[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":545},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,9,50,1668,[13,34,44,56,66,76,88,98,108,118,128,140,150,162,174,186,198,210,220,230,240,250,260,271,281,293,303,313,321,331,341,351,361,371,381,391,401,411,421,431,443,453,463,473,482,491,501,513,523,535],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},716766,1,"单选题","变压器气体保护用于反应油箱漏油等造成油面降低以及()。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A",".变压器油箱内部的各种故障",true,{"key":24,"text":25,"correct":26},"B",".引出线的套管闪络故障",false,{"key":28,"text":29,"correct":26},"C",".引出线上的相间故障",{"key":31,"text":32,"correct":26},"D",".过负荷","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},716767,"定时限过电流保护近后备灵敏系数要求()。",[38,40,42],{"key":20,"text":39,"correct":26},".大于1.2",{"key":24,"text":41,"correct":26},".小于1.2",{"key":28,"text":43,"correct":22},".大于1.3-1.5",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":28,"analysis":33},716768,"变压器故障分为油箱外故障和()两大类。",[48,50,52,54],{"key":20,"text":49,"correct":26},".绝缘故障",{"key":24,"text":51,"correct":26},".低压套管故障",{"key":28,"text":53,"correct":22},".油箱内故障",{"key":31,"text":55,"correct":26},".高压套管故障",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":20,"analysis":33},716769,"电动机纵差动保护接线,一侧电流互感器接于中性点侧,另一侧接于()。",[60,62,64],{"key":20,"text":61,"correct":22},".机端对应各相上",{"key":24,"text":63,"correct":26},".中性点接地线上",{"key":28,"text":65,"correct":26},".电动机绕组上",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":28,"analysis":33},716770,"电动机采用熔断器-高压接触器控制时,电流速断保护增设的延时时间应()熔断器的熔断时间。",[70,72,74],{"key":20,"text":71,"correct":26},".等于",{"key":24,"text":73,"correct":26},".小于",{"key":28,"text":75,"correct":22},".大于",{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":20,"analysis":33},716771,"跌落式熔断器在短路电流流过后,装有熔丝的管子自由落下,是一种(C)保护装置。",[80,82,84,86],{"key":20,"text":81,"correct":22},".短路和过负荷",{"key":24,"text":83,"correct":26},".零序电流",{"key":28,"text":85,"correct":26},".电压",{"key":31,"text":87,"correct":26},".功率方向",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":28,"analysis":33},716772,"变压器低电压起动的过电流保护的电压元件接在降压变压器低压侧母线电压互感器二次侧线电压上,反应三相线电压()时动作。",[92,94,96],{"key":20,"text":93,"correct":26},".不变",{"key":24,"text":95,"correct":26},".升高",{"key":28,"text":97,"correct":22},".降低",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":28,"analysis":33},716773,"电流互感器二次绕组与电流元件线圈之间的连接方式称为电流互感器的()。",[102,104,106],{"key":20,"text":103,"correct":26},".安装接线",{"key":24,"text":105,"correct":26},".连接组别",{"key":28,"text":107,"correct":22},".接线方式",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":24,"analysis":33},716774,"微机保护中电流、电压继电器由()实现。",[112,114,116],{"key":20,"text":113,"correct":26},".微型电流、电压继电器",{"key":24,"text":115,"correct":22},".软件算法",{"key":28,"text":117,"correct":26},".集成电路电流、电压继电器",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},716775,"自动重合闸动作后应(),以准备好再次动作。",[122,124,126],{"key":20,"text":123,"correct":22},".自动复归",{"key":24,"text":125,"correct":26},".手动复归",{"key":28,"text":127,"correct":26},".先手动复归,再自动起动",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":24,"analysis":33},716776,"常用的变压器相间短路的后备保护有过电流保护、低电压起动的过电流保护、复合电压起动的过电流保护、()、阻抗保护等。",[132,134,136,138],{"key":20,"text":133,"correct":26},".气体保护",{"key":24,"text":135,"correct":22},".负序过电流保护",{"key":28,"text":137,"correct":26},".变压器差动保护",{"key":31,"text":139,"correct":26},".电流速断保护",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":28,"analysis":33},716777,"信号继电器在继电保护中的主要作用为()。",[144,146,148],{"key":20,"text":145,"correct":26},".启动保护",{"key":24,"text":147,"correct":26},".增加触点数量和触点容量",{"key":28,"text":149,"correct":22},".发出动作信号",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":24,"analysis":33},716778,"某变电站采用低压母线分段备自投接线方式,当低压第I段母线失压后,发跳闸指令跳第I段母线所连主供电源,但开关拒动,据分析此时()。",[154,156,158,160],{"key":20,"text":155,"correct":26},".自投装置将改发合闸指令",{"key":24,"text":157,"correct":22},".自投装置不再将备用电源投入",{"key":28,"text":159,"correct":26},".自投装置将一直发跳闸指令,直到成功",{"key":31,"text":161,"correct":26},".自投装置将延时投入备用电源",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":31,"analysis":33},716779,"距离保护装置反应()而动作。",[166,168,170,172],{"key":20,"text":167,"correct":26},".测量阻抗增大",{"key":24,"text":169,"correct":26},".电压降低",{"key":28,"text":171,"correct":26},".电流增大",{"key":31,"text":173,"correct":22},".测量阻抗降低",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":31,"analysis":33},716780,"某35kV系统通过输电线路向负荷供电,当线路末端发生三相短路时,短路电流为3.5kA,当同一地点发生两相短路时,其短路电流为()。",[178,180,182,184],{"key":20,"text":179,"correct":26},".6.06k",{"key":24,"text":181,"correct":26},".4.95k",{"key":28,"text":183,"correct":26},".1.77k",{"key":31,"text":185,"correct":22},".3.03k",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":24,"analysis":33},716781,"某变压器差动保护采用带速饱和变流器的差动继电器,当空载合闸时,由于变压器容量较大,励磁涌流与故障电流相当,此时保护()。",[190,192,194,196],{"key":20,"text":191,"correct":26},".将可靠跳闸",{"key":24,"text":193,"correct":22},".将被速饱和变流器闭锁",{"key":28,"text":195,"correct":26},".将发跳闸信号",{"key":31,"text":197,"correct":26},".将延时跳闸",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":28,"analysis":33},716782,"变电站的主要调压手段是调节有载调压变压器分接头位置和()。",[202,204,206,208],{"key":20,"text":203,"correct":26},".采用备用电源自投装置",{"key":24,"text":205,"correct":26},".低频减负荷",{"key":28,"text":207,"correct":22},".控制无功功率补偿电容器",{"key":31,"text":209,"correct":26},".采用自动重合闸装置",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":33},716783,"发电厂、变电站的电气系统,按其作用分为一次系统和()。",[214,216,218],{"key":20,"text":215,"correct":26},".模拟系统",{"key":24,"text":217,"correct":22},".二次系统",{"key":28,"text":219,"correct":26},".数字系统",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":20,"analysis":33},716784,"电动机负序电流保护,当I2&gt;1.2I1时()负序电流保护(I2负序电流,I1正序电流)。",[224,226,228],{"key":20,"text":225,"correct":22},".闭锁",{"key":24,"text":227,"correct":26},".开放",{"key":28,"text":229,"correct":26},".起动",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":24,"analysis":33},716785,"重合闸成功率计算为()。",[234,236,238],{"key":20,"text":235,"correct":26},".重合闸失败次数除以重合闸应该动作的总次数的百分数",{"key":24,"text":237,"correct":22},".重合闸成功次数除以重合闸应该动作的总次数的百分数",{"key":28,"text":239,"correct":26},".重合闸成功次数除以重合闸失败次数的百分数",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":20,"analysis":33},716786,"电动机纵差动保护中还设有差动电流速断保护,动作电流一般可取()倍额定电流。",[244,246,248],{"key":20,"text":245,"correct":22},".3-8",{"key":24,"text":247,"correct":26},".1-2",{"key":28,"text":249,"correct":26},".9-10",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":20,"analysis":33},716787,"变压器出现励磁涌流时,如不采取措施,差动保护将()。",[254,256,258],{"key":20,"text":255,"correct":22},".误动作",{"key":24,"text":257,"correct":26},".正确动作",{"key":28,"text":259,"correct":26},".不动作",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":24,"analysis":33},716788,"变压器异常运行包括过负荷、外部短路引起的过电流及()等。",[264,266,268,269],{"key":20,"text":265,"correct":26},".一相绕组匝间短路",{"key":24,"text":267,"correct":22},".油箱漏油等造成油面降低",{"key":28,"text":25,"correct":26},{"key":31,"text":270,"correct":26},".绕组间的相间故障",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":28,"analysis":33},716789,"电流互感器的接线方式中,三相都装有电流互感器以及相应的电流元件,能够反应三相电流的接线方式为()。",[275,277,279],{"key":20,"text":276,"correct":26},".两相电流差接线",{"key":24,"text":278,"correct":26},".两相不完全星形接线",{"key":28,"text":280,"correct":22},".三相完全星形接线",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":20,"analysis":33},716790,"对于容量在()的油浸式变压器以及400kVA及以上的车间内油浸式变压器,应装设瓦斯保护。",[285,287,289,291],{"key":20,"text":286,"correct":22},".800kV及以上",{"key":24,"text":288,"correct":26},".800kV及以下",{"key":28,"text":290,"correct":26},".500kV及以上",{"key":31,"text":292,"correct":26},".500kV及以下",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":20,"analysis":33},716791,"瞬时电流速断保护动作电流的整定原则为()。",[297,299,301],{"key":20,"text":298,"correct":22},".躲过本线路末端短路可能出现的最大短路电流",{"key":24,"text":300,"correct":26},".躲过本线路末端短路可能出现的最小短路电流",{"key":28,"text":302,"correct":26},".躲过本线路末端短路可能出现的最大负荷电流",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":20,"analysis":33},716792,"设备的防触电保护不仅靠基本绝缘,还具有像双重绝缘或加强绝缘这样的附加安全措施。这样的设备属于()设备。",[307,309,311],{"key":20,"text":308,"correct":22},"Ⅱ类",{"key":24,"text":310,"correct":26},"I类",{"key":28,"text":312,"correct":26},"Ⅲ类",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":24,"analysis":33},716793,"发电厂、变电站的电气系统,按其作用分为()和二次系统。",[317,318,320],{"key":20,"text":215,"correct":26},{"key":24,"text":319,"correct":22},".一次系统",{"key":28,"text":219,"correct":26},{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":28,"analysis":33},716794,"室内电气装置或设备发生火灾时应尽快(),并及时正确选用灭火器进行扑救。",[325,327,329],{"key":20,"text":326,"correct":26},"、迅速灭火",{"key":24,"text":328,"correct":26},"、拉开开关",{"key":28,"text":330,"correct":22},"、拉掉开关切断电源",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":28,"analysis":33},716795,"变压器过负荷保护一般接(),当过负荷时经过延时发出信号。",[335,337,339],{"key":20,"text":336,"correct":26},".三相电流",{"key":24,"text":338,"correct":26},".二相电流",{"key":28,"text":340,"correct":22},".一相电流",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":28,"analysis":33},716796,"电力系统中作为联系发电厂与用户的中间环节,具有汇集电能和分配电能、变换电压和交换功率等功能的称为()。",[345,347,349],{"key":20,"text":346,"correct":26},".发电厂",{"key":24,"text":348,"correct":26},".变压器",{"key":28,"text":350,"correct":22},".变电站",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":20,"analysis":33},716797,"电力系统中母线和变压器发生故障,一般()重合闸。",[355,357,359],{"key":20,"text":356,"correct":22},".不采用",{"key":24,"text":358,"correct":26},".必须采用",{"key":28,"text":360,"correct":26},".根据实际情况采用",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":28,"analysis":33},716798,"跌落式熔断器主要用作配电变压器、()、电容组、架空线路分段或分支线路的短路故障保护。",[365,367,369],{"key":20,"text":366,"correct":26},".远距离电缆线路",{"key":24,"text":368,"correct":26},".高压输电线路",{"key":28,"text":370,"correct":22},".短段电缆线路",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":28,"analysis":33},716799,"电流互感器二次回路不能装设(),不设置切换回路,防止电流互感器二次回路开路。",[375,377,379],{"key":20,"text":376,"correct":26},".接地点",{"key":24,"text":378,"correct":26},".继电保护",{"key":28,"text":380,"correct":22},".熔断器",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":28,"analysis":33},716800,"理想电流互感器,励磁电流应等于()。",[385,387,389],{"key":20,"text":386,"correct":26},".短路电流",{"key":24,"text":388,"correct":26},".负荷电流",{"key":28,"text":390,"correct":22},".零",{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":20,"analysis":33},716801,"高压电动机最严重的故障是(),将引起电动机本身绕组绝缘严重损坏、铁芯烧伤,造成供电电网电压降低,影响或破坏其他用户的正常工作。",[395,397,399],{"key":20,"text":396,"correct":22},".定子绕组的相间短路故障",{"key":24,"text":398,"correct":26},".过负荷引起的过电流",{"key":28,"text":400,"correct":26},".一相绕组的匝间短路",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":28,"analysis":33},716802,"变压器相间短路的后备保护作为变压器差动保护或()和气体保护的后备保护。",[405,407,409,410],{"key":20,"text":406,"correct":26},".零序电流保护",{"key":24,"text":408,"correct":26},".过电流保护",{"key":28,"text":139,"correct":22},{"key":31,"text":135,"correct":26},{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":28,"analysis":33},716803,"定时限过电流保护的动作电流较小,但必须保证系统在()时不动作。",[415,417,419],{"key":20,"text":416,"correct":26},"发生单相短路",{"key":24,"text":418,"correct":26},"发生两相短路",{"key":28,"text":420,"correct":22},"正常运行最大负荷",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":24,"analysis":33},716804,"当低电压继电器返回时,动断触点()。",[425,427,429],{"key":20,"text":426,"correct":26},".闭合",{"key":24,"text":428,"correct":22},".断开",{"key":28,"text":430,"correct":26},".任意位置",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":20,"analysis":33},716805,"备用电源自动投入装置工作时,当工作母线不论任何原因电压消失,()均应投入。",[435,437,439,441],{"key":20,"text":436,"correct":22},".备用电源",{"key":24,"text":438,"correct":26},".备用母线",{"key":28,"text":440,"correct":26},".工作线路",{"key":31,"text":442,"correct":26},".工作变压器",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":20,"analysis":33},716806,"电动机的过负荷保护的动作对象可以根据需要设置动作于()或动作于信号。",[447,449,451],{"key":20,"text":448,"correct":22},".闭锁保护",{"key":24,"text":450,"correct":26},".瞬时跳闸",{"key":28,"text":452,"correct":26},".延时跳闸",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":20,"analysis":33},716807,"瞬时电流速断保护对线路的保护范围的影响()。",[457,459,461],{"key":20,"text":458,"correct":22},".与系统的运行方式和短路类型有关",{"key":24,"text":460,"correct":26},".与系统的运行方式和短路类型无直接关系",{"key":28,"text":462,"correct":26},".无论系统的运行方式和短路类型如何,范围均相同",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":20,"analysis":33},716808,"瞬时电流速断保护的灵敏度用()衡量。",[467,469,471],{"key":20,"text":468,"correct":22},".最小保护范围",{"key":24,"text":470,"correct":26},".最大保护范围",{"key":28,"text":472,"correct":26},".线路长度",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":28,"analysis":33},716809,"电流互感器常用的接线方式有三相完全星形接线、两相不完全星形接线及()等。",[477,479,481],{"key":20,"text":478,"correct":26},".两相完全星形接线",{"key":24,"text":480,"correct":26},".三相不完全星形接线",{"key":28,"text":276,"correct":22},{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":28,"analysis":33},716810,"电力系统中性点运行方式是指电力系统中发电机或()的中性点的接地方式。",[486,488,490],{"key":20,"text":487,"correct":26},".电流互感器",{"key":24,"text":489,"correct":26},".电压互感器",{"key":28,"text":348,"correct":22},{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":28,"analysis":33},716811,"电动机电流速断保护高定值按照()整定。",[495,497,499],{"key":20,"text":496,"correct":26},".躲过电动机的最小起动电流",{"key":24,"text":498,"correct":26},".躲过电动机的最大负荷电流",{"key":28,"text":500,"correct":22},".躲过电动机的最大起动电流",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":24,"analysis":33},716812,"变压器气体保护的主要元件是气体继电器,又称()。",[505,507,509,511],{"key":20,"text":506,"correct":26},".电流继电器",{"key":24,"text":508,"correct":22},".瓦斯继电器",{"key":28,"text":510,"correct":26},".电压继电器",{"key":31,"text":512,"correct":26},".中间继电器",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":24,"analysis":33},716813,"下列保护中()用于反应电动机起动时间过长。",[517,519,521],{"key":20,"text":518,"correct":26},".低电压保护",{"key":24,"text":520,"correct":22},".起动时间过长保护",{"key":28,"text":522,"correct":26},".负序电流保护",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":31,"analysis":33},716814,"备用电源自动投入装置动作时间应以负荷停电时间尽可能短为原则,以()。",[527,529,531,533],{"key":20,"text":528,"correct":26},".提高自投成功率",{"key":24,"text":530,"correct":26},".降低设备故障率",{"key":28,"text":532,"correct":26},".提高故障点的绝缘恢复时间",{"key":31,"text":534,"correct":22},".减少电动机的自起动时间",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":24,"analysis":33},716815,"高压电动机通常装设()或电流速断保护、负序电流保护、起动时间过长保护、过热保护、堵转保护、过电流保护、单相接地保护、低电压保护等。",[539,541,543],{"key":20,"text":540,"correct":26},".瓦斯保护",{"key":24,"text":542,"correct":22},".纵差动保护",{"key":28,"text":544,"correct":26},".距离保护",[546,549,552,554,557,560],{"id":547,"name":548,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":550,"name":551,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":553,"name":551,"category":7,"favorite":8},336,{"id":555,"name":556,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":558,"name":559,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":561,"name":562,"category":7,"favorite":8},353,"(N1)叉车司机"]