[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-562-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":587},{"id":5,"name":6,"category":7,"favorite":8},562,"专业案例（动力专业）","建筑工程",0,1,50,308,[13,33,44,55,67,79,90,102,110,122,133,144,155,167,179,190,201,212,224,236,247,259,271,283,294,306,318,330,341,352,363,375,384,396,403,415,427,438,450,461,473,484,495,507,519,530,542,553,565,576],{"id":14,"libraryId":5,"type":9,"typeLabel":15,"stem":16,"options":17,"answer":23,"analysis":32},874752,"单选题","已知某一离心压缩机气体的质量流量G=3.95；轮阻损失系数β阻=0.04，泄漏损失系数β漏=0.012，叶片功N(叶片)=43.9kj／kg，则离心压缩机的实耗功为N实为( )kW。",[18,22,26,29],{"key":19,"text":20,"correct":21},"A","160.12",false,{"key":23,"text":24,"correct":25},"B","182.42",true,{"key":27,"text":28,"correct":21},"C","192.6",{"key":30,"text":31,"correct":21},"D","206.72","",{"id":34,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":35,"answer":19,"analysis":32},874753,[36,38,40,42],{"key":19,"text":37,"correct":25},"23.45",{"key":23,"text":39,"correct":21},"25.2",{"key":27,"text":41,"correct":21},"26.28",{"key":30,"text":43,"correct":21},"27.12",{"id":45,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":46,"answer":27,"analysis":32},874754,[47,49,51,53],{"key":19,"text":48,"correct":21},"1.03，625kJ",{"key":23,"text":50,"correct":21},"1.12，-625kJ",{"key":27,"text":52,"correct":25},"1.16，-625kJ",{"key":30,"text":54,"correct":21},"1.28，625kJ",{"id":56,"libraryId":5,"type":9,"typeLabel":15,"stem":57,"options":58,"answer":23,"analysis":32},874755,"某厂锅炉房安装了两台燃煤链条蒸汽锅炉，采用多管旋风除尘器，除尘效率85%，因附近居民反映有烟尘污染，环保部门进行了罚款，并要求采取增强除尘效果，达到排放的措施，厂方经研究决定再加一级烟气水浴除尘装置，除尘效率为85%，则除尘系统总除尘效率为( )。",[59,61,63,65],{"key":19,"text":60,"correct":21},"98.65%",{"key":23,"text":62,"correct":25},"97.75%",{"key":27,"text":64,"correct":21},"98.20%",{"key":30,"text":66,"correct":21},"92.58%",{"id":68,"libraryId":5,"type":9,"typeLabel":15,"stem":69,"options":70,"answer":27,"analysis":32},874756,"压缩式制冷装置压气机吸入的空气Pi=0.lMPa，t1=27℃，定熵压缩至p2=0.5MPa，再经定压冷却后温度降为32℃。压缩机的制冷系数为( )。",[71,73,75,77],{"key":19,"text":72,"correct":21},"1.432",{"key":23,"text":74,"correct":21},"1.522",{"key":27,"text":76,"correct":25},"1.718",{"key":30,"text":78,"correct":21},"1.824",{"id":80,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":81,"answer":19,"analysis":32},874757,[82,84,86,88],{"key":19,"text":83,"correct":25},"4.120",{"key":23,"text":85,"correct":21},"4.56",{"key":27,"text":87,"correct":21},"3.868",{"key":30,"text":89,"correct":21},"4.252",{"id":91,"libraryId":5,"type":9,"typeLabel":15,"stem":92,"options":93,"answer":23,"analysis":32},874758,"某一供氧系统，平均耗氧量为350m3／h(气态)。每天供气为12h，拟采用液氧罐贮存。供应商补液氧周期为7d\u002F次，则液氧贮存罐的有效容积至少为( )m3。",[94,96,98,100],{"key":19,"text":95,"correct":21},"38",{"key":23,"text":97,"correct":25},"43",{"key":27,"text":99,"correct":21},"45",{"key":30,"text":101,"correct":21},"52",{"id":103,"libraryId":5,"type":9,"typeLabel":15,"stem":104,"options":105,"answer":23,"analysis":32},874759,"某供热小区建筑面积30×104㎡，供暖室外计算温度t‘=-19℃，供暖期天数152天，供暖期日平均温度tp=-5.7℃，室内计算温度tn=18℃，建筑物综合面积热指标qF=65W／㎡。则年耗热量为( )GJ。",[106,107,108,109],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":25},{"key":27,"text":32,"correct":21},{"key":30,"text":32,"correct":21},{"id":111,"libraryId":5,"type":9,"typeLabel":15,"stem":112,"options":113,"answer":27,"analysis":32},874760,"设氮的一次节流液化系统的操作温度为290K和71.9K。假设氮气被等温可逆压缩到10.1MPa，其低压对应于液氮在71.9K的饱和蒸气压(0.05MPa)。如果将题中的液化器用作制冷机，则该系统的制冷系数为( )。",[114,116,118,120],{"key":19,"text":115,"correct":21},"0.0372",{"key":23,"text":117,"correct":21},"0.0392",{"key":27,"text":119,"correct":25},"0.0462",{"key":30,"text":121,"correct":21},"0.0483",{"id":123,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":124,"answer":30,"analysis":32},874761,[125,127,129,131],{"key":19,"text":126,"correct":21},"7.74%～35.31%",{"key":23,"text":128,"correct":21},"13.5%～88%",{"key":27,"text":130,"correct":21},"40%～73.5%",{"key":30,"text":132,"correct":25},"19%～71%",{"id":134,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":135,"answer":30,"analysis":32},874762,[136,138,140,142],{"key":19,"text":137,"correct":21},"129.051J\u002Fkg",{"key":23,"text":139,"correct":21},"12.9J\u002Fkg",{"key":27,"text":141,"correct":21},"1290.5J\u002Fkg",{"key":30,"text":143,"correct":25},"129051J\u002Fkg",{"id":145,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":146,"answer":30,"analysis":32},874763,[147,149,151,153],{"key":19,"text":148,"correct":21},"11820",{"key":23,"text":150,"correct":21},"15268",{"key":27,"text":152,"correct":21},"12259",{"key":30,"text":154,"correct":25},"11985",{"id":156,"libraryId":5,"type":9,"typeLabel":15,"stem":157,"options":158,"answer":30,"analysis":32},874764,"有一汽轮机工作于500℃及环境温度为30℃的条件下，若该热机从热源吸热10000kJ，则产生的净功为( )kJ。",[159,161,163,165],{"key":19,"text":160,"correct":21},"6258",{"key":23,"text":162,"correct":21},"5826",{"key":27,"text":164,"correct":21},"5800",{"key":30,"text":166,"correct":25},"6080",{"id":168,"libraryId":5,"type":9,"typeLabel":15,"stem":169,"options":170,"answer":23,"analysis":32},874765,"氟利昂(R22)制冷剂在下列三种工况下：A工况tk=40℃，t0=5℃；B工况tk=40℃，t0=0℃；C工况tK=35℃，t0=0℃。各工况的理论制冷系数应满足( )。",[171,173,175,177],{"key":19,"text":172,"correct":21},"A工况制冷系数＞B工况制冷系数＞C工况制冷系数",{"key":23,"text":174,"correct":25},"A工况制冷系数＜B工况制冷系数＜C工况制冷系数",{"key":27,"text":176,"correct":21},"B工况制冷系数＞A工况制冷系数＞C工况制冷系数",{"key":30,"text":178,"correct":21},"C工况制冷系数＞B工况制冷系数＞A工况制冷系数",{"id":180,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":181,"answer":30,"analysis":32},874766,[182,184,186,188],{"key":19,"text":183,"correct":21},"321.2",{"key":23,"text":185,"correct":21},"305.9",{"key":27,"text":187,"correct":21},"320",{"key":30,"text":189,"correct":25},"326.7",{"id":191,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":192,"answer":19,"analysis":32},874767,[193,195,197,199],{"key":19,"text":194,"correct":25},"0.51",{"key":23,"text":196,"correct":21},"0.61",{"key":27,"text":198,"correct":21},"0.41",{"key":30,"text":200,"correct":21},"0.31",{"id":202,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":203,"answer":19,"analysis":32},874768,[204,206,208,210],{"key":19,"text":205,"correct":25},"1506901",{"key":23,"text":207,"correct":21},"1508256",{"key":27,"text":209,"correct":21},"1628049",{"key":30,"text":211,"correct":21},"132582",{"id":213,"libraryId":5,"type":9,"typeLabel":15,"stem":214,"options":215,"answer":30,"analysis":32},874769,"根据《发生炉煤气站设计规范》规定，电气滤清器的实际流速(V1)不宜大于0.8m\u002Fs，当其中一台清理或检修时，煤气的实际流速(V2)不宜大于1.2m\u002Fs，已知C-72沉淀极有效断面积为F=3.53㎡，则C-72电气滤清器的最大流量为( )m3\u002Fh。",[216,218,220,222],{"key":19,"text":217,"correct":21},"10166",{"key":23,"text":219,"correct":21},"12000",{"key":27,"text":221,"correct":21},"13200",{"key":30,"text":223,"correct":25},"15250",{"id":225,"libraryId":5,"type":9,"typeLabel":15,"stem":226,"options":227,"answer":19,"analysis":32},874770,"在于馏煤气初冷工艺中，横管式间接冷却器煤气与冷却水逆流换热，将煤气由tg1=85℃冷却到tg2=35℃，冷却水的进口温度tw1=25℃，出口温度tw2=45℃，总传热系数K=185W\u002F(㎡.k)，煤气与水之间的总传热量为Q=7000kW。间接冷却器的总传热面积为( )㎡。",[228,230,232,234],{"key":19,"text":229,"correct":25},"1768",{"key":23,"text":231,"correct":21},"864",{"key":27,"text":233,"correct":21},"1251",{"key":30,"text":235,"correct":21},"1025",{"id":237,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":238,"answer":23,"analysis":32},874771,[239,241,243,245],{"key":19,"text":240,"correct":21},"0.368",{"key":23,"text":242,"correct":25},"0.492",{"key":27,"text":244,"correct":21},"0.406",{"key":30,"text":246,"correct":21},"0.503",{"id":248,"libraryId":5,"type":9,"typeLabel":15,"stem":249,"options":250,"answer":23,"analysis":32},874772,"汽轮机进口速度的利用系数为M0=0，其调节级的理想比焓降Δh0=41.56kj\u002Fkg，则调节喷嘴出口的气流理想速度为( )m\u002Fs。",[251,253,255,257],{"key":19,"text":252,"correct":21},"278.3",{"key":23,"text":254,"correct":25},"288.3",{"key":27,"text":256,"correct":21},"3883",{"key":30,"text":258,"correct":21},"28.73",{"id":260,"libraryId":5,"type":9,"typeLabel":15,"stem":261,"options":262,"answer":19,"analysis":32},874773,"某厂所用的燃料油收到基的低位发热量Q(ar，net)=45000kj／kg，则其燃烧时的理论空气量为( )m3\u002Fkg。",[263,265,267,269],{"key":19,"text":264,"correct":25},"11.14",{"key":23,"text":266,"correct":21},"10.6",{"key":27,"text":268,"correct":21},"9.89",{"key":30,"text":270,"correct":21},"12.56",{"id":272,"libraryId":5,"type":9,"typeLabel":15,"stem":273,"options":274,"answer":27,"analysis":32},874774,"某液化石油气灌瓶采用15kg气瓶供应居民10万户用户，居民用气量指标为15kg\u002F(人·月)，月用气高峰系数为1.2；每天1班工作，每班工作6h，则日灌瓶量是( )。",[275,277,279,281],{"key":19,"text":276,"correct":21},"2000瓶",{"key":23,"text":278,"correct":21},"3000瓶",{"key":27,"text":280,"correct":25},"4000瓶",{"key":30,"text":282,"correct":21},"5000瓶",{"id":284,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":285,"answer":30,"analysis":32},874775,[286,288,290,292],{"key":19,"text":287,"correct":21},"2.68",{"key":23,"text":289,"correct":21},"3.27",{"key":27,"text":291,"correct":21},"2.56",{"key":30,"text":293,"correct":25},"3.86",{"id":295,"libraryId":5,"type":9,"typeLabel":15,"stem":296,"options":297,"answer":23,"analysis":32},874776,"冬天用一热泵向室内供热，使室内温度保持20℃。已知房屋的散热损失是50000kj\u002Fh，室外环境温度-10℃。则带动该热泵所需的最小功率为( )。",[298,300,302,304],{"key":19,"text":299,"correct":21},"0.82kW",{"key":23,"text":301,"correct":25},"1.42kW",{"key":27,"text":303,"correct":21},"1.64kW",{"key":30,"text":305,"correct":21},"1.98kW",{"id":307,"libraryId":5,"type":9,"typeLabel":15,"stem":308,"options":309,"answer":30,"analysis":32},874777,"某离心空气压缩机，空气进口压力P1=101.3×103Pa，出口压力P2=155×103Pa，空气的气体常数R=287.64J／(kg.k)，则压缩质量1kg空气的等温功h(等温)为( )J\u002Fkg。",[310,312,314,316],{"key":19,"text":311,"correct":21},"25628",{"key":23,"text":313,"correct":21},"28869",{"key":27,"text":315,"correct":21},"32652",{"key":30,"text":317,"correct":25},"35847",{"id":319,"libraryId":5,"type":9,"typeLabel":15,"stem":320,"options":321,"answer":23,"analysis":32},874778,"制冷循环的总制冷量为50kW，循环工况为：冷凝温度tk=40℃，蒸发温度t0=5℃，膨胀阀前的液体过冷度tu=35℃，压缩机的吸气温度t1=10℃。采用氟利昂22进行制冷循环时，理论制冷系数为( )。",[322,324,326,328],{"key":19,"text":323,"correct":21},"4.69",{"key":23,"text":325,"correct":25},"5.89",{"key":27,"text":327,"correct":21},"6.21",{"key":30,"text":329,"correct":21},"5.59",{"id":331,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":332,"answer":27,"analysis":32},874779,[333,335,337,339],{"key":19,"text":334,"correct":21},"48.5",{"key":23,"text":336,"correct":21},"46.5",{"key":27,"text":338,"correct":25},"44.5",{"key":30,"text":340,"correct":21},"42.5",{"id":342,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":343,"answer":19,"analysis":32},874780,[344,346,348,350],{"key":19,"text":345,"correct":25},"3160",{"key":23,"text":347,"correct":21},"3580",{"key":27,"text":349,"correct":21},"3680",{"key":30,"text":351,"correct":21},"3715",{"id":353,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":354,"answer":27,"analysis":32},874781,[355,357,359,361],{"key":19,"text":356,"correct":21},"0.35",{"key":23,"text":358,"correct":21},"0.42",{"key":27,"text":360,"correct":25},"0.4901",{"key":30,"text":362,"correct":21},"0.5109",{"id":364,"libraryId":5,"type":9,"typeLabel":15,"stem":365,"options":366,"answer":27,"analysis":32},874782,"下列关于型号为SHL35-1.6\u002F350-P的锅炉所表示的意义的说法错误的是( )。",[367,369,371,373],{"key":19,"text":368,"correct":21},"表示双锅筒横置链条炉排",{"key":23,"text":370,"correct":21},"额定蒸发量为35t／h",{"key":27,"text":372,"correct":25},"额定蒸汽压力为0.6MPa(表压)",{"key":30,"text":374,"correct":21},"出口过热蒸汽温度为350℃",{"id":376,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":377,"answer":19,"analysis":32},874783,[378,380,382],{"key":19,"text":379,"correct":25},"2.17kN／㎡",{"key":23,"text":381,"correct":21},"5.22kN／㎡",{"key":27,"text":383,"correct":21},"9.80kN\u002F㎡",{"id":385,"libraryId":5,"type":9,"typeLabel":15,"stem":386,"options":387,"answer":19,"analysis":32},874784,"一台压缩机组的名义工况制冷量为1864kW，电功率为416kW，则此机组在名义工况下的制冷性能系数COP为( )。",[388,390,392,394],{"key":19,"text":389,"correct":25},"4.48",{"key":23,"text":391,"correct":21},"4.52",{"key":27,"text":393,"correct":21},"4.55",{"key":30,"text":395,"correct":21},"4.61",{"id":397,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":398,"answer":27,"analysis":32},874785,[399,400,401,402],{"key":19,"text":32,"correct":21},{"key":23,"text":32,"correct":21},{"key":27,"text":32,"correct":25},{"key":30,"text":32,"correct":21},{"id":404,"libraryId":5,"type":9,"typeLabel":15,"stem":405,"options":406,"answer":27,"analysis":32},874786,"已知某离心式压缩机第一级的实际耗功为N实=48.68kj\u002Fkg，级的进口速度V1=31m\u002Fs，级的出口速度为V2=69.8m\u002Fs，则级的出口功能增量为ΔN动=( )kj\u002Fkg。",[407,409,411,413],{"key":19,"text":408,"correct":21},"2.88",{"key":23,"text":410,"correct":21},"1.85",{"key":27,"text":412,"correct":25},"1.96",{"key":30,"text":414,"correct":21},"2.52",{"id":416,"libraryId":5,"type":9,"typeLabel":15,"stem":417,"options":418,"answer":19,"analysis":32},874787,"某燃气锅炉房要设计一个调压站。已知燃气最大流量为2500m3／h，最小流量为2000m3／h，调压站进口气绝对压力P1=0.25～0.5MPa，调压器出口绝对压力P2=0.15MPa，标态时燃气密度ρ0=0.7435kg\u002Fm3，燃气温度为t=20℃。调压器前有快速安全切断阀，燃气的相对分子量为16.654。则该调压站需选用公称直径为( )mm的全启式燃气安全阀。全启式燃气安全阀公称直径的可选值为：25，32，40，50，80，100(mm)，流量系数为0.6。",[419,421,423,425],{"key":19,"text":420,"correct":25},"25",{"key":23,"text":422,"correct":21},"32",{"key":27,"text":424,"correct":21},"40",{"key":30,"text":426,"correct":21},"50",{"id":428,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":429,"answer":19,"analysis":32},874788,[430,432,434,436],{"key":19,"text":431,"correct":25},"37190",{"key":23,"text":433,"correct":21},"38650",{"key":27,"text":435,"correct":21},"35220",{"key":30,"text":437,"correct":21},"31006",{"id":439,"libraryId":5,"type":9,"typeLabel":15,"stem":440,"options":441,"answer":30,"analysis":32},874789,"某房间采用地板辐射采暖，室内温度要求为20℃，房间热负荷为1200W，地板面积为30㎡。加热管覆盖层为：60mm豆石混凝土，20mm水泥砂浆找平层，其平均导热系数λ=1.2W\u002F(m.k)，初步确定加热管间距为200mm。若地板表面温度取29℃，则加热管内热水平均温度为( )。",[442,444,446,448],{"key":19,"text":443,"correct":21},"32.8℃",{"key":23,"text":445,"correct":21},"52.7℃",{"key":27,"text":447,"correct":21},"36.5℃",{"key":30,"text":449,"correct":25},"33.7℃",{"id":451,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":452,"answer":19,"analysis":32},874790,[453,455,457,459],{"key":19,"text":454,"correct":25},"5～6",{"key":23,"text":456,"correct":21},"4～5",{"key":27,"text":458,"correct":21},"3～4",{"key":30,"text":460,"correct":21},"2～3",{"id":462,"libraryId":5,"type":9,"typeLabel":15,"stem":463,"options":464,"answer":27,"analysis":32},874791,"压缩空气通过气轮机进行绝热膨胀并对外做功。已知气轮机进气参数为P1=400kPa，T1=400K，排气参数为p2=200kPa，T2=350K。设空气为定比热理想气体，则每流过1kg气体造成的熵产为( )。",[465,467,469,471],{"key":19,"text":466,"correct":21},"0.032kj／(kg.K)",{"key":23,"text":468,"correct":21},"0.048kj／(kg.K)",{"key":27,"text":470,"correct":25},"0.064kj／(kg.K)",{"key":30,"text":472,"correct":21},"0.084kj／(kg.K)",{"id":474,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":475,"answer":23,"analysis":32},874792,[476,478,480,482],{"key":19,"text":477,"correct":21},"54",{"key":23,"text":479,"correct":25},"56",{"key":27,"text":481,"correct":21},"58",{"key":30,"text":483,"correct":21},"60",{"id":485,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":486,"answer":19,"analysis":32},874793,[487,489,491,493],{"key":19,"text":488,"correct":25},"9.6",{"key":23,"text":490,"correct":21},"8.58",{"key":27,"text":492,"correct":21},"7.72",{"key":30,"text":494,"correct":21},"9.257",{"id":496,"libraryId":5,"type":9,"typeLabel":15,"stem":497,"options":498,"answer":27,"analysis":32},874794,"对于C50-8.83\u002F0.118型抽气凝汽式机组，分产供热的锅炉效率和管道效率分别为0.75和0.96，联产供热的锅炉效率和管道效率分别为0.90和0.98，热网效率为0.97，热化供热量为442GJ／h，则集中供热的全年节约标煤量为( )t标煤／a。",[499,501,503,505],{"key":19,"text":500,"correct":21},"10565",{"key":23,"text":502,"correct":21},"11229",{"key":27,"text":504,"correct":25},"12868",{"key":30,"text":506,"correct":21},"13096",{"id":508,"libraryId":5,"type":9,"typeLabel":15,"stem":509,"options":510,"answer":19,"analysis":32},874795,"一台制冷量为50kW的活塞式制冷机，工作在高温热源温度为32℃，低温热源温度为-18℃，制冷剂为R134a，采用回热循环，压缩机的吸气温度为0℃，则压缩机的单位理论功为( )。",[511,513,515,517],{"key":19,"text":512,"correct":25},"50.5kW",{"key":23,"text":514,"correct":21},"60.6kW",{"key":27,"text":516,"correct":21},"40.4kW",{"key":30,"text":518,"correct":21},"30.3kW",{"id":520,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":521,"answer":23,"analysis":32},874796,[522,524,526,528],{"key":19,"text":523,"correct":21},"1.33kW",{"key":23,"text":525,"correct":25},"2.77kW",{"key":27,"text":527,"correct":21},"3.47kW",{"key":30,"text":529,"correct":21},"7.53kW",{"id":531,"libraryId":5,"type":9,"typeLabel":15,"stem":532,"options":533,"answer":27,"analysis":32},874797,"有一汽轮机工作于500℃及环境温度30℃，则该热机可能达到的最高热效率是( )。如从热源吸热10000kJ，则能产生净功为( )。",[534,536,538,540],{"key":19,"text":535,"correct":21},"5280kJ",{"key":23,"text":537,"correct":21},"58.20kJ",{"key":27,"text":539,"correct":25},"6080kJ",{"key":30,"text":541,"correct":21},"6428kJ",{"id":543,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":544,"answer":30,"analysis":32},874798,[545,547,549,551],{"key":19,"text":546,"correct":21},"29860",{"key":23,"text":548,"correct":21},"30096",{"key":27,"text":550,"correct":21},"36520",{"key":30,"text":552,"correct":25},"38830",{"id":554,"libraryId":5,"type":9,"typeLabel":15,"stem":555,"options":556,"answer":23,"analysis":32},874799,"有一内径为700mm，长为120km的天然气管道。当天然气压力为3.04MPa，温度为278K时，天然气的压缩因子为0.94，则管道中的天然气在标准状态下的体积约为( )万m3。",[557,559,561,563],{"key":19,"text":558,"correct":21},"133.2",{"key":23,"text":560,"correct":25},"144.7",{"key":27,"text":562,"correct":21},"150.8",{"key":30,"text":564,"correct":21},"155.6",{"id":566,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":567,"answer":30,"analysis":32},874800,[568,570,572,574],{"key":19,"text":569,"correct":21},"1.16，-675kJ",{"key":23,"text":571,"correct":21},"1.18，675kJ",{"key":27,"text":573,"correct":21},"1.18，1250kJ",{"key":30,"text":575,"correct":25},"1.16，-1250kJ",{"id":577,"libraryId":5,"type":9,"typeLabel":15,"stem":32,"options":578,"answer":19,"analysis":32},874801,[579,581,583,585],{"key":19,"text":580,"correct":25},"1496Pa",{"key":23,"text":582,"correct":21},"2851Pa",{"key":27,"text":584,"correct":21},"3740Pa",{"key":30,"text":586,"correct":21},"7790Pa",[588,591,594,597,600,603],{"id":9,"name":589,"category":7,"favorite":590},"领导干部任职前廉政法规知识测试题",92,{"id":592,"name":593,"category":7,"favorite":9},595,"建筑结构与设备",{"id":595,"name":596,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":598,"name":599,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":601,"name":602,"category":7,"favorite":8},534,"BIM工程师",{"id":604,"name":602,"category":7,"favorite":8},535]