[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-464-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":515},{"id":5,"name":6,"category":7,"favorite":8},464,"煤气作业","特种作业",0,5,50,1632,[13,31,41,51,61,71,81,91,101,111,121,131,141,151,161,171,180,189,199,209,216,226,236,246,256,265,275,285,295,303,311,321,331,341,354,364,374,384,394,404,416,426,433,443,455,465,475,485,495,505],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":30},847091,1,"单选题","煤气作业区域报警器发生报警时,现场作业人员应立即通知(),到现场防护处理。",[19,23,27],{"key":20,"text":21,"correct":22},"A","值班主任",false,{"key":24,"text":25,"correct":26},"B","煤气防护员",true,{"key":28,"text":29,"correct":22},"C","消防队","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},847092,"用户检修,堵完盲板后置换煤气用()放散管。",[35,37,39],{"key":20,"text":36,"correct":26},"吹刷",{"key":24,"text":38,"correct":22},"事故",{"key":28,"text":40,"correct":22},"过剩",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":28,"analysis":30},847093,"根据CO气体的毒性及工业现场的实际情况,应至少设定()报警",[45,47,49],{"key":20,"text":46,"correct":22},"一级",{"key":24,"text":48,"correct":22},"三级",{"key":28,"text":50,"correct":26},"二级",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":20,"analysis":30},847094,"焦炉煤气中的CO含量在(),相对浓度较低但也会造成中毒事故。",[55,57,59],{"key":20,"text":56,"correct":26},"6-8%",{"key":24,"text":58,"correct":22},"24-28%",{"key":28,"text":60,"correct":22},"50-60%",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},847095,"厂区办公室、生活室宜设置在厂区()风向的下风侧,离高炉100m以外的地点。",[65,67,69],{"key":20,"text":66,"correct":26},"常年最小频率",{"key":24,"text":68,"correct":22},"夏季最小频率",{"key":28,"text":70,"correct":22},"夏季最大频率",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":24,"analysis":30},847096,"打开煤气加压机、脱硫、净化等煤气系统的设备和管道时,应采取防止硫化物等()的措施",[75,77,79],{"key":20,"text":76,"correct":22},"附着",{"key":24,"text":78,"correct":26},"自燃",{"key":28,"text":80,"correct":22},"氧化",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":30},847097,"煤气加压站或混合站下列哪个地方必须设置强制通风设施。()",[85,87,89],{"key":20,"text":86,"correct":22},"二次仪表室",{"key":24,"text":88,"correct":26},"一次仪表室",{"key":28,"text":90,"correct":22},"加压混合管理室",{"id":92,"libraryId":5,"type":15,"typeLabel":16,"stem":93,"options":94,"answer":28,"analysis":30},847098,"进入煤气设备内部工作时,所用照明电压不得超过()V。",[95,97,99],{"key":20,"text":96,"correct":22},"36",{"key":24,"text":98,"correct":22},"24",{"key":28,"text":100,"correct":26},"12",{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":28,"analysis":30},847099,"炉子点火时,炉内燃烧系统具有一定的负压,点火程序必须()。",[105,107,109],{"key":20,"text":106,"correct":22},"什么顺序都可以",{"key":24,"text":108,"correct":22},"先开煤气、后点火",{"key":28,"text":110,"correct":26},"先点火、后开煤气",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":28,"analysis":30},847100,"混合煤气系统配置的热值仪检测的混合煤气热值一般比混合煤气的实际热值()。",[115,117,119],{"key":20,"text":116,"correct":22},"不能确定",{"key":24,"text":118,"correct":22},"超前",{"key":28,"text":120,"correct":26},"滞后",{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":20,"analysis":30},847101,"转炉煤气柜在进行转炉煤气回收时含氧量必须小于()。",[125,127,129],{"key":20,"text":126,"correct":26},"2%",{"key":24,"text":128,"correct":22},"1%",{"key":28,"text":130,"correct":22},"3%",{"id":132,"libraryId":5,"type":15,"typeLabel":16,"stem":133,"options":134,"answer":20,"analysis":30},847102,"依据《职业病防治法》的规定,对遭受或者可能遭受急性职业病危害的劳动者,用人单位应当及时组织救治、进行健康检查和医学观察,所需费用由()承担。",[135,137,139],{"key":20,"text":136,"correct":26},"用人单位",{"key":24,"text":138,"correct":22},"劳动者个人",{"key":28,"text":140,"correct":22},"劳动者个人和用人单位共同",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":28,"analysis":30},847103,"带煤气进行检修作业不存在以下哪些风险()",[145,147,149],{"key":20,"text":146,"correct":22},"爆炸",{"key":24,"text":148,"correct":22},"着火",{"key":28,"text":150,"correct":26},"淹溺",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":24,"analysis":30},847104,"为保证仪器的检测报警精度,检测量程不宜大于报警值的()倍",[155,157,159],{"key":20,"text":156,"correct":22},"20",{"key":24,"text":158,"correct":26},"10",{"key":28,"text":160,"correct":22},"2",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":24,"analysis":30},847105,"职业道德是一种职业规范,受()普遍的认可。",[165,167,169],{"key":20,"text":166,"correct":22},"单位",{"key":24,"text":168,"correct":26},"社会",{"key":28,"text":170,"correct":22},"某个员工",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":20,"analysis":30},847106,"高炉顶放散管的高度应高出卷扬机绳轮工作台()m以上。",[175,177,179],{"key":20,"text":176,"correct":26},"5",{"key":24,"text":178,"correct":22},"4",{"key":28,"text":160,"correct":22},{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":28,"analysis":30},847107,"电除尘器中水煤气的含氧量,正常操作时应小于0.6%;大于0.6%时,应发出报警信号;达到()时,应立即切断电除尘器的电源;",[184,186,187],{"key":20,"text":185,"correct":22},"0.7%",{"key":24,"text":128,"correct":22},{"key":28,"text":188,"correct":26},"0.8%",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":20,"analysis":30},847108,"当铁合金电炉突然停电时,煤气净化设施应及时与电炉()隔断。",[193,195,197],{"key":20,"text":194,"correct":26},"有效",{"key":24,"text":196,"correct":22},"可靠",{"key":28,"text":198,"correct":22},"停电",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":20,"analysis":30},847109,"高炉煤气着火点是()℃",[203,205,207],{"key":20,"text":204,"correct":26},"700",{"key":24,"text":206,"correct":22},"550—650",{"key":28,"text":208,"correct":22},"630",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":28,"analysis":30},847110,"煤气放散管口应高出煤气管道、设备和走台4m,离地面不小于()m,管口应采取防雨、防堵塞措施。",[213,214,215],{"key":20,"text":178,"correct":22},{"key":24,"text":156,"correct":22},{"key":28,"text":158,"correct":26},{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":28,"analysis":30},847111,"为防止煤气管道积水,管道敷设时需设置()。",[220,222,224],{"key":20,"text":221,"correct":22},"管道加温装置",{"key":24,"text":223,"correct":22},"管道加力器",{"key":28,"text":225,"correct":26},"泠凝水排水器",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":24,"analysis":30},847112,"进入煤气设施内部检修,CO浓度不超过30mg\u002F㎥(24ppm)可以工作()。",[230,232,234],{"key":20,"text":231,"correct":22},"1h",{"key":24,"text":233,"correct":26},"长时间工作",{"key":28,"text":235,"correct":22},"0.5h",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":24,"analysis":30},847113,"架空敷设煤气管道气压强度试验的压力应为计算压力的()倍。",[240,242,244],{"key":20,"text":241,"correct":22},"1.25",{"key":24,"text":243,"correct":26},"1.15",{"key":28,"text":245,"correct":22},"1.5",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":24,"analysis":30},847114,"发生煤气中毒、着火、爆炸和大量泄漏煤气等事故,应立即报告()。",[250,252,254],{"key":20,"text":251,"correct":22},"车间主任",{"key":24,"text":253,"correct":26},"调度室和煤气防护站",{"key":28,"text":255,"correct":22},"值班长",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":24,"analysis":30},847115,"依据《工伤保险条例》的规定,享有工伤保险权利的主体是()。",[260,261,263],{"key":20,"text":136,"correct":22},{"key":24,"text":262,"correct":26},"职工、雇主",{"key":28,"text":264,"correct":22},"用人单位、职工",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":28,"analysis":30},847116,"煤气净化运行时氧含量异常超标,是由于电炉或煤气净化设施()而至。",[269,271,273],{"key":20,"text":270,"correct":22},"煤气质量",{"key":24,"text":272,"correct":22},"原料问题",{"key":28,"text":274,"correct":26},"封闭不严",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":20,"analysis":30},847117,"铁合金电炉用废烟气置换时,CO含量应控制在()以下。",[279,281,283],{"key":20,"text":280,"correct":26},"8%",{"key":24,"text":282,"correct":22},"10%",{"key":28,"text":284,"correct":22},"12.5%",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":28,"analysis":30},847118,"煤气柜用氮气进行置换后,取样分析气体含氧量()视为合格。",[289,291,293],{"key":20,"text":290,"correct":22},"≥6%",{"key":24,"text":292,"correct":22},"≥2%",{"key":28,"text":294,"correct":26},"≤2%",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":24,"analysis":30},847119,"煤气设施检修时,空间CO浓度在150PPm,检修人员连续作业时间不得超过()分钟。",[299,300,302],{"key":20,"text":158,"correct":22},{"key":24,"text":301,"correct":26},"15",{"key":28,"text":176,"correct":22},{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":24,"analysis":30},847120,"调压煤气放散管应控制放散,其管口高度应高出周围建筑物,一般距离地面不小于()m,所放散的煤气必须点燃,并有灭火设施。",[307,308,310],{"key":20,"text":158,"correct":22},{"key":24,"text":309,"correct":26},"30",{"key":28,"text":156,"correct":22},{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":24,"analysis":30},847121,"两条煤气管道如设同一排水器,其水封的有效高度按()计算。",[315,317,319],{"key":20,"text":316,"correct":22},"平均压力",{"key":24,"text":318,"correct":26},"最高压力",{"key":28,"text":320,"correct":22},"压力之和",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":20,"analysis":30},847122,"煤气发生炉水套用水总硬度不应超过()mgN\u002FL",[325,327,329],{"key":20,"text":326,"correct":26},"1",{"key":24,"text":328,"correct":22},"2.1",{"key":28,"text":330,"correct":22},"0.5",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":20,"analysis":30},847123,"煤气净化供电设施应有()电源。",[335,337,339],{"key":20,"text":336,"correct":26},"两路",{"key":24,"text":338,"correct":22},"双路",{"key":28,"text":340,"correct":22},"缓冲",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":20,"analysis":30},847124,"TRT进出口煤气管道放散管,必须高出煤气管道走台几米。",[345,347,349,351],{"key":20,"text":346,"correct":26},"、4M;",{"key":24,"text":348,"correct":22},"、3M;",{"key":28,"text":350,"correct":22},"、2M;",{"key":352,"text":353,"correct":22},"D","、5M",{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":20,"analysis":30},847125,"企业全员安全教育是面向全体管理人员、()的定期安全教育。",[358,360,362],{"key":20,"text":359,"correct":26},"生产作业人员",{"key":24,"text":361,"correct":22},"家属",{"key":28,"text":363,"correct":22},"职工和家属",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":20,"analysis":30},847126,"在鼓风机后的焦炉煤气系统,应设泄爆装置,设自动的连续式氧含量分析仪,煤气含氧量达()时报警,达()时切断电源。",[368,370,372],{"key":20,"text":369,"correct":26},"1%,2%",{"key":24,"text":371,"correct":22},"0.6%,1%",{"key":28,"text":373,"correct":22},"2%,5%",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":28,"analysis":30},847127,"()现象是指出口流速小于燃烧速度时,火焰就会缩入火孔而产生的燃烧现象。",[378,380,382],{"key":20,"text":379,"correct":22},"燃烧",{"key":24,"text":381,"correct":22},"脱火",{"key":28,"text":383,"correct":26},"回火",{"id":385,"libraryId":5,"type":15,"typeLabel":16,"stem":386,"options":387,"answer":20,"analysis":30},847128,"O2在煤气成分中是起()作用。",[388,390,392],{"key":20,"text":389,"correct":26},"助燃",{"key":24,"text":391,"correct":22},"不燃",{"key":28,"text":393,"correct":22},"可燃",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":24,"analysis":30},847129,"在煤气防护仪器的使用保养中,空气呼吸器压力低于()应即时到煤气防护站进行充气",[398,400,402],{"key":20,"text":399,"correct":22},"10Mpa",{"key":24,"text":401,"correct":26},"20Mpa",{"key":28,"text":403,"correct":22},"15MPa",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":352,"analysis":30},847130,"大于DN300的煤气管道设置隔断装置不应选择的操作开关是()",[408,410,412,414],{"key":20,"text":409,"correct":22},"电动",{"key":24,"text":411,"correct":22},"液动",{"key":28,"text":413,"correct":22},"气动",{"key":352,"text":415,"correct":26},"手动",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":20,"analysis":30},847131,"需要采取防喘震措施的煤气加压机类型是()。",[420,422,424],{"key":20,"text":421,"correct":26},"离心式或轴流式",{"key":24,"text":423,"correct":22},"罗茨鼓风机",{"key":28,"text":425,"correct":22},"活塞式压缩机",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":20,"analysis":30},847132,"一般情况下,煤气管道的设计流速一般不大于()m\u002Fs。",[430,431,432],{"key":20,"text":156,"correct":26},{"key":24,"text":158,"correct":22},{"key":28,"text":176,"correct":22},{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":20,"analysis":30},847133,"下列选项不属于蒸汽置换的缺点的是()。",[437,439,441],{"key":20,"text":438,"correct":26},"不适用于小系统置换",{"key":24,"text":440,"correct":22},"置换成本高",{"key":28,"text":442,"correct":22},"置换需要连续完成",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":20,"analysis":30},847134,"煤气加压站机组转子完全停止转动后()分钟,或从轴承中流出的油温低于()℃时,方可停止电动油泵的工作。",[447,449,451,453],{"key":20,"text":448,"correct":26},"20,45",{"key":24,"text":450,"correct":22},"30,45",{"key":28,"text":452,"correct":22},"20,50",{"key":352,"text":454,"correct":22},"30,50",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":20,"analysis":30},847135,"从安全生产的角度,()是指可能造成人员伤害、疾病、财产损失、作业环境破坏或其他损失的根源或状态。",[459,461,463],{"key":20,"text":460,"correct":26},"危险源",{"key":24,"text":462,"correct":22},"危险度",{"key":28,"text":464,"correct":22},"危险",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":28,"analysis":30},847136,"煤气柜检修应采用()",[469,471,473],{"key":20,"text":470,"correct":22},"蒸汽置换法",{"key":24,"text":472,"correct":22},"直接置换法",{"key":28,"text":474,"correct":26},"间接置换法",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":20,"analysis":30},847137,"气体在等温条件下,压力越大,它的体积就()。",[479,481,483],{"key":20,"text":480,"correct":26},"变小",{"key":24,"text":482,"correct":22},"变大",{"key":28,"text":484,"correct":22},"不变",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":20,"analysis":30},847138,"加压机或抽气机前的煤气设施应()检验壁厚,若壁厚小于安全限度,应采取措施后,才能继续使用。",[489,491,493],{"key":20,"text":490,"correct":26},"定期",{"key":24,"text":492,"correct":22},"不定期",{"key":28,"text":494,"correct":22},"随时",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":24,"analysis":30},847139,"从业人员应当严格遵守()。",[499,501,503],{"key":20,"text":500,"correct":22},"安全生产法律、法规",{"key":24,"text":502,"correct":26},"安全生产法律、法规、规章制度和操作规程",{"key":28,"text":504,"correct":22},"安全生产规章制度和操作规程",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":20,"analysis":30},847140,"稀油密封煤气柜密封油飞溅到活塞上,需要调整()。",[509,511,513],{"key":20,"text":510,"correct":26},"油泵出口油量",{"key":24,"text":512,"correct":22},"油泵启动次数",{"key":28,"text":514,"correct":22},"油水分离器",[516,519,522,524,527,530],{"id":517,"name":518,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":520,"name":521,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":523,"name":521,"category":7,"favorite":8},336,{"id":525,"name":526,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":528,"name":529,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":531,"name":532,"category":7,"favorite":8},353,"(N1)叉车司机"]