[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-849634":3},{"question":4,"library":23},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":22},849634,466,1,"单选题","分体式空调在制冷和送风模式下风速可以根据需要正常调整,而当转到制热模式时,风速始终很低,其原因可能是()。",[11,15,19],{"key":12,"text":13,"correct":14},"A","室内管温传感器损坏",true,{"key":16,"text":17,"correct":18},"B","室温传感器损坏",false,{"key":20,"text":21,"correct":18},"C","室外化霜温度传感器损坏损坏","● 故障现象:空调制热效果差，风速始终很低。● 原因分析:开机制热，风速很低,出风口很热，转换空调模式，在制冷和送风模式下风速可高、低调整，高、低风速明显，证明风扇电机正常，怀疑室内管温传感器特性改变。解决措施:更换室内管温传感器后试机一切正常。经验总经:空调制热时，由于有防冷风功能，室内温传感器室内换热器达到25摄氏度以上时内风机以微风工作，温度达到38摄氏度以上时以设定风速工作。以上故障首先观察发现风速低，且出风温度高，故检查风机是否正常，当判定风速正常后，分析可能传感器检查温度不正确，造成室内风机不能以设定风速运转，故更换传感器。",{"id":6,"name":24,"category":25,"favorite":26},"制冷与空调设备运行操作","特种作业",0]