[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-464-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":527},{"id":5,"name":6,"category":7,"favorite":8},464,"煤气作业","特种作业",0,2,50,1632,[13,31,41,51,61,71,84,94,104,114,124,133,143,153,163,173,183,193,205,215,225,235,245,255,265,275,285,295,307,317,327,337,347,357,367,377,387,396,406,416,426,437,447,457,467,477,487,497,507,517],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},846941,1,"单选题","《工业企业煤气安全规程》规定,作业环境CO最高允许浓度为()PPM",[19,23,27],{"key":20,"text":21,"correct":22},"A","24",true,{"key":24,"text":25,"correct":26},"B","100",false,{"key":28,"text":29,"correct":26},"C","28","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":24,"analysis":30},846942,"进入煤气设备内部工作时,所用照明电压不得超过()V",[35,37,39],{"key":20,"text":36,"correct":26},"24V",{"key":24,"text":38,"correct":22},"12V",{"key":28,"text":40,"correct":26},"36V",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":28,"analysis":30},846943,"特殊情况下煤气管道距离房屋建筑的最小水平净距不小于()m。",[45,47,49],{"key":20,"text":46,"correct":26},"、1",{"key":24,"text":48,"correct":26},"、5",{"key":28,"text":50,"correct":22},"、3",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":28,"analysis":30},846944,"煤气站房内应设有()监测装置,并把信号传送到管理室内。",[55,57,59],{"key":20,"text":56,"correct":26},"硫化氢",{"key":24,"text":58,"correct":26},"二氧化碳",{"key":28,"text":60,"correct":22},"一氧化碳",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":20,"analysis":30},846945,"煤气危险区依据危险程度分为三类,下列属于三类危险区域的是()",[65,67,69],{"key":20,"text":66,"correct":22},"煤气设备附近",{"key":24,"text":68,"correct":26},"带煤气抽堵板",{"key":28,"text":70,"correct":26},"开关煤气插板",{"id":72,"libraryId":5,"type":15,"typeLabel":16,"stem":73,"options":74,"answer":28,"analysis":30},846946,"TRT轴封发生煤气泄漏事故现场,疏散人员可通过旗帜、树枝或利用手帕等迅速辨明风向,并向()撤离。",[75,77,79,81],{"key":20,"text":76,"correct":26},"、侧风向;",{"key":24,"text":78,"correct":26},"、下风向;",{"key":28,"text":80,"correct":22},"、上风向或侧风向;",{"key":82,"text":83,"correct":26},"D","、上风向",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":20,"analysis":30},846947,"依据《安全生产法》的规定,生产经营单位与从业人员订立协议,免除或者减轻其对从业人员因生产安全事故伤亡依法应承担的责任的,该协议无效;对生产经营单位的()处二万元以上十万元以下的罚款。",[88,90,92],{"key":20,"text":89,"correct":22},"主要负责人、个人经营的投资人",{"key":24,"text":91,"correct":26},"直接责任人、相关负责人",{"key":28,"text":93,"correct":26},"主要负责人、直接责任人",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":30},846948,"固定带应能将导气管或中压管固定砸在佩戴者身后或侧面而不影响操作,宽度不小于()。",[98,100,102],{"key":20,"text":99,"correct":26},"32mm",{"key":24,"text":101,"correct":22},"40mm",{"key":28,"text":103,"correct":26},"36mm",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":28,"analysis":30},846949,"煤气柜排水器主要用来排出柜内()。",[108,110,112],{"key":20,"text":109,"correct":26},"水",{"key":24,"text":111,"correct":26},"污物",{"key":28,"text":113,"correct":22},"水和污物",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":24,"analysis":30},846950,"氧气转炉风机房正常通风换气每小时应不少于7次,事故通风换气每小时应不少于()次。",[118,120,122],{"key":20,"text":119,"correct":26},"10",{"key":24,"text":121,"correct":22},"20",{"key":28,"text":123,"correct":26},"15",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":20,"analysis":30},846951,"按照《工业企业煤气安全规程》规定,吹扫或引气过程中,严禁在煤气设施上栓、拉电焊线,煤气设施周围()米内严禁火源",[128,130,132],{"key":20,"text":129,"correct":22},"40",{"key":24,"text":131,"correct":26},"50",{"key":28,"text":121,"correct":26},{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":20,"analysis":30},846952,"煤气管道上设置补偿器的作用是()。",[137,139,141],{"key":20,"text":138,"correct":22},"消除应力",{"key":24,"text":140,"correct":26},"固定作用",{"key":28,"text":142,"correct":26},"方便连接",{"id":144,"libraryId":5,"type":15,"typeLabel":16,"stem":145,"options":146,"answer":24,"analysis":30},846953,"干式煤气柜活塞上部应按储存气体特征设置()监测装置,其监测信号应送至控制室并设有声光报警显示和记录。",[147,149,151],{"key":20,"text":148,"correct":26},"悬挂式",{"key":24,"text":150,"correct":22},"固定式",{"key":28,"text":152,"correct":26},"移动式",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":24,"analysis":30},846954,"眼镜阀不宜单独使用,应设在密封蝶阀或闸阀的(),操作盲板阀前,首先要关闭密封蝶阀或闸阀,盲板阀开关必须到位。",[157,159,161],{"key":20,"text":158,"correct":26},"前面或后面",{"key":24,"text":160,"correct":22},"后面",{"key":28,"text":162,"correct":26},"前面",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":24,"analysis":30},846955,"煤气净化运行时,净化设施与罗茨风机压差过大异常时,应首先判断设施内有()现象。",[167,169,171],{"key":20,"text":168,"correct":26},"抽真空",{"key":24,"text":170,"correct":22},"堵塞",{"key":28,"text":172,"correct":26},"设施泄漏",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":28,"analysis":30},846956,"回火是指(),火焰将回到烧嘴中去。",[177,179,181],{"key":20,"text":178,"correct":26},"混合气体的流速比火焰相等时",{"key":24,"text":180,"correct":26},"混合气体的流速比火焰快时",{"key":28,"text":182,"correct":22},"混合气体的流速比火焰慢时",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":24,"analysis":30},846957,"煤气设备设施的泄爆装置的防爆膜,应在容器内不超过()时,自行破裂。",[187,189,191],{"key":20,"text":188,"correct":26},"10%",{"key":24,"text":190,"correct":22},"25%",{"key":28,"text":192,"correct":26},"15%",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":28,"analysis":30},846958,"如果TRT发电机着火,采取方法不正确的是()",[197,199,201,203],{"key":20,"text":198,"correct":26},"、紧急停机并断上级联络开关;",{"key":24,"text":200,"correct":26},"、通知调度请求支援;",{"key":28,"text":202,"correct":22},"、发电机着火禁止用消防水灭火;",{"key":82,"text":204,"correct":26},"、停油泵控制火势蔓延",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":28,"analysis":30},846959,"加压站单台加压机本体检修时,(),惰性气体置换煤气合格后检修。",[209,211,213],{"key":20,"text":210,"correct":26},"关闭加压机进口调节阀",{"key":24,"text":212,"correct":26},"关闭加压机的进、出口管道的蝶阀",{"key":28,"text":214,"correct":22},"加压机的进、出口管道必须与煤气总管可靠切断",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":24,"analysis":30},846960,"要预防煤气燃烧、爆炸,重点还是放在控制()。",[219,221,223],{"key":20,"text":220,"correct":26},"可燃物",{"key":24,"text":222,"correct":22},"引火源",{"key":28,"text":224,"correct":26},"助燃物",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":20,"analysis":30},846961,"进行动火补焊时,一般规定,易燃易爆气体中含氧量小于()为合格。",[229,231,233],{"key":20,"text":230,"correct":22},"1%",{"key":24,"text":232,"correct":26},"0.5%",{"key":28,"text":234,"correct":26},"2%",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":20,"analysis":30},846962,"中度CO中毒者,应及时进行()急救。",[239,241,243],{"key":20,"text":240,"correct":22},"现场",{"key":24,"text":242,"correct":26},"送医院",{"key":28,"text":244,"correct":26},"冷冻法",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":20,"analysis":30},846963,"竖炉废气出口,以及Korfarc炉炉盖弯管出口,应设置()成分连续分析系统",[249,251,253],{"key":20,"text":250,"correct":22},"废气",{"key":24,"text":252,"correct":26},"煤气",{"key":28,"text":254,"correct":26},"烟气",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":24,"analysis":30},846964,"《安全生产事故隐患排查治理暂行规定》(总局令16号)指出,事故隐患分为()。",[259,261,263],{"key":20,"text":260,"correct":26},"一般事故隐患和重大事故隐患及特大事故隐患",{"key":24,"text":262,"correct":22},"一般事故隐患和重大事故隐患",{"key":28,"text":264,"correct":26},"一般事故隐患、较大事故隐患、重大事故隐患及特大事故隐患",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":24,"analysis":30},846965,"在煤气地区作业时,一氧化碳浓度超过()时必须戴面具作业",[269,271,273],{"key":20,"text":270,"correct":26},"100PPm",{"key":24,"text":272,"correct":22},"160PPm",{"key":28,"text":274,"correct":26},"50PPm",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":24,"analysis":30},846966,"煤气设施检修时,临时照明灯的工作电压,不得超过()。",[279,281,283],{"key":20,"text":280,"correct":26},"36∨",{"key":24,"text":282,"correct":22},"12∨",{"key":28,"text":284,"correct":26},"24∨",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":24,"analysis":30},846967,"净化后煤气,在输送用户前,煤气成分应做()。",[289,291,293],{"key":20,"text":290,"correct":26},"煤气检测",{"key":24,"text":292,"correct":22},"化验分析",{"key":28,"text":294,"correct":26},"爆鸣试验",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":82,"analysis":30},846968,"关于TRT电动运行下列说法不正确的是()",[299,301,303,305],{"key":20,"text":300,"correct":26},"、电动运行需通知高炉及变电站;",{"key":24,"text":302,"correct":26},"、电动运行时间不超过4小时以上;",{"key":28,"text":304,"correct":26},"、电动运行要注意煤气出口温度及振动情况;",{"key":82,"text":306,"correct":22},"、电动运行要注意转速变化情况防止超速",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":20,"analysis":30},846969,"煤气管道与水管、热力管、燃油管和不燃气体管在同一支柱或栈桥上敷设时,其上下敷设的垂直净距不宜小于()mm。",[311,313,315],{"key":20,"text":312,"correct":22},"250",{"key":24,"text":314,"correct":26},"150",{"key":28,"text":316,"correct":26},"350",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":24,"analysis":30},846970,"设置在稀油密封型干式煤气柜筒体上部,为防止活塞冲顶的最后一道煤气自动放散装置,称为()放散管。",[321,323,325],{"key":20,"text":322,"correct":26},"安全",{"key":24,"text":324,"correct":22},"紧急",{"key":28,"text":326,"correct":26},"过剩",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":20,"analysis":30},846971,"气体检测报警仪可以()预先设定报警浓度值",[331,333,335],{"key":20,"text":332,"correct":22},"根据有关法规标准和现场情况",{"key":24,"text":334,"correct":26},"根据其它企业",{"key":28,"text":336,"correct":26},"随机",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":24,"analysis":30},846972,"架空煤气管道靠近高温热源敷设,以及管道下面经常有装载炽热物体车辆停留时,应采取()措施。",[341,343,345],{"key":20,"text":342,"correct":26},"防火",{"key":24,"text":344,"correct":22},"隔热",{"key":28,"text":346,"correct":26},"防爆",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":24,"analysis":30},846973,"炉容大于等于1500立方米的热风炉净煤气支管的煤气压力应大于等于()KPa。",[351,353,355],{"key":20,"text":352,"correct":26},"3.43",{"key":24,"text":354,"correct":22},"6",{"key":28,"text":356,"correct":26},"4.9",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":24,"analysis":30},846974,"补偿器的导流管应()煤气管道的坡度排水方向安装。",[361,363,365],{"key":20,"text":362,"correct":26},"逆向",{"key":24,"text":364,"correct":22},"顺着",{"key":28,"text":366,"correct":26},"视情况而定",{"id":368,"libraryId":5,"type":15,"typeLabel":16,"stem":369,"options":370,"answer":28,"analysis":30},846975,"煤气发生炉是以固体燃料为原料,采用某种气化剂,进行()反应,使固体燃料转化为气体燃料的设备",[371,373,375],{"key":20,"text":372,"correct":26},"物理",{"key":24,"text":374,"correct":26},"化学",{"key":28,"text":376,"correct":22},"物理化学",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":28,"analysis":30},846976,"进行煤气相关作业的操作工和检修人员应熟悉煤气中毒急救方法,发生中毒后,有关人员应立即和()取得联系,并采取急救措施。",[381,383,385],{"key":20,"text":382,"correct":26},"医院",{"key":24,"text":384,"correct":26},"车间领导",{"key":28,"text":386,"correct":22},"煤气防护站",{"id":388,"libraryId":5,"type":15,"typeLabel":16,"stem":389,"options":390,"answer":24,"analysis":30},846977,"CO气体检测报警仪的检测与报警响应时间应在()s以内",[391,393,395],{"key":20,"text":392,"correct":26},"120",{"key":24,"text":394,"correct":22},"60",{"key":28,"text":121,"correct":26},{"id":397,"libraryId":5,"type":15,"typeLabel":16,"stem":398,"options":399,"answer":20,"analysis":30},846978,"煤气柜柜顶一般每()点检一次。",[400,402,404],{"key":20,"text":401,"correct":22},"周",{"key":24,"text":403,"correct":26},"日",{"key":28,"text":405,"correct":26},"月",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":20,"analysis":30},846979,"氢气管道强度试验合格后,使用惰性气体或洁净空气吹洗,其流速不小于(),直至合格.",[410,412,414],{"key":20,"text":411,"correct":22},"20m\u002Fs",{"key":24,"text":413,"correct":26},"10m\u002Fs",{"key":28,"text":415,"correct":26},"30m\u002Fs",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":24,"analysis":30},846980,"安全生产监督管理部门在生产经营单位现场检查时,发现现场作业人员有未按照要求佩戴、使用劳动防护用品的情况,应当()。",[420,422,424],{"key":20,"text":421,"correct":26},"责令立即排除",{"key":24,"text":423,"correct":22},"当场予以纠正",{"key":28,"text":425,"correct":26},"责令停止生产作业",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":20,"analysis":30},846981,"进入TRT煤气管道内检查导流板作业时其照明灯的安全电压为()",[430,432,434,436],{"key":20,"text":431,"correct":22},"12V;",{"key":24,"text":433,"correct":26},"32V;",{"key":28,"text":435,"correct":26},"36V;",{"key":82,"text":36,"correct":26},{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":24,"analysis":30},846982,"煤气设备或单独的管段上人孔一般不少于()个。",[441,443,445],{"key":20,"text":442,"correct":26},"1",{"key":24,"text":444,"correct":22},"2",{"key":28,"text":446,"correct":26},"3",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":20,"analysis":30},846983,"转炉煤气回收系统的设备、风机房、煤气柜以及可能泄漏煤气的其他设备,应位于车间()风向的上风侧。",[451,453,455],{"key":20,"text":452,"correct":22},"常年最小频率",{"key":24,"text":454,"correct":26},"夏季最小频率",{"key":28,"text":456,"correct":26},"夏季最大频率",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":28,"analysis":30},846984,"煤气设备设施长时间停用,再启用时,应重新对其进行系统()工作。",[461,463,465],{"key":20,"text":462,"correct":26},"严密性试验",{"key":24,"text":464,"correct":26},"安全检查",{"key":28,"text":466,"correct":22},"全面性验收",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":28,"analysis":30},846985,"转炉煤气是一种()的可燃性有毒气体。",[471,473,475],{"key":20,"text":472,"correct":26},"有味无色",{"key":24,"text":474,"correct":26},"有色无味",{"key":28,"text":476,"correct":22},"无色无味",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":28,"analysis":30},846986,"盲板作业中要使用千斤顶撑开法兰,在以下叙述中哪项需改进()。",[481,483,485],{"key":20,"text":482,"correct":26},".作业法兰两侧设斜鱼子高度300mm",{"key":24,"text":484,"correct":26},".作业法兰两侧设斜鱼子1至3对",{"key":28,"text":486,"correct":22},".两斜鱼子间距为500mm",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":20,"analysis":30},846987,"将天然气加压至15—20MPa,并以气态储存在容器内称为压缩天然气,其英文缩写是()。",[491,493,495],{"key":20,"text":492,"correct":22},"CNG",{"key":24,"text":494,"correct":26},"LPG",{"key":28,"text":496,"correct":26},"COG",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":20,"analysis":30},846988,"焦炉煤气制氢压缩机各级出口冷却后焦炉煤气温度().",[501,503,505],{"key":20,"text":502,"correct":22},"≤45℃",{"key":24,"text":504,"correct":26},"≤30℃",{"key":28,"text":506,"correct":26},"≤60℃",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":28,"analysis":30},846989,"逃生呼吸器可用于()。",[511,513,515],{"key":20,"text":512,"correct":26},"进入高浓度毒气环境短时间作业",{"key":24,"text":514,"correct":26},"进入低浓度毒气环境中作业",{"key":28,"text":516,"correct":22},"从有害环境中撤离",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":20,"analysis":30},846990,"复合气瓶外观检查,损伤分为三级,一级损伤()。",[521,523,525],{"key":20,"text":522,"correct":22},"轻微损伤,不会影响对气瓶的安全型和继续使用产生影响。",{"key":24,"text":524,"correct":26},"磨损、划伤严重,经修复后,水压试验有鼓包和脱落的做报废。",{"key":28,"text":526,"correct":26},"受过撞击损伤或热损伤,化学腐蚀变形的做报废处理。",[528,531,534,536,539,542],{"id":529,"name":530,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":532,"name":533,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":535,"name":533,"category":7,"favorite":8},336,{"id":537,"name":538,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":540,"name":541,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":543,"name":544,"category":7,"favorite":8},353,"(N1)叉车司机"]