[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-849766":3},{"question":4,"library":23},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":22},849766,466,1,"单选题","如果溴化锂吸收式机组内充入氮气保养,在机组启动前的抽气方法是:首先将机组内的氮气的压力降至大气压力,关闭机组所有通向大气的阀门,然后启动真空泵,启动真空泵要求()主抽气阀。",[11,15,18],{"key":12,"text":13,"correct":14},"A","不打开",false,{"key":16,"text":17,"correct":14},"B","快速打开",{"key":19,"text":20,"correct":21},"C","缓慢打开",true,"首次开机抽气均使用真空抽气。先关闭机组所有通大气阀门，打开冷凝器抽气阀、吸收器抽气阀(开度较小)及真空泵上抽气阀，然后启动真空泵，再慢慢打开真空泵下抽气阀进行抽气。此时再慢慢打开吸收器抽气阀。真空泵下抽气阀和吸收器抽气阀的开度需由小到大，否则抽气速率太大，会使真空泵喷油或使真空泵发生故障。",{"id":6,"name":24,"category":25,"favorite":26},"制冷与空调设备运行操作","特种作业",0]