[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-558-20":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":734},{"id":5,"name":6,"category":7,"favorite":8},558,"江苏省C2证（土建安全员）","建筑工程",0,20,50,1521,[13,38,53,68,83,97,111,126,141,156,171,185,199,214,228,242,257,272,286,300,314,329,343,357,371,385,400,414,429,442,456,470,481,495,509,524,539,553,567,582,596,610,624,638,652,666,680,694,708,722],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},867871,2,"多选题","纵向水平杆（大横杆）的接头可以搭接或对接。搭接时有以下具体要求（ ）。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","搭接长度不应小于1M",true,{"key":24,"text":25,"correct":22},"B","应等间距设置3个旋转扣件固定",{"key":27,"text":28,"correct":29},"C","端部扣件盖板边缘至搭接杆端的距离不应小于500MM",false,{"key":31,"text":32,"correct":22},"D","端部扣件盖板边缘至搭接杆端的距离不应小于100MM",{"key":34,"text":35,"correct":29},"E","搭接长度应为0.5M","ABD","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},867872,"吊篮悬挂机构前支架严禁支撑在（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":29},"顶板上",{"key":24,"text":45,"correct":22},"女儿墙上",{"key":27,"text":47,"correct":22},"女儿墙外",{"key":31,"text":49,"correct":22},"悬挑结构边缘",{"key":34,"text":51,"correct":29},"以上都对","BCD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},867873,"关于脚手架连墙件覆盖面积的规定，（ ）是正确的。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"落地、密目式安全网全封闭脚手架搭设高度＞40米,每根连墙件覆盖面积≤27㎡",{"key":24,"text":60,"correct":22},"落地、密目式安全网全封闭脚手架搭设高度≤40米,每根连墙件覆盖面积≤40㎡",{"key":27,"text":62,"correct":22},"悬挑、密目式安全网全封闭脚手架搭设高度>60米,每根连墙件覆盖面积≤20㎡",{"key":31,"text":64,"correct":22},"悬挑、密目式安全网全封闭脚手架搭设高度≤40米,每根连墙件覆盖面积≤40㎡",{"key":34,"text":66,"correct":29},"悬挑、密目式安全网全封闭脚手架搭设高度40～60米,每根连墙件覆盖面积≤40㎡","ABCD",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},867874,"关于附着式升降脚手架的防坠落装置，下列说法正确的有（ ）。",[72,74,76,78,80],{"key":20,"text":73,"correct":29},"防坠落装置一般采用机械式的全自动装置，也可使用手动装置",{"key":24,"text":75,"correct":22},"防坠落装置应具有防尘、防污染的措施，并应灵敏可靠和运转自如",{"key":27,"text":77,"correct":29},"防坠落装置与升降设备可一起固定在建筑结构上",{"key":31,"text":79,"correct":29},"钢吊杆式防坠落装置，钢吊杆规格应由计算确定，且不应小于Φ20MM",{"key":34,"text":81,"correct":22},"防坠落装置应设置在竖向主框架处并附着在建筑结构上，每一升降点不得少于一个防坠落装置，防坠落装置在使用和升降工况下都必须起作用","BE",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":67,"analysis":37},867875,"安全锁或具有相同作用的独立安全装置的功能应满足（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":22},"对离心触发式安全锁，悬吊平台运行速度达到安全锁锁绳速度时，即能自动锁住安全钢丝绳，使悬吊平台在200MM范围内停住。",{"key":24,"text":90,"correct":22},"对摆臂式防倾斜安全锁，悬吊平台工作时纵向倾斜角度不大于8°时，能自动锁住并停止运行。",{"key":27,"text":92,"correct":22},"安全锁或具有相同作用的独立安全装置，在锁绳状态下应不能自动复位。",{"key":31,"text":94,"correct":22},"安全锁必须在有效标定期限内使用，有效标定期限不大于1年。",{"key":34,"text":96,"correct":29},"安全锁必须在有效标定期限内使用，有效标定期限不大于2年。",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":67,"analysis":37},867876,"脚手架按照支承部位和形式可以分为（ ）。",[101,103,105,107,109],{"key":20,"text":102,"correct":22},"落地式",{"key":24,"text":104,"correct":22},"悬挑式",{"key":27,"text":106,"correct":22},"附墙悬挂脚手架",{"key":31,"text":108,"correct":22},"附着式升降脚手架",{"key":34,"text":110,"correct":29},"木脚手架",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":125,"analysis":37},867877,"施工单位应对（ ）编制专项施工方案并组织专家论证。",[115,117,119,121,123],{"key":20,"text":116,"correct":29},"搭设高度24M及以上落地式钢管脚手架工程",{"key":24,"text":118,"correct":22},"搭设高度50M及以上落地式钢管脚手架工程",{"key":27,"text":120,"correct":29},"提升高度100M及以上附着式整体和分片提升脚手架工程",{"key":31,"text":122,"correct":22},"提升高度150M及以上附着式整体和分片提升脚手架工程",{"key":34,"text":124,"correct":22},"搭设高度20M及以上悬挑式脚手架工程","BDE",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":140,"analysis":37},867878,"脚手架使用中,应定期检查的项目有（ ）。",[130,132,134,136,138],{"key":20,"text":131,"correct":22},"地基是否积水,底座是否松动,立杆是否悬空",{"key":24,"text":133,"correct":22},"扣件螺栓是否松动",{"key":27,"text":135,"correct":29},"立杆的沉降与垂直度的偏差是否符合规范规定",{"key":31,"text":137,"correct":29},"搭设高度",{"key":34,"text":139,"correct":22},"是否超载","ABE",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":155,"analysis":37},867879,"当采用钢管扣件作斜杆应符合哪些规定（ ）。",[145,147,149,151,153],{"key":20,"text":146,"correct":22},"斜杆应每步与立杆扣接，扣接点距碗扣节点的距离不应大于150MM",{"key":24,"text":148,"correct":22},"当出现不能与立杆扣接时，应与横杆扣接，扣件扭紧力矩应为40～65N·M",{"key":27,"text":150,"correct":22},"纵向斜杆应在全高方向设置成八字形且内对称",{"key":31,"text":152,"correct":29},"斜杆间距不应大于3跨",{"key":34,"text":154,"correct":22},"当模板支撑架高度大于4.8M时，顶端和底部必须设置水平剪刀撑，中间水平剪刀撑设置间距应小于或等于4.8M","ABCE",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":170,"analysis":37},867880,"附着式脚手架应在（ ）的阶段进行检查和验收。",[160,162,164,166,168],{"key":20,"text":161,"correct":22},"首次安装完毕。",{"key":24,"text":163,"correct":22},"提升或下降前。",{"key":27,"text":165,"correct":22},"提升、下降到位，投入使用前。",{"key":31,"text":167,"correct":29},"遇有七级大风与大雨后；",{"key":34,"text":169,"correct":29},"停用超过半个月","ABC",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":67,"analysis":37},867881,"脚手架及其地基基础应在（ ）的阶段进行检查和验收。",[175,177,179,181,183],{"key":20,"text":176,"correct":22},"基础完工后及脚手架搭设前",{"key":24,"text":178,"correct":22},"作业层上施加荷载前",{"key":27,"text":180,"correct":22},"每搭设完6～8M高度后",{"key":31,"text":182,"correct":22},"达到设计高度后",{"key":34,"text":184,"correct":29},"遇有七级及以上大风与大雨后",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":67,"analysis":37},867882,"施工单位对脚手架工程实行分包的要审查分包单位哪些内容（ ）。",[189,191,193,195,197],{"key":20,"text":190,"correct":22},"资质等级证书、营业执照、安全生产许可证。",{"key":24,"text":192,"correct":22},"审查主要管理人员的资格证书、专业分包项目负责人安全生产考核合格证书、专职安全生产管理人员安全生产考核合格证书。",{"key":27,"text":194,"correct":22},"审查架子工的上岗证书，并进行人证对照，做到人证相符。",{"key":31,"text":196,"correct":22},"审查安全生产管理机构的设置情况。",{"key":34,"text":198,"correct":29},"施工人员的身体状况",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":213,"analysis":37},867883,"关于脚手架搭设和使用中的荷载规定有（ ）。",[203,205,207,209,211],{"key":20,"text":204,"correct":22},"不得超载使用",{"key":24,"text":206,"correct":29},"结构用的脚手架作业层上的施工均布荷载标准值2.0KN\u002F㎡",{"key":27,"text":208,"correct":29},"装修用的脚手架作业层上的施工均布荷载标准值为3.0KN\u002F㎡",{"key":31,"text":210,"correct":22},"当在脚手架上同时有2个及以上操作层作业时，施工均布荷载标准值总和不得超过5.0KN\u002F㎡",{"key":34,"text":212,"correct":29},"当在脚手架上同时有3个及以上操作层作业时，施工均布荷载标准值总和不得超过5.0KN\u002F㎡","AD",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":170,"analysis":37},867884,"吊篮安全装置必须灵敏可靠,下列哪些属于安全装置（ ）。",[218,220,222,224,226],{"key":20,"text":219,"correct":22},"安全锁",{"key":24,"text":221,"correct":22},"安全绳",{"key":27,"text":223,"correct":22},"限位器",{"key":31,"text":225,"correct":29},"同步电机",{"key":34,"text":227,"correct":29},"异步电机",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":155,"analysis":37},867885,"下列有关吊篮使用和管理描述正确的是（ ）。",[232,234,236,238,240],{"key":20,"text":233,"correct":22},"操作吊篮的人员必须持特种作业证书上岗",{"key":24,"text":235,"correct":22},"吊篮内的作业人员不应超过2人",{"key":27,"text":237,"correct":22},"吊篮正常工作时，人员应从地面进人吊篮内",{"key":31,"text":239,"correct":29},"吊篮平台内应保持荷载均衡，可以适当超载运行",{"key":34,"text":241,"correct":22},"吊篮做升降运行时，工作平台两端高差不得超过150MM。",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":256,"analysis":37},867886,"门式脚手架杆件锁臂的搭设要求包括（ ）。",[246,248,250,252,254],{"key":20,"text":247,"correct":22},"脚手板、钢梯与门架相连的挂扣，应有防止脱落的扣紧机构。",{"key":24,"text":249,"correct":22},"门架应能配套使用，在不同组合情况下，均应保证连接方便、可靠，且应有良好的互换性。",{"key":27,"text":251,"correct":22},"门式脚手架或模板支架上下榀门架间应设置锁臂，当采用插销式或弹销式连接棒时，可不设锁臂。",{"key":31,"text":253,"correct":22},"搭设门架的锁臂、挂钩必须处于锁住状态。",{"key":34,"text":255,"correct":22},"门式脚手架应在门架两侧的立杆上设置纵向水平加固杆，并应采用扣件与门架立杆扣紧。","ABCDE",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":271,"analysis":37},867887,"附着式升降机脚手架必须具有（ ）的安全装置。",[261,263,265,267,269],{"key":20,"text":262,"correct":29},"防超载",{"key":24,"text":264,"correct":29},"防滑脱",{"key":27,"text":266,"correct":22},"防倾覆",{"key":31,"text":268,"correct":22},"防坠落",{"key":34,"text":270,"correct":22},"同步升降控制","CDE",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":170,"analysis":37},867888,"《建筑施工钢管扣件脚手架安全技术规范》规定，在脚手架使用期间，严禁拆除下列（ ）杆件。",[276,278,280,282,284],{"key":20,"text":277,"correct":22},"主节点处的纵、横向水平杆",{"key":24,"text":279,"correct":22},"主节点处的纵、横向扫地杆",{"key":27,"text":281,"correct":22},"连墙件",{"key":31,"text":283,"correct":29},"抛撑",{"key":34,"text":285,"correct":29},"支节点处的纵、横向水平杆",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":256,"analysis":37},867889,"建筑架子工的用人单位应当履行哪些职责（ ）",[290,292,294,296,298],{"key":20,"text":291,"correct":22},"与持有效执业资格证书的建筑架子工订立劳动合同。",{"key":24,"text":293,"correct":22},"书面告知建筑架子工违章操作的危害。",{"key":27,"text":295,"correct":22},"向建筑架子工提供齐全、合格的安全防护用品和安全的作业条件。",{"key":31,"text":297,"correct":22},"组织或者委托专业培训机构对本单位建筑架子工进行年度安全生产教育培训或者继续教育，培训时间不少于24小时。",{"key":34,"text":299,"correct":22},"制定并落实本单位特种作业安全操作规程和安全管理制度。",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":155,"analysis":37},867890,"下列关于在高处作业吊篮内进行电焊作业的陈述,正确的有（ ）。",[304,306,308,310,312],{"key":20,"text":305,"correct":22},"应对吊篮设备、钢丝绳、电缆采取保护措施",{"key":24,"text":307,"correct":22},"不得将电焊机放置在吊篮内",{"key":27,"text":309,"correct":22},"电焊缆线不得与吊篮任何部位接触",{"key":31,"text":311,"correct":29},"可利用吊篮作为电焊零线",{"key":34,"text":313,"correct":22},"电焊钳不得搭挂在吊篮上",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":328,"analysis":37},867891,"某玫瑰园小区住宅楼工地，外包队工人在拆除北侧外侧脚手架时，在未系安全带的情况下，进行拆除作业，不慎坠落，经送医院抢救无效死亡，针对此类事故，请结合所学知识，回答以下问题： 分析案例,本起事故产生的原因有（ ）。",[318,320,322,324,326],{"key":20,"text":319,"correct":29},"操作时不专心",{"key":24,"text":321,"correct":22},"作业人员安全意识淡薄",{"key":27,"text":323,"correct":22},"自我保护能力差",{"key":31,"text":325,"correct":29},"没有制定安全责任制",{"key":34,"text":327,"correct":22},"冒险违章作业","BCE",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":170,"analysis":37},867892,"施工现场需要考虑防直击雷的部位主要是（ ）等高大施工机械设备及钢脚手架、在建工程金属结构等高架设施。",[333,335,337,339,341],{"key":20,"text":334,"correct":22},"塔式起重机",{"key":24,"text":336,"correct":22},"外用电梯",{"key":27,"text":338,"correct":22},"物料提升机",{"key":31,"text":340,"correct":29},"混凝土搅拌机",{"key":34,"text":342,"correct":29},"泵送机械",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":155,"analysis":37},867893,"配电箱、开关箱的配电原则是（ ）。",[347,349,351,353,355],{"key":20,"text":348,"correct":22},"“三级配电、两级保护”原则",{"key":24,"text":350,"correct":22},"开关箱“一机、一闸、一漏、一箱”原则",{"key":27,"text":352,"correct":22},"动力、照明配电分设原则",{"key":31,"text":354,"correct":29},"“两级配电、两级保护”原则",{"key":34,"text":356,"correct":22},"分配电箱与开关箱的距离不得超过30M",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":140,"analysis":37},867894,"施工现场的用电系统，不论其供电方式如何，都属于（ ）的系统。",[361,363,365,367,369],{"key":20,"text":362,"correct":22},"电源中性点直接接地",{"key":24,"text":364,"correct":22},"220\u002F380V",{"key":27,"text":366,"correct":29},"工作零线与保护零线共用一线",{"key":31,"text":368,"correct":29},"三相四线制低压电力",{"key":34,"text":370,"correct":22},"三相五线制低压电力",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":256,"analysis":37},867895,"电气防火技术措施要点包括哪些（ ）。",[375,377,379,381,383],{"key":20,"text":376,"correct":22},"A.合理配置用电系统的短路、过载、漏电保护电器",{"key":24,"text":378,"correct":22},"确保P线连接点的电气连接可靠",{"key":27,"text":380,"correct":22},"在电气设备和线路周围不堆放并清除易燃易爆物和腐蚀介质，或作阻燃隔离防护",{"key":31,"text":382,"correct":22},"不在电气设备周围使用火源，特别在变压器、发电机等场所严禁烟火",{"key":34,"text":384,"correct":22},"在电气设备相对集中场所，如变电所、配电室、发电机室等场所，配备可扑灭电气火灾的灭火器材",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":399,"analysis":37},867896,"配电室的位置有哪些要求（ ）。",[389,391,393,395,397],{"key":20,"text":390,"correct":22},"靠近电源",{"key":24,"text":392,"correct":29},"远离负荷中心",{"key":27,"text":394,"correct":22},"进、出线方便",{"key":31,"text":396,"correct":22},"周边道路扬通",{"key":34,"text":398,"correct":22},"周围环境灰尘少、潮气少、振动少","ACDE",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":213,"analysis":37},867897,"配电箱、开关箱（ ）操作顺序正确。",[404,406,408,410,412],{"key":20,"text":405,"correct":22},"送电操作顺序为：总配电箱—分配电箱—开关箱",{"key":24,"text":407,"correct":29},"送电操作顺序为：开关箱—分配电箱—总配电箱",{"key":27,"text":409,"correct":29},"停电操作顺序为：总配电箱—分配电箱一开关箱",{"key":31,"text":411,"correct":22},"停电操作顺序为：开关箱—分配电箱一总配电箱",{"key":34,"text":413,"correct":29},"以上都可以",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":428,"analysis":37},867898,"Ⅱ类手持电动工具适用的场所为（ ）。",[418,420,422,424,426],{"key":20,"text":419,"correct":29},"管道",{"key":24,"text":421,"correct":29},"地沟内",{"key":27,"text":423,"correct":29},"锅炉内",{"key":31,"text":425,"correct":22},"金属构架上",{"key":34,"text":427,"correct":22},"潮湿场所","DE",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":271,"analysis":37},867899,"施工现场的用电设备基本上可分为（ ）等三大类。",[433,435,436,438,440],{"key":20,"text":434,"correct":29},"生活电器",{"key":24,"text":334,"correct":29},{"key":27,"text":437,"correct":22},"电动机械",{"key":31,"text":439,"correct":22},"电动工具",{"key":34,"text":441,"correct":22},"照明器",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":67,"analysis":37},867900,"施工现场外电防护的技术措施包括（ ）。",[446,448,450,452,454],{"key":20,"text":447,"correct":22},"绝缘",{"key":24,"text":449,"correct":22},"屏护",{"key":27,"text":451,"correct":22},"安全距离",{"key":31,"text":453,"correct":22},"采用24V及以下安全特低电压",{"key":34,"text":455,"correct":29},"采用漏电保护器",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":67,"analysis":37},867901,"三级配电系统的设置应遵循四项规则，即（ ）。",[460,462,464,466,468],{"key":20,"text":461,"correct":22},"分级分路规则",{"key":24,"text":463,"correct":22},"环境安全规则",{"key":27,"text":465,"correct":22},"动、照分设规则",{"key":31,"text":467,"correct":22},"压缩配电间距规则",{"key":34,"text":469,"correct":29},"用电安全规则",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":256,"analysis":37},867902,"起重机械主要有（ ）。",[474,475,477,479,480],{"key":20,"text":334,"correct":22},{"key":24,"text":476,"correct":22},"拌和设备",{"key":27,"text":478,"correct":22},"滑升模板",{"key":31,"text":336,"correct":22},{"key":34,"text":338,"correct":22},{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":52,"analysis":37},867903,"建筑施工现场临时用电工程专用的电源中性点直接接地的220V、380V三相四线制低压电力系统，必须符合下列规定（ ）。",[485,487,489,491,493],{"key":20,"text":486,"correct":29},"采用三相供电",{"key":24,"text":488,"correct":22},"采用三级配电系统",{"key":27,"text":490,"correct":22},"采用TN-S接零保护系统",{"key":31,"text":492,"correct":22},"采用二级漏电保护系统",{"key":34,"text":494,"correct":29},"采用IT配电系统",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":256,"analysis":37},867904,"施工现场临时用电必须建立安全技术档案,应包括的内容有（ ）。",[499,501,503,505,507],{"key":20,"text":500,"correct":22},"用电施工组织设计的全部资料",{"key":24,"text":502,"correct":22},"用电工程检查验收表",{"key":27,"text":504,"correct":22},"定期检（复）查表",{"key":31,"text":506,"correct":22},"接地电阻、绝缘电阻等参数测定记录表",{"key":34,"text":508,"correct":22},"电工安装、巡检、维修、拆除工作记录。",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":523,"analysis":37},867905,"下列选项中，直接引起坠落的客观危险元素有（ ）。",[513,515,517,519,521],{"key":20,"text":514,"correct":22},"阵风风力五级（风速8.0M\u002FS）以上",{"key":24,"text":516,"correct":29},"平均气温等于或低于10℃的作业环境",{"key":27,"text":518,"correct":29},"接触冷水温度等于或低于15℃的作业",{"key":31,"text":520,"correct":22},"可能会引起各种灾害事故的作业环境",{"key":34,"text":522,"correct":22},"存在有毒气体或空气中含氧量低于0.195的作业环境","ADE",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":538,"analysis":37},867906,"模板支撑体系搭设和拆卸时的悬空作业，应符合（ ）。",[528,530,532,534,536],{"key":20,"text":529,"correct":22},"模板支撑应按规定的程序进行",{"key":24,"text":531,"correct":22},"不得在连接件和支撑件上攀登上下",{"key":27,"text":533,"correct":29},"在上下同一垂直面上装拆模板，一定要有防护措施",{"key":31,"text":535,"correct":22},"在2M以上高处搭设与拆除模板时，应设置操作平台",{"key":34,"text":537,"correct":22},"在进行高处拆模作业时应配置登高用具或搭设支架","ABDE",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":155,"analysis":37},867907,"关于外用电梯防高处坠落措施哪些说法是正确的（ ）。",[543,545,547,549,551],{"key":20,"text":544,"correct":22},"施工外用电梯各种限位应灵敏可靠",{"key":24,"text":546,"correct":22},"电梯上下运行行程内应保证无障碍物",{"key":27,"text":548,"correct":22},"楼层门应有防止人员和物料坠落措施",{"key":31,"text":550,"correct":29},"电梯轿厢内乘人、载物时,尽量不要超载",{"key":34,"text":552,"correct":22},"载荷应均匀分布，防止偏重",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":67,"analysis":37},867908,"附着式升降脚手架和其他外挂式脚手架设置要求有（ ）。",[557,559,561,563,565],{"key":20,"text":558,"correct":22},"安全可靠的防倾覆装置",{"key":24,"text":560,"correct":22},"安全可靠的防坠落装置",{"key":27,"text":562,"correct":22},"每一作业层架体外侧应设置符合要求的防护栏杆",{"key":31,"text":564,"correct":22},"每一作业层架体外侧应设置符合要求的挡脚板",{"key":34,"text":566,"correct":29},"每两层作业层架体外侧应设置符合要求的挡脚板",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":581,"analysis":37},867909,"在划分高处作业等级时，要考虑（ ）。",[571,573,575,577,579],{"key":20,"text":572,"correct":22},"坠落的危险程度",{"key":24,"text":574,"correct":22},"高处作业的危险性质",{"key":27,"text":576,"correct":29},"作业时间",{"key":31,"text":578,"correct":29},"作业人员素质",{"key":34,"text":580,"correct":29},"作业地点","AB",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":67,"analysis":37},867910,"依据《消防法》的规定，同一建筑物由两个以上单位管理或者使用的，应当明确各方的消防安全责任，并确定责任人对共用的（ ）进行统一管理。",[586,588,590,592,594],{"key":20,"text":587,"correct":22},"疏散通道",{"key":24,"text":589,"correct":22},"安全出口",{"key":27,"text":591,"correct":22},"建筑消防设施",{"key":31,"text":593,"correct":22},"消防车通道",{"key":34,"text":595,"correct":29},"楼道",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":399,"analysis":37},867911,"电焊操作应注意：（ ）。",[600,602,604,606,608],{"key":20,"text":601,"correct":22},"电焊机应当有单独开关，装在防火、防雨的闸箱内",{"key":24,"text":603,"correct":29},"焊割部位应当与氧气瓶、乙炔瓶、乙炔发生器及各种易燃、可燃材料隔离，与明火之间不得小于5M",{"key":27,"text":605,"correct":22},"电焊机应当设专用接地线，直接放在焊件上，接地线不准接在建筑物、机械设备、各种管道、避雷引下线和金属架上借路使用",{"key":31,"text":607,"correct":22},"电焊机一、二次线应当用线鼻子压接牢固，同时应当加装防护罩，防止松动、短路放弧等，引燃可燃物",{"key":34,"text":609,"correct":22},"严格执行防火规定和操作规程，操作时采取相应的防火措施，与看火人员密切配合，防止火灾",{"id":611,"libraryId":5,"type":15,"typeLabel":16,"stem":612,"options":613,"answer":155,"analysis":37},867912,"油漆料库与调料间的防火要求有（ ）。",[614,616,618,620,622],{"key":20,"text":615,"correct":22},"油漆料库与调料间应分开设置，油漆料库和调料间应与散发火花的场所保持一定的防火间距",{"key":24,"text":617,"correct":22},"性质相抵触、灭火方法不同的品种，应分库存放",{"key":27,"text":619,"correct":22},"涂料和稀释剂的存放和管理，应符合《仓库防火安全管理规则》的要求",{"key":31,"text":621,"correct":29},"调料间应有良好的通风，并应采用防爆电器设备，室内禁止一切火源，调料间可以兼做更衣室和休息室",{"key":34,"text":623,"correct":22},"调料人员应穿不易产生静电的工作服，不带钉子的鞋",{"id":625,"libraryId":5,"type":15,"typeLabel":16,"stem":626,"options":627,"answer":538,"analysis":37},867913,"《建设工程施工现场消防安全技术规范》规定，施工现场用火，应符合下列哪些要求？（ ）",[628,630,632,634,636],{"key":20,"text":629,"correct":22},"焊接、切割、烘烤或加热等动火作业前，应对作业现场的可燃物进行清理",{"key":24,"text":631,"correct":22},"作业现场及其附近无法移走的可燃物，应采用不燃材料对其覆盖",{"key":27,"text":633,"correct":29},"施工现场可以采用明火取暖",{"key":31,"text":635,"correct":22},"裸露的可燃材料上严禁直接进行动火作业",{"key":34,"text":637,"correct":22},"具有火灾、爆炸危险的场所严禁明火",{"id":639,"libraryId":5,"type":15,"typeLabel":16,"stem":640,"options":641,"answer":52,"analysis":37},867914,"下列有关在建工程临时疏散通道的防火要求，正确的是（ ）。",[642,644,646,648,650],{"key":20,"text":643,"correct":29},"临时疏散通道应具备与疏散要求相匹配的耐火性能，其耐火极限不应低于1.0H",{"key":24,"text":645,"correct":22},"设置在地面上的临时疏散通道，其净宽度不应小于1.5M",{"key":27,"text":647,"correct":22},"利用在建工程施工完毕的水平结构、楼梯作临时疏散通道，其净宽度不应小于1.0M",{"key":31,"text":649,"correct":22},"用于疏散的爬梯及设置在脚手架上的临时疏散通道，其净宽度不应小于0.6M",{"key":34,"text":651,"correct":29},"临时疏散通道为坡道，其坡度大于20℃时，应修建楼梯或台阶踏步或设置防滑条",{"id":653,"libraryId":5,"type":15,"typeLabel":16,"stem":654,"options":655,"answer":67,"analysis":37},867915,"施工工地防火安全管理具体要求有（ ）。",[656,658,660,662,664],{"key":20,"text":657,"correct":22},"工地应当建立消防管理制度、动火作业审批制度和易燃易爆物品的管理办法；",{"key":24,"text":659,"correct":22},"工地应当按施工规模建立消防组织，配备义务消防人员，并应当经过专业培训和定期组织进行演习；",{"key":27,"text":661,"correct":22},"工地应当按照总平面图划分防火责任区，根据作业条件合理配备灭火器材。当工程施工高度超过30米时，应当配备有足够扬程的消防水源和必须保障畅通的疏散通道：",{"key":31,"text":663,"correct":22},"动火作业现场应当有消防设备和义务消防人员随时施救；",{"key":34,"text":665,"correct":29},"各种气瓶应当统一集中存放，库房应当通风良好，各种设施符合防爆要求",{"id":667,"libraryId":5,"type":15,"typeLabel":16,"stem":668,"options":669,"answer":155,"analysis":37},867916,"乙炔站的防火防爆要求有哪些？（ ）。",[670,672,674,676,678],{"key":20,"text":671,"correct":22},"乙炔站的建筑物应采用一、二级耐火等级，一般应为单层建筑，与有明火的操作场所应保持30～50M间距",{"key":24,"text":673,"correct":22},"乙炔站泄压面积与乙炔站容积的比值应采用0.05～0.22M2\u002FM3",{"key":27,"text":675,"correct":22},"乙炔房宜采用不发生火花的地面，金属平台应当铺设橡皮垫层",{"key":31,"text":677,"correct":29},"有乙炔爆炸危险的房间与无爆炸危险的更衣室、值班室可以直通",{"key":34,"text":679,"correct":22},"操作人员不穿着带铁钉的鞋及易产生静电的服装",{"id":681,"libraryId":5,"type":15,"typeLabel":16,"stem":682,"options":683,"answer":428,"analysis":37},867917,"《建设工程施工现场消防安全技术规范》规定：（ ）。",[684,686,688,690,692],{"key":20,"text":685,"correct":29},"施工现场有可燃物的一律不得进行焊接、切割、烘烤或加热动火作业",{"key":24,"text":687,"correct":29},"在裸露的可燃物上直接进行动火作业时应注意防火安全",{"key":27,"text":689,"correct":29},"在具有火灾、爆炸危险的场所动火时应有防火措施",{"key":31,"text":691,"correct":22},"严禁使用减压器及其他附件缺损的氧气瓶",{"key":34,"text":693,"correct":22},"严禁使用乙炔专用减压器、回火防止器及其他附件缺损的乙炔瓶",{"id":695,"libraryId":5,"type":15,"typeLabel":16,"stem":696,"options":697,"answer":328,"analysis":37},867918,"木工操作间的防火要求有（ ）。",[698,700,702,704,706],{"key":20,"text":699,"correct":29},"操作间建筑应当采用耐燃材料搭建",{"key":24,"text":701,"correct":22},"抛光、电锯等部位的电气设备应当采用密封式或者防爆式。刨花、锯木较多部位的电动机，应当安装防尘罩",{"key":27,"text":703,"correct":22},"操作间内严禁吸烟和用明火作业",{"key":31,"text":705,"correct":29},"严格遵守操作规程，对旧木料可直接上锯",{"key":34,"text":707,"correct":22},"工作完毕应当拉闸断电，并经检查确认无火险后方可离开",{"id":709,"libraryId":5,"type":15,"typeLabel":16,"stem":710,"options":711,"answer":52,"analysis":37},867919,"电焊、气割作业防火管理基本要求叙述正常的（ ）。",[712,714,716,718,720],{"key":20,"text":713,"correct":29},"严格执行动火审批程序和制度。操作前应当办理动火申请手续，经项目负责人及消防或者安全技术部门审查批准后方可进行作业",{"key":24,"text":715,"correct":22},"进行电焊、气割前，应当由施工员或者班组长向操作、看火人员进行消防安全技术措施交底，任何领导不能以任何借口让电焊、气割工人进行冒险操作",{"key":27,"text":717,"correct":22},"电焊的导线不能与装有气体的气瓶接触，也不能与气焊的软管或者气体的导管放在一起。",{"key":31,"text":719,"correct":22},"焊割结束或者离开操作现场时，应当切断电源、气源",{"key":34,"text":721,"correct":29},"为了加快工作进度，焊割可与油漆、喷漆、脱漆、木工等易燃操作同时间、同部位上下交叉作业",{"id":723,"libraryId":5,"type":15,"typeLabel":16,"stem":724,"options":725,"answer":256,"analysis":37},867920,"单位应当履行下列消防安全职责，保障（ ）畅通，保证（ ）符合消防技术标准。",[726,727,729,731,733],{"key":20,"text":589,"correct":22},{"key":24,"text":728,"correct":22},"消防车通道畅通",{"key":27,"text":730,"correct":22},"保证防火防烟分区",{"key":31,"text":732,"correct":22},"防火间距",{"key":34,"text":587,"correct":22},[735,739,742,745,748,751],{"id":736,"name":737,"category":7,"favorite":738},1,"领导干部任职前廉政法规知识测试题",92,{"id":740,"name":741,"category":7,"favorite":736},595,"建筑结构与设备",{"id":743,"name":744,"category":7,"favorite":736},715,"招标采购专业知识与法律法规",{"id":746,"name":747,"category":7,"favorite":736},848,"市政方向-通用基础",{"id":749,"name":750,"category":7,"favorite":8},534,"BIM工程师",{"id":752,"name":750,"category":7,"favorite":8},535]