[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-867441":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},867441,558,1,"单选题","根据规程JGJ231-2010,对双排脚手架的每步水平杆层,当无挂扣钢脚手架板加强水平层刚度时,应每几跨设置水平斜杆（ ）",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","3",false,{"key":16,"text":17,"correct":14},"B","4",{"key":19,"text":20,"correct":21},"C","5",true,{"key":23,"text":24,"correct":14},"D","6","构造应符合下列要求：1）当用承插型盘扣式钢管支架搭设双排脚手架时，搭设高度不宜大于24m。可根据使用要求选择架体几何尺寸，相邻水平杆步距宜选用2m，立杆纵距宜选用1.5m或1.8m，且不宜大于2.1m，立杆横距宜选用0.9m或1.2m。2）脚手架首层立杆宜采用不同长度的立杆交错布置，错开立杆竖向距离不应小于500mm。当需设置人行通道时，应符合《建筑施工承插型盘扣件钢管支架安全技术规程》（JGJ231）的规定，立杆底部应配置可调底座。3）双排脚手架的斜杆或剪刀撑设置应符合下列要求：沿架体外侧纵向每5跨每层应设置一根竖向斜杆或每5跨间应设置扣件钢管剪刀撑，端跨的横向每层应设置竖向斜杆。4）承插盘扣式钢管支架应由塔式单元扩大组合而成，拐角为直角的部位应设置立杆间的竖向斜杆。当作为外脚手架使用时，单跨立杆间可不设置斜杆。5）当设置双排脚手架人行通道时，应在通道上部架设支撑横梁，横梁截面大小应按跨度以及承受的荷载计算确定，通道两侧脚手架应加设斜杆；洞口顶部应铺设封闭的防护板，两侧应设置安全网；通行机动车的洞口，必须设置安全警示和防撞设施。6）对双排脚手架的每步水平杆层，当无挂扣钢脚手架板加强水平层刚度时，应每5跨设置水平斜杆",{"id":6,"name":27,"category":28,"favorite":29},"江苏省C2证（土建安全员）","建筑工程",0]