[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-867449":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},867449,558,1,"单选题","连墙件设置位置要求有（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","偏离主节点的距离不应大于300MM",true,{"key":16,"text":17,"correct":18},"B","偏离主节点的距离不应大于600MM",false,{"key":20,"text":21,"correct":18},"C","宜靠近主节点设置",{"key":23,"text":24,"correct":18},"D","应从脚手架底层第一步纵向水平杆处开始设置","连墙件、剪刀撑、加固杆件、立杆偏差对架体整体刚度有着重要影响；连墙件的设置应按规范要求间距从底层第一步架开始，随脚手架搭设同步进行，不得漏设；剪刀撑、加固杆件位置应准确，角度应合理，连接应可靠，并连续设置形成闭合圈，以提高架体的纵向刚度。（1）连墙件的设置应符合下列规定：1）应靠近主节点设置，偏离主节点的距离不应大于300mm。2）应从底层第一步纵向水平杆处开始设置。当该处设置有困难时，应采用其他可靠措施固定。",{"id":6,"name":27,"category":28,"favorite":29},"江苏省C2证（土建安全员）","建筑工程",0]