":196,"correct":24},"5.28",{"key":28,"text":198,"correct":21},"4.69",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":201,"answer":26,"analysis":17},874818,[202,204,206,208],{"key":20,"text":203,"correct":24},"3655.4Pa／m，177m\u002Fs",{"key":23,"text":205,"correct":24},"3655.4Pa\u002Fm，832.8m\u002Fs",{"key":26,"text":207,"correct":21},"776.9Pa\u002Fm，37.6m\u002Fs",{"key":28,"text":209,"correct":24},"776.9Pa／m，832.8m\u002Fs",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":212,"answer":28,"analysis":17},874819,[213,215,217,219],{"key":20,"text":214,"correct":24},"99.86",{"key":23,"text":216,"correct":24},"105.65",{"key":26,"text":218,"correct":24},"120.8",{"key":28,"text":220,"correct":21},"119.93",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":23,"analysis":17},874820,"某供热小区建筑面积为35×104㎡，由分散供暖改为集中供暖。改造前锅炉平均热效率为ηG=50%，热网效率ηw=92%；改造后锅炉平均热效率ηG=85%，热网效率ηw=95%。供暖室外计算温度tw’=-19℃，供暖期日平均温度tp=-5.7℃，室内计算温度tn=18℃，供暖期天数为152d，建筑物综合面积热指标为qF=65W／㎡。设标准煤发热值为29309kj\u002Fkg，则改造后年节约标准煤量为( )t的平方。",[225,227,229,231],{"key":20,"text":226,"correct":24},"6528",{"key":23,"text":228,"correct":21},"6109",{"key":26,"text":230,"correct":24},"5842",{"key":28,"text":232,"correct":24},"4987",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":235,"answer":20,"analysis":17},874821,[236,238,240,242],{"key":20,"text":237,"correct":21},"5236t",{"key":23,"text":239,"correct":24},"6748t",{"key":26,"text":241,"correct":24},"6931t",{"key":28,"text":243,"correct":24},"12167t",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":20,"analysis":17},874822,"已知气体的质量流量为G=6.95kg\u002Fs，叶片功h(叶片)=45.85kj\u002Fkg，泄漏损失系数β漏=0.012，则级的P阻为( )kW。",[248,250,252,254],{"key":20,"text":249,"correct":21},"3.82",{"key":23,"text":251,"correct":24},"2.56",{"key":26,"text":253,"correct":24},"2.89",{"key":28,"text":255,"correct":24},"3.62",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":28,"analysis":17},874823,"北方某房间有一面西外墙和西外窗，经计算西外墙的基本耗热量为1000W，西外窗的基本耗热量为450W，房间高度为6.5m，通过外窗的冷风渗透耗热量为200W。则该房间的总热负荷为( )。",[260,262,264,266],{"key":20,"text":261,"correct":24},"1595W",{"key":23,"text":263,"correct":24},"1760W",{"key":26,"text":265,"correct":24},"1764W",{"key":28,"text":267,"correct":21},"1799W",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":28,"analysis":17},874824,"设氮的一次节流液化系统的操作温度为290K和71.9K，该系统的制冷系数ε=0.0462，若将液化器用作制冷机，则该系统的卡诺效率为( )。",[272,274,276,278],{"key":20,"text":273,"correct":24},"0.1398",{"key":23,"text":275,"correct":24},"0.1427",{"key":26,"text":277,"correct":24},"0.1256",{"key":28,"text":279,"correct":21},"0.1402",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":20,"analysis":17},874825,"某用户为了生产与使用平衡，需设置气体贮罐，以解决短期频繁的用量波动。供气压力等于贮气罐设计压力，其压力一般需技术经济比较确定。已知供气压力P1=0.8MPa，用户使用压力P2=0.5MPa，环境温度为29℃，贮气量为3m3，则贮罐水容积为( )m3。",[284,286,288,290],{"key":20,"text":285,"correct":21},"11.1",{"key":23,"text":287,"correct":24},"12.5",{"key":26,"text":289,"correct":24},"17.4",{"key":28,"text":291,"correct":24},"10.6",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":294,"answer":26,"analysis":17},874826,[295,296,297,298],{"key":20,"text":17,"correct":24},{"key":23,"text":17,"correct":24},{"key":26,"text":17,"correct":21},{"key":28,"text":17,"correct":24},{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":26,"analysis":17},874827,"有DN150的普通钢管长度为100m。输送供热介质的最高温度为120℃，管道安装温度为20℃，则管道工作时的热伸长量为( )mm。",[303,305,307,309],{"key":20,"text":304,"correct":24},"130",{"key":23,"text":306,"correct":24},"150",{"key":26,"text":308,"correct":21},"111.6",{"key":28,"text":310,"correct":24},"100",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":313,"answer":23,"analysis":17},874828,[314,316,318,320],{"key":20,"text":315,"correct":24},"ΔPBC=140380Pa，ΔPcD=3587Pa",{"key":23,"text":317,"correct":21},"ΔPBc=140380Pa，ΔPcD=9715Pa",{"key":26,"text":319,"correct":24},"ΔPBC=11928Pa，ΔPCD=3587Pa",{"key":28,"text":321,"correct":24},"ΔPBC=11928Pa，ΔPcD=9715Pa",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":28,"analysis":17},874829,"已知气体的质量流量为G=6.42kg\u002FS，泄漏损失系数β漏=0.012，轮阻损失系数β阻=0.03，叶片功h(叶片)=45.85kj\u002Fkg，则级的实际耗功P实为( )kW。",[326,328,330,332],{"key":20,"text":327,"correct":24},"309",{"key":23,"text":329,"correct":24},"325",{"key":26,"text":331,"correct":24},"338",{"key":28,"text":333,"correct":21},"307",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":336,"answer":23,"analysis":17},874830,[337,338,340,342],{"key":20,"text":310,"correct":24},{"key":23,"text":339,"correct":21},"105.4",{"key":26,"text":341,"correct":24},"112.6",{"key":28,"text":343,"correct":24},"137.6",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":346,"answer":28,"analysis":17},874831,[347,349,351,353],{"key":20,"text":348,"correct":24},"460，102，合适",{"key":23,"text":350,"correct":24},"380，105，合适",{"key":26,"text":352,"correct":24},"460，102，不合适",{"key":28,"text":354,"correct":21},"548，110，不合适",{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":26,"analysis":17},874832,"C50-8.83\u002F0.118型抽汽凝汽式机组的热化抽汽量为193387kgh，回水比焓为334.94kj\u002Fkg，供热抽汽比焓为2620.52kj\u002Fkg，则该机组的热化供热量为( )GJ\u002Fh。",[359,361,363,365],{"key":20,"text":360,"correct":24},"380",{"key":23,"text":362,"correct":24},"352",{"key":26,"text":364,"correct":21},"442",{"key":28,"text":366,"correct":24},"456",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":23,"analysis":17},874833,"已知C-72沉淀极有效断面积F=3.53㎡，根据《发生炉煤气站设计规范》规定，电气滤清器的实际流速V1不宜大于0.8m\u002Fs，当其中一台清理或检修时，煤气的实际流速V2不宜小于12m／s.则C-72电气滤清器的适宜流量为( )m3／h。",[371,373,375,377],{"key":20,"text":372,"correct":24},"10528",{"key":23,"text":374,"correct":21},"10166",{"key":26,"text":376,"correct":24},"12256",{"key":28,"text":378,"correct":24},"13109",{"id":380,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":381,"answer":20,"analysis":17},874834,[382,384,386,388],{"key":20,"text":383,"correct":21},"38.69kj\u002Fkg，84.4%",{"key":23,"text":385,"correct":24},"38.69kj\u002Fkg，89.8%",{"key":26,"text":387,"correct":24},"25.56kj\u002Fkg，89.8%",{"key":28,"text":389,"correct":24},"25.56kj\u002Fkg，84.4%",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":392,"answer":20,"analysis":17},874835,[393,395,397,399],{"key":20,"text":394,"correct":21},"6.01",{"key":23,"text":396,"correct":24},"6.05",{"key":26,"text":398,"correct":24},"6.28",{"key":28,"text":400,"correct":24},"6.78",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":20,"analysis":17},874836,"为了扩大原料煤种，炼焦用煤通常采用配煤工艺。某焦化厂采用肥煤22%、焦煤26%、瘦煤16%、气煤36%的比例配煤炼焦。这四种煤的灰分含量(空气干燥基，重量%)各为煤灰分A1=9.4%、焦煤灰分A2=7.9%、瘦煤灰分A3=10.6%、气煤灰分A4=11.4%，则配煤的灰分为( )。",[405,407,409,411],{"key":20,"text":406,"correct":21},"9.92%",{"key":23,"text":408,"correct":24},"8.65%",{"key":26,"text":410,"correct":24},"7.52%",{"key":28,"text":412,"correct":24},"6.86%",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":23,"analysis":17},874837,"已知某液化石油气供应基地供应居民20万户，居民生活用气量指标为15kg\u002F(m.户)，居民气化率为95%，商业用户用气量占居民生活用气量的20%，小型工业用户用气量占10%，液化石油气燃料汽车用气量占5%，居民和商业用户月用气高峰系数为1.2，小型工业用户和燃料汽车月高峰系数为1，则月平均日供气量为( )t\u002Ftd。",[417,419,421,423],{"key":20,"text":418,"correct":24},"120.6",{"key":23,"text":420,"correct":21},"151.05",{"key":26,"text":422,"correct":24},"160.2",{"key":28,"text":424,"correct":24},"162.8",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":26,"analysis":17},874838,"已知气体的质量流量为G=6.95kg\u002Fs，泄漏损失系数β漏=0.012，轮阻损失系数β咀=0.03，叶片功h叶片=45.85kj\u002Fkg，则级的实际耗功P实为( )。",[429,431,433,435],{"key":20,"text":430,"correct":24},"237kW",{"key":23,"text":432,"correct":24},"246kW",{"key":26,"text":434,"correct":21},"332kW",{"key":28,"text":436,"correct":24},"548kW",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":20,"analysis":17},874839,"某市的采暖室外计算温度为-20℃，室内温度要求18℃，当实际室外温度为-15℃时，其热负荷为设计值的( )。",[441,443,445,447],{"key":20,"text":442,"correct":21},"0.87",{"key":23,"text":444,"correct":24},"0.85",{"key":26,"text":446,"correct":24},"0.80",{"key":28,"text":448,"correct":24},"0.75",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":20,"analysis":17},874840,"锅炉引风机铬牌上的参数为转速n=960r\u002Fmin，风压P=1400Pa，流量Q=20000m3\u002Fh，效率n=66%，配用电机功率为22kW。若用此风机输送温度为20℃的清洁空气，则新条件下的风压为( )Pa。",[453,455,457,459],{"key":20,"text":454,"correct":21},"2255",{"key":23,"text":456,"correct":24},"2362",{"key":26,"text":458,"correct":24},"2578",{"key":28,"text":460,"correct":24},"2120",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":23,"analysis":17},874841,"已知某台活塞式空气压缩机的一级压缩比为ε=3，吸气温度为t1=20℃，在不考虑压缩机进气过程的温度升高的条件下，其多变指数n=1.59，则一级压缩终了时的排气温度为( )。",[465,467,469,471],{"key":20,"text":466,"correct":24},"156℃",{"key":23,"text":468,"correct":21},"167℃",{"key":26,"text":470,"correct":24},"25℃",{"key":28,"text":472,"correct":24},"20℃",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":28,"analysis":17},874842,"烟囱根郝吸力为290Pa，烟囱内废气流量为41.28m3／s，废气平均温度为220℃，大气最高温度为35℃，废气密度1.38kg\u002Fml，大气密度为1.28kg／m3，设烟囱上部出口内径D上为3.5m，根部内径D下为6.85m。则烟囱高度为( )m。已知：λ=0.036，Vc=1.77m\u002Fs，T=(220+273)K，To=273K，V1=4.3m\u002Fs，K=1。",[477,479,481,483],{"key":20,"text":478,"correct":24},"97",{"key":23,"text":480,"correct":24},"98",{"key":26,"text":482,"correct":24},"99",{"key":28,"text":310,"correct":21},{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":486,"answer":20,"analysis":17},874843,[487,489,491,493],{"key":20,"text":488,"correct":21},"25495",{"key":23,"text":490,"correct":24},"26221",{"key":26,"text":492,"correct":24},"25007",{"key":28,"text":494,"correct":24},"27056",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":497,"answer":23,"analysis":17},874844,[498,500,502,504],{"key":20,"text":499,"correct":24},"7.7℃",{"key":23,"text":501,"correct":21},"-7.7℃",{"key":26,"text":503,"correct":24},"6.6℃",{"key":28,"text":505,"correct":24},"-6.6℃",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":23,"analysis":17},874845,"压缩式制冷装置压气机吸入的空气Pi=0.lMPa，t1=27℃，定熵压缩至p2=0.5MPa，再经定压冷却后温度降为32℃。则该制冷循环的制冷量为( )。",[510,512,514,516],{"key":20,"text":511,"correct":24},"183.98kj\u002Fkg",{"key":23,"text":513,"correct":21},"108.6kj\u002Fkg",{"key":26,"text":515,"correct":24},"111.14kj\u002Fkg",{"key":28,"text":517,"correct":24},"175.88kj\u002Fkg",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":23,"analysis":17},874846,"设大气温度为30℃，冷库温度为-20℃，则逆卡诺循环的制冷系数为( )。",[522,524,526,528],{"key":20,"text":523,"correct":24},"9.11",{"key":23,"text":525,"correct":21},"5.06",{"key":26,"text":527,"correct":24},"7.32",{"key":28,"text":529,"correct":24},"6.58",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":26,"analysis":17},874847,"炼焦用煤通常采用配煤工艺来扩大原料煤种，某焦化厂采用肥煤22%，焦煤26%，瘦煤16%，气煤36%的比例配煤炼焦。配煤的各煤种挥发分含量(空气干燥基，重量%)依次为V1=28.5%，V2=23.8%，V3=12.6%，V4=40.6%，则配煤的挥发分按照可加性近似计算为( )。",[534,536,538,540],{"key":20,"text":535,"correct":24},"28.6%",{"key":23,"text":537,"correct":24},"27.9%",{"key":26,"text":539,"correct":21},"29.1%",{"key":28,"text":541,"correct":24},"29.8%",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":20,"analysis":17},874848,"喷嘴的速度系数φ=0.95，则喷嘴的能量损失系数为( )。",[546,548,550,552],{"key":20,"text":547,"correct":21},"0.0975",{"key":23,"text":549,"correct":24},"0.0567",{"key":26,"text":551,"correct":24},"0.0826",{"key":28,"text":553,"correct":24},"0.0628",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":23,"analysis":17},874849,"若炉水碱度基本保持为13mmol／L，软水碱度为1.5mmol／L，由于蒸汽带水，其碱度为0.01mmol\u002FL，凝结水回收率为40%，则该锅炉的排污率为( )。",[558,560,562,564],{"key":20,"text":559,"correct":24},"6.54%",{"key":23,"text":561,"correct":21},"7.39%",{"key":26,"text":563,"correct":24},"8.20%",{"key":28,"text":565,"correct":24},"7.67%",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":568,"answer":28,"analysis":17},874850,[569,571,573,575],{"key":20,"text":570,"correct":24},"239.5，23",{"key":23,"text":572,"correct":24},"287.6，24",{"key":26,"text":574,"correct":24},"287.6，23",{"key":28,"text":576,"correct":21},"239.5，24",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":579,"answer":23,"analysis":17},874851,[580,582,584,586],{"key":20,"text":581,"correct":24},"7.56t／h，4000Pa",{"key":23,"text":583,"correct":21},"7.62t／h，5806Pa",{"key":26,"text":585,"correct":24},"7.62t／h，4000Pa",{"key":28,"text":587,"correct":24},"7.56t\u002Fh，5806Pa",[589,592,595,598,601,604],{"id":15,"name":590,"category":7,"favorite":591},"领导干部任职前廉政法规知识测试题",92,{"id":593,"name":594,"category":7,"favorite":15},595,"建筑结构与设备",{"id":596,"name":597,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":599,"name":600,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":602,"name":603,"category":7,"favorite":8},534,"BIM工程师",{"id":605,"name":603,"category":7,"favorite":8},535]