[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-867481":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":16,"analysis":25},867481,558,1,"单选题","门式脚手架上下榀门架立杆应在同一轴线位置上，轴线偏差不应大于（ ）mm。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","1",false,{"key":16,"text":17,"correct":18},"B","2",true,{"key":20,"text":21,"correct":14},"C","3",{"key":23,"text":24,"correct":14},"D","4","剪刀撑的构造应符合下列规定：1）剪刀撑斜杆与地面的倾角宜为45°。2）剪刀撑应采用旋转扣件与门架立杆扣紧。3）剪刀撑斜杆应采用搭接接长，搭接长度不宜小于1000mm，搭接处应采用3个及以上旋转扣件扣紧。4）每道剪刀撑的宽度不应大于6个跨距，且不应大于10m；也不应小于4个跨距，且不应小于6m。设置连续剪刀撑的斜杆水平间距宜为6～8m。（6）上下福门架立杆应在同一轴线位置上，门架立杆轴线的对接偏差不应大于2mm。（7）门架的两侧应设置交叉支撑，并与门架立杆上的锁销锁牢。（8）当交叉支撑、锁臂、连接棒等配件与门架相连时，应有防止退出的止退机构；当连接棒与锁臂一起应用时，连接棒可不受此限。脚手板、钢梯与门架相连的挂扣应有防止脱落帅扣紧机构。",{"id":6,"name":27,"category":28,"favorite":29},"江苏省C2证（土建安全员）","建筑工程",0]