[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-559-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},559,"C证（专职安全员）","建筑工程",0,7,50,413,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},868744,3,"判断题","根据《建设工程安全生产管理条例》规定，施工单位应当向作业人员提供安全防护用具和安全防护服装，并书面告知危险岗位的操作规程和违章操作的危害。",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},868745,"根据《建设工程施工现场消防安全技术规范》规定，施工现场用气时，储装气体的罐瓶及其附件应合格、完好和有效；严禁使用减压器及其他附件缺损的氧气瓶。",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},868746,"根据《建设工程施工现场消防安全技术规范》规定，专用消防配电线路应自施工现场总配电箱的总断路器下端接入，且应保持不间断供电。",[38,39],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},868747,"根据《建筑法》规定，工程监理人员发现工程设计不符合建筑工程质量标准或者合同约定的质量要求的，应当报告设计单位要求改正。",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},868748,"根据《建筑法》规定，禁止承包单位将其承包的全部建筑工程转包给他人，禁止承包单位将其承包的全部建筑工程肢解以后以分包的名义分别转包给他人。",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":25,"analysis":27},868749,"根据《建筑法》规定，在建筑物的合理使用寿命外，因建筑工程质量不合格受到损害的，有权向责任者要求赔偿。",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":25,"analysis":27},868750,"根据《建筑机械使用安全技术规程》规定，当同一施工地点有两台以上塔式起重机并可能相互干涉时，应制定群塔作业方案。两台塔式起重机之间，处于高位塔式起重机的最低位置的部位（吊钩升至最高点或平衡重的最低部位）与低位塔式起重机中处于最高位置部位之间的垂直距离不应小于2.5m。",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":21,"analysis":27},868751,"根据《建筑机械使用安全技术规程》规定，起吊重物达到额定起重量的90％以上时，严禁下降起重臂，严禁同时进行两种及以上的操作动作。",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},868752,"根据《建筑基坑支护技术规程》规定，采用锚杆或支撑的支护结构，在未达到设计规定的拆除条件时，严禁拆除锚杆或支撑。",[74,75],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},868753,"根据《建筑起重机械备案登记办法》，建筑起重机械出租单位或者自购建筑起重机械使用单位在建筑起重机械首次出租或安装前，应当向本单位工商注册所在地县级以上地方人民政府建设主管部门办理备案。",[80,81],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},868754,"根据《建筑施工安全技术统一规范》规定，危险等级为Ⅰ级、Ⅱ级的分部分项工程、机械设备及设施安装拆卸的施工作业，无需单独进行安全技术交底。",[86,87],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":25,"analysis":27},868755,"根据《建筑施工高处作业安全技术规范》规定，采用立网防护时，严禁使用密目式安全平网代替立网使用。",[92,93],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":25,"analysis":27},868756,"根据《建筑施工模板安全技术规范》规定，在立柱底距地面300mm高处，沿纵横水平方向应按纵下横上的程序设扫地杆。",[98,99],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":25,"analysis":27},868757,"根据《建筑施工起重吊装安全技术规范》规定，起重机的变幅指示器、力矩限制器和限位开关等安全保护装置，必须齐全完整、灵活可靠，可以用限位装置代替操作机构。",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},868758,"根据《建筑施工塔式起重机安装、使用、拆卸安全技术规程》规定，塔式起重机的力矩限制器、重量限制器、变幅限位器、行走限位器、高度限位器等安全保护装置不得随意调整和拆除，严禁用限位装置代替操纵机构。",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":25,"analysis":27},868759,"根据《建筑施工高处作业安全技术规范》规定，高处作业不得使用座板式单人吊具,可以使用自制吊篮。",[116,117],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":21,"analysis":27},868760,"根据《建筑施工工具式脚手架安全技术规范》规定，物料平台不得与附着式升降脚手架各部位和各结构构件相连，其荷载应直接传递给建筑工程结构。",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":25,"analysis":27},868761,"根据《建筑施工门式钢管脚手架安全技术规范》规定，同一层的构配件和加固杆件必须按先上后下、先内后外的顺序进行拆除。",[128,129],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},868762,"根据《建筑施工特种作业人员管理规定》，建筑施工特种作业人员必须经建设主管部门考核合格，取得建筑施工特种作业人员操作资格证书，方可上岗从事相应作业。",[134,135],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":21,"analysis":27},868763,"根据《建筑施工特种作业人员管理规定》，在施工中发生危及人身安全的紧急情况时，建筑施工特种作业人员有权立即停止作业或者撤离危险区域，并向施工现场专职安全生产管理人员和项目负责人报告。",[140,141],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},868764,"根据《脚手架施工现场专项应急方案》，脚手架搭设前须编制脚手架、支架搭设专项施工方案，经审批后才能实施，超过一定高度的须经专家评审。",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":21,"analysis":27},868765,"根据《脚手架施工现场专项应急方案》，在恶劣天气下或者风力达到五级以上时可以停止作业。",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":21,"analysis":27},868766,"根据《起重吊装施工现场专项应急方案》，操作人员在进行高空作业时，必须正确使用安全带，安全带一般应高挂低用。",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},868767,"根据《上海市安全生产条例》规定，安全生产监管部门应当加强执法队伍的建设，依法开展行政执法工作。专项监管部门应当配置与其监督管理工作相适应的执法力量。",[164,165],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":25,"analysis":27},868768,"根据《上海市安全生产条例》规定，安全生产教育和培训的时间按照国家和本市有关规定执行，费用由从业人员承担。",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":21,"analysis":27},868769,"根据《上海市建设工程文明施工管理规定》，建设工程施工现场围档的设置高度不得低于2米。",[176,177],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":21,"analysis":27},868770,"根据《上海市建设工程文明施工管理规定》，要求本市重点区域内施工工地的文明施工，围档应当图案简洁、美观且与周边环境相协调，高度不得低于2.5米。",[182,183],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":25,"analysis":27},868771,"根据《上海市建设工程质量和安全管理条例》的规定，对于首次上岗的施工作业人员，施工单位或者劳务分包单位应当在其正式上岗前安排不少于60天的实习操作。",[188,189],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":21,"analysis":27},868772,"根据《上海市扬尘污染防治管理办法》，在进行产生大量泥浆的施工作业时，应当配备相应的泥浆池、泥浆沟，做到泥浆不外流，废浆应当采用密封式罐车外运。",[194,195],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},868773,"根据《上海市扬尘污染防治管理办法》，在中心城、新城、中心镇、旅游区（点）范围内运输易产生扬尘污染的物料的单位和个人，应当采用密闭化车辆运输。",[200,201],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":21,"analysis":27},868774,"根据《生产安全事故应急预案管理办法》规定，生产经营单位应急预案分为综合应急预案、专项应急预案和现场处置方案。",[206,207],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":21,"analysis":27},868775,"根据《生产安全事故应急预案管理办法》规定，现场处置方案是指生产经营单位根据不同生产安全事故类型，针对具体场所、装置或者设施所制定的应急处置措施。",[212,213],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},868776,"根据《施工现场临时用电安全技术规范》规定，电缆线路必须采用埋地敷设，严禁沿地面明设，并应避免机械损伤和介质腐蚀。",[218,219],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":21,"analysis":27},868777,"根据《施工现场临时用电安全技术规范》规定，对混凝土搅拌机、钢筋加工机械、木工机械、盾构机械等设备进行清理、检查、维修时，必须首先将其开关箱分闸断电，呈现可见电源断点，并关门上锁。",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":21,"analysis":27},868778,"根据《施工现场临时用电安全技术规范》规定，每台用电设备必须有各自专用的开关箱，严禁用同一个开关箱直接控制2台及2台以上用电设备（含插座）。",[230,231],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":21,"analysis":27},868779,"焊接操作及配合人员必须按规定穿戴劳动防护用品。",[236,237],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":21,"analysis":27},868780,"焊接铜、铝、锌、锡等有色金属时，应通风良好，焊接人员应戴防毒面罩、呼吸滤清器或采取其他防毒措施。",[242,243],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":25,"analysis":27},868781,"基坑开挖深度大于12m或基坑采用支护结构与主体相结合时，属一级安全等级基坑工程。",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":21,"analysis":27},868782,"基坑开挖应按照分层、分段、分块、对称、平衡、限时的方法确定开挖顺序。",[254,255],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":21,"analysis":27},868783,"建设单位不得明示或者暗示施工单位购买、租赁、使用不符合安全施工要求的安全防护用具、机械设备、施工机具及配件、消防设施和器材。",[260,261],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":25,"analysis":27},868784,"建筑高度大于24m或单体体积超过30000m3的在建工程，应设置临时室外消防给水系统。",[266,267],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},868785,"交流焊机实际上是一个交流变压器，是一种最简单常用的弧焊电焊机。",[272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":21,"analysis":27},868786,"脚手架必须设置纵、横向扫地杆。纵向扫地杆应采用直角扣件固定在距底座上皮不大于200mm处的立杆上。",[278,279],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":25,"analysis":27},868787,"开挖边坡土方，严禁切割坡脚，防止边坡失稳；当山坡坡度陡于1／3，或在软土地段，不得在挖方上侧堆土。",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":25,"analysis":27},868788,"开挖深度超过4.0m的基坑应采用分段开挖的方法；边长超过50m的基坑应采用分层开挖的方法。",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},868789,"可燃材料堆场及其加工场、易燃易爆危险品库房可以布置在架空电力线下。",[296,297],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},868790,"可燃材料及易燃易爆危险品应按计划限量进场。",[302,303],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":25,"analysis":27},868791,"扣件式脚手架必须设置纵、横向水平杆和立杆，三杆交汇处用旋转扣件相互连接、并应尽量紧靠，此三杆紧靠的扣接点称为扣件式脚手架的主节点。",[308,309],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":25,"analysis":27},868792,"跨度4m以上的梁下立柱拆除时，应按施工方案规定的顺序进行；若无明确规定时，应先从两端拆除，对称地向跨中进行。",[314,315],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":25,"analysis":27},868793,"立杆的对接扣件应交错布置，相邻两根立杆的接头应设置在同一步距内。",[320,321],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[323,327,330,333,336,339],{"id":324,"name":325,"category":7,"favorite":326},1,"领导干部任职前廉政法规知识测试题",92,{"id":328,"name":329,"category":7,"favorite":324},595,"建筑结构与设备",{"id":331,"name":332,"category":7,"favorite":324},715,"招标采购专业知识与法律法规",{"id":334,"name":335,"category":7,"favorite":324},848,"市政方向-通用基础",{"id":337,"name":338,"category":7,"favorite":8},534,"BIM工程师",{"id":340,"name":338,"category":7,"favorite":8},535]