[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-874918":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},874918,562,1,"单选题","空气在0.101MPa和293K下进入一个除节流过程外可逆的克劳特系统，被等温压缩到2.02MPa和233K，然后有70%的主流气分流到可逆绝热膨胀机中，其余空气则通过各级换热器在膨胀阀中膨胀到0.101MPa。假设膨胀功用来辅助压缩时的单位质量液体产品所需的净功。若该可逆克劳特系统用作制冷机，则制冷量为( )。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","92kJ\u002Fkg压缩空气",false,{"key":16,"text":17,"correct":18},"B","95.7kJ\u002Fkg压缩空气",true,{"key":20,"text":21,"correct":14},"C","85.6kJ\u002Fkg压缩空气",{"key":23,"text":24,"correct":14},"D","62.8kJ\u002Fkg压缩空气","由空气的压焓图查得：h1(0.101MPa，293K)=295kj\u002Fkgh2(2.02MPa，293K)-291kj\u002Fkgh3(2.02MPa，233K)=228kj\u002Fkghf(0.10MPa，饱和液体)=-126kj\u002Fkgs1(0.101MPa，293K)=6.83kj\u002F(kg.K)S2(2.02MPa，293K)=5.95kj／(kg.K)S3(2.02MPa，223K)=5.71kj\u002F(kg.K)假设为等熵膨胀，se=S3，于是在0.101MPa和98K时，he=97kj\u002Fkg。液化率可通过公式求出，式中x=qme／qm=0.7，将热力参数值代入后求得液化率为：y=(295-291)／(295+126)+0.7×[(228-97)／(295+126)]=0.227单位质量压缩空气通过膨胀机的膨胀功为：We\u002Fqm=x(h3-he)=0.7×(228-97)kj\u002Fkg=91.7kj\u002Fkg压缩机需用的压缩功为：-W\u002Fqm=T1(s1-s2)-(h1-h2)=[293×(6.83-5.95)-(295-291)]kj\u002Fkg=253.8kj\u002Fkg由于膨胀功被用于压缩过程，故压缩单位质量空气所需的净功为：-Wnet\u002Fqm=-W\u002Fqm-We／qm=[T1(S1-S2)-(h1-h2)]-x(h3-he)=[293×(6.83-5.95)-(295-291)-0.7×(228-97)]=162.11kj\u002Fkg则液化单位质量气体所需的净功为：-Wnet\u002Fqmf=162.11\u002F0.227kJ\u002Fkg液空=714.1kJ／kg液空该系统单位制冷量可由公式求取Qo\u002Fqm=(h1-h2)+x(h3-he)=[(295-291)+0.7×(228-97)]kj\u002Fkg压缩空气=95.7kj\u002Fkg压缩空气",{"id":6,"name":27,"category":28,"favorite":29},"专业案例（动力专业）","建筑工程",0]