[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":562},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,8,50,1668,[13,34,44,54,64,74,84,96,108,120,132,142,152,162,172,182,192,204,214,225,235,247,257,267,277,289,301,313,321,333,343,353,365,376,388,400,412,424,436,446,456,468,480,492,502,512,522,532,540,550],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},716716,1,"单选题","距离保护装置测量阻抗小于整定阻抗时,说明()。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A",".短路点在保护区内,保护动作",true,{"key":24,"text":25,"correct":26},"B",".短路点在保护区外,保护动作",false,{"key":28,"text":29,"correct":26},"C",".短路点在保护区内,保护不动作",{"key":31,"text":32,"correct":26},"D",".短路点在保护区外,保护不动作","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},716717,"中间继电器的文字符号表示为()。",[38,40,42],{"key":20,"text":39,"correct":26},".KV",{"key":24,"text":41,"correct":22},".KA",{"key":28,"text":43,"correct":26},".KM",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":28,"analysis":33},716718,"变压器空载合闸后,产生的励磁涌流随时间逐渐()。",[48,50,52],{"key":20,"text":49,"correct":26},".增大",{"key":24,"text":51,"correct":26},".不变",{"key":28,"text":53,"correct":22},".衰减",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":28,"analysis":33},716719,"电流保护的动作时间一经整定,则不随通入保护的电流变化,保护起动后按照预先整定值延时动作,称为()。",[58,60,62],{"key":20,"text":59,"correct":26},".零序电流保护",{"key":24,"text":61,"correct":26},".反时限电流保护",{"key":28,"text":63,"correct":22},".定时限过电流保护",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":28,"analysis":33},716720,"继电保护装置中电流继电器接在()的二次测。",[68,70,72],{"key":20,"text":69,"correct":26},".断路器",{"key":24,"text":71,"correct":26},".电压互感器",{"key":28,"text":73,"correct":22},".电流互感器",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":28,"analysis":33},716721,"自动低频减载装置的作用为保证电力系统安全稳定运行及()。",[78,80,82],{"key":20,"text":79,"correct":26},".保证继电保护动作的选择性",{"key":24,"text":81,"correct":26},".保证所有负荷正常运行",{"key":28,"text":83,"correct":22},".保证重要负荷用电",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":31,"analysis":33},716722,"定时限过电流保护的保护范围为()。",[88,90,92,94],{"key":20,"text":89,"correct":26},".本线路全长",{"key":24,"text":91,"correct":26},".本线路全长及下级线路一部分",{"key":28,"text":93,"correct":26},".本线路一部分",{"key":31,"text":95,"correct":22},".本线路及下级线路全长",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":31,"analysis":33},716723,"变压器过电流保护的电流元件的动作电流按躲过变压器可能出现的()整定。",[100,102,104,106],{"key":20,"text":101,"correct":26},".最大三相短路电流",{"key":24,"text":103,"correct":26},".最小两相短路电流",{"key":28,"text":105,"correct":26},".励磁涌流",{"key":31,"text":107,"correct":22},".最大负荷电流",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":24,"analysis":33},716724,"某10kV系统通过配电线路向负荷供电,电源电抗X=0.12Ω,线路长度=10km,线路单位长度电抗X=0.30Ω\u002Fkm,当线路末端发生三相短路时,短路电流周期分量为()。",[112,114,116,118],{"key":20,"text":113,"correct":26},".3.50k",{"key":24,"text":115,"correct":22},".1.85k",{"key":28,"text":117,"correct":26},".2.17k",{"key":31,"text":119,"correct":26},".3.07k",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":20,"analysis":33},716725,"某变电站采用备用电源自动投入装置,当工作电源故障时,自投装置自动投入,但故障没有消除,据分析此时()。",[124,126,128,130],{"key":20,"text":125,"correct":22},".保护将动作跳闸,自投装置不再投入",{"key":24,"text":127,"correct":26},".自投装置将再次投入,如跳闸后不再投",{"key":28,"text":129,"correct":26},".自投装置将再次投入,直到成功",{"key":31,"text":131,"correct":26},".自投装置将再次投入,故障后发信号",{"id":133,"libraryId":5,"type":15,"typeLabel":16,"stem":134,"options":135,"answer":24,"analysis":33},716726,"瞬时电流速断保护的()用最小保护范围衡量。",[136,138,140],{"key":20,"text":137,"correct":26},".快速性",{"key":24,"text":139,"correct":22},".灵敏度",{"key":28,"text":141,"correct":26},".选择性",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":28,"analysis":33},716727,"低压配电网中保护中性线代号为()。",[146,148,150],{"key":20,"text":147,"correct":26},"N",{"key":24,"text":149,"correct":26},"PE",{"key":28,"text":151,"correct":22},"PEN",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":28,"analysis":33},716728,"电力系统正常运行时仅有()。",[156,158,160],{"key":20,"text":157,"correct":26},".零序分量",{"key":24,"text":159,"correct":26},".负序分量",{"key":28,"text":161,"correct":22},".正序分量",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":20,"analysis":33},716729,"电压继电器在继电保护装置中反应()变化而动作。",[166,168,170],{"key":20,"text":167,"correct":22},".电压",{"key":24,"text":169,"correct":26},".电流",{"key":28,"text":171,"correct":26},".功率",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":28,"analysis":33},716730,"高压电动机通常装设纵差动保护或电流速断保护、负序电流保护、起动时间过长保护、()、堵转保护、过电流保护、单相接地保护、低电压保护等。",[176,178,180],{"key":20,"text":177,"correct":26},".气体保护",{"key":24,"text":179,"correct":26},".距离保护",{"key":28,"text":181,"correct":22},".过热保护",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":24,"analysis":33},716731,"电流互感器一次绕组和二次绕组的极性通常采用()标注。",[186,188,190],{"key":20,"text":187,"correct":26},".加极性原则",{"key":24,"text":189,"correct":22},".减极性原则",{"key":28,"text":191,"correct":26},".同极性原则",{"id":193,"libraryId":5,"type":15,"typeLabel":16,"stem":194,"options":195,"answer":28,"analysis":33},716732,"在使用跌落式熔断器时,应按照()、额定电流和额定开断电流选择。",[196,198,200,202],{"key":20,"text":197,"correct":26},".额定功率",{"key":24,"text":199,"correct":26},".额定频率",{"key":28,"text":201,"correct":22},".额定电压",{"key":31,"text":203,"correct":26},".额定负荷电流",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":20,"analysis":33},716733,"三段式零序电流保护中第III段为()",[208,210,212],{"key":20,"text":209,"correct":22},".零序过电流保护",{"key":24,"text":211,"correct":26},".限时零序电流速断保护",{"key":28,"text":213,"correct":26},".瞬时零序电流速断保护",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":33},716734,"以下保护中()可以快速切除全线的短路故障。",[218,220,221,223],{"key":20,"text":219,"correct":26},".瞬时电流速断保护",{"key":24,"text":213,"correct":26},{"key":28,"text":222,"correct":22},".线路纵差保护",{"key":31,"text":224,"correct":26},".距离保护I段",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":20,"analysis":33},716735,"将非正常操作断开的断路器按需要自动重新合闸的一种自动装置称为()。",[229,231,233],{"key":20,"text":230,"correct":22},".自动重合闸装置",{"key":24,"text":232,"correct":26},".低压减载装置",{"key":28,"text":234,"correct":26},".备用电源自动投入装置",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":28,"analysis":33},716736,"零序电流通过变压器的()和接地故障点形成短路回路。",[239,241,243,245],{"key":20,"text":240,"correct":26},".A相",{"key":24,"text":242,"correct":26},".B相",{"key":28,"text":244,"correct":22},"C相",{"key":31,"text":246,"correct":26},".接地中性点",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":24,"analysis":33},716737,"电动机纵差动保护接线,一侧电流互感器接于机端,另一侧接于()。",[251,253,255],{"key":20,"text":252,"correct":26},".电动机绕组上",{"key":24,"text":254,"correct":22},".中性点侧对应各相上",{"key":28,"text":256,"correct":26},".进线电源线路上",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":20,"analysis":33},716738,"零序电流的大小与接地故障位置有关,接地故障点位于保护安装地点()位置,零序电流数值较大。",[261,263,265],{"key":20,"text":262,"correct":22},".附近",{"key":24,"text":264,"correct":26},".中间",{"key":28,"text":266,"correct":26},".远离",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":24,"analysis":33},716739,"电动机装设过电压保护,当三个相间电压均高于整定值时,保护()。",[271,273,275],{"key":20,"text":272,"correct":26},".发出异常信号",{"key":24,"text":274,"correct":22},".经延时跳闸",{"key":28,"text":276,"correct":26},".不应动作",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":20,"analysis":33},716740,"从屏背面看,屏内安装设备接线所需的各类端子排列,表明屏内设备连接与屏顶设备、屏外设备连接关系的图纸为()。",[281,283,285,287],{"key":20,"text":282,"correct":22},".端子排图",{"key":24,"text":284,"correct":26},".屏背面接线图",{"key":28,"text":286,"correct":26},".原理接线图",{"key":31,"text":288,"correct":26},".屏面布置图",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":31,"analysis":33},716741,"变压器油箱内故障包括绕组与铁芯之间的单相接地故障、一相绕组匝间短路及()等。",[293,295,297,299],{"key":20,"text":294,"correct":26},".引出线上的相间故障",{"key":24,"text":296,"correct":26},".套管破碎通过外壳发生的单相接地故障",{"key":28,"text":298,"correct":26},".引出线的套管闪络故障",{"key":31,"text":300,"correct":22},".绕组间的相间故障",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":20,"analysis":33},716742,"变压器差动保护从原理上能够保证选择性,动作时间整定为()。",[305,307,309,311],{"key":20,"text":306,"correct":22},".0S",{"key":24,"text":308,"correct":26},".0.5S",{"key":28,"text":310,"correct":26},".1S",{"key":31,"text":312,"correct":26},".1.5S",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":24,"analysis":33},716743,"高压电动机通常装设纵差动保护或电流速断保护、负序电流保护、起动时间过长保护、过热保护、堵转保护、过电流保护、单相接地保护、()等。",[317,318,320],{"key":20,"text":179,"correct":26},{"key":24,"text":319,"correct":22},".低电压保护",{"key":28,"text":177,"correct":26},{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":31,"analysis":33},716744,"在微机变压器差动保护中,由于电流互感器变比标准化造成的不平衡电流采取()的措施。",[325,327,329,331],{"key":20,"text":326,"correct":26},".调整电压互感器的变比",{"key":24,"text":328,"correct":26},".电压平衡调整",{"key":28,"text":330,"correct":26},".调整电流互感器的变比",{"key":31,"text":332,"correct":22},".电流平衡调整",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":20,"analysis":33},716745,"正常运行时变压器差动保护中,流入差回路的电流为变压器两侧电流的()。",[337,339,341],{"key":20,"text":338,"correct":22},".相量差",{"key":24,"text":340,"correct":26},".功率差",{"key":28,"text":342,"correct":26},".相角差",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":24,"analysis":33},716746,"继电保护装置中电流继电器接在电流互感器的()。",[347,349,351],{"key":20,"text":348,"correct":26},".一次侧",{"key":24,"text":350,"correct":22},".二次测",{"key":28,"text":352,"correct":26},".一次侧和二次侧均可",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":28,"analysis":33},716747,"隔离开关控制方式中,电压等级为()的隔离开关采用就地控制。",[357,359,361,363],{"key":20,"text":358,"correct":26},".10kV及以下",{"key":24,"text":360,"correct":26},".35kV及以下",{"key":28,"text":362,"correct":22},".110kV及以下",{"key":31,"text":364,"correct":26},".220kV及以下",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":20,"analysis":33},716748,"电动机的过负荷保护采用定时限特性时,保护动作时限应大于电动机的起动时间,一般取()。",[369,371,373,374],{"key":20,"text":370,"correct":22},".9-16S",{"key":24,"text":372,"correct":26},".1-5S",{"key":28,"text":306,"correct":26},{"key":31,"text":375,"correct":26},".20S",{"id":377,"libraryId":5,"type":15,"typeLabel":16,"stem":378,"options":379,"answer":20,"analysis":33},716749,"跌落式熔断器熔丝组件安装在熔丝管内,正常时依靠作用在()上的拉力使熔丝管保持在合闸位置。",[380,382,384,386],{"key":20,"text":381,"correct":22},".熔体",{"key":24,"text":383,"correct":26},".弹簧",{"key":28,"text":385,"correct":26},".熔断器",{"key":31,"text":387,"correct":26},".螺母",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":28,"analysis":33},716750,"某电力公司管辖的辐射性电网,某线路的限时电流速断保护与下级线路瞬时电流速断保护范围重叠,则在重叠区发生故障时()。",[392,394,396,398],{"key":20,"text":393,"correct":26},".仅本线路的限时电流速断保护启动",{"key":24,"text":395,"correct":26},".仅下级线路瞬时电流速断保护启动",{"key":28,"text":397,"correct":22},".保护均启动",{"key":31,"text":399,"correct":26},".保护均不启动",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":31,"analysis":33},716751,"采用二次谐波制动原理构成的变压器差动保护由差动元件、二次谐波制动、()及TA断线检测等部分构成。",[404,406,408,410],{"key":20,"text":405,"correct":26},".延时元件",{"key":24,"text":407,"correct":26},".电压元件",{"key":28,"text":409,"correct":26},".功率方向元件",{"key":31,"text":411,"correct":22},".差动速断元件",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":24,"analysis":33},716752,"某变电站采用微机保护,现在需将某重合闸保护信号接入,应接入()。",[416,418,420,422],{"key":20,"text":417,"correct":26},".模拟量输入系统",{"key":24,"text":419,"correct":22},".开关量输入输出系统",{"key":28,"text":421,"correct":26},".人机对话系统",{"key":31,"text":423,"correct":26},".通讯系统",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":24,"analysis":33},716753,"微机保护中将模拟量转换为数字量称为()。",[428,430,432,434],{"key":20,"text":429,"correct":26},".模拟滤波器",{"key":24,"text":431,"correct":22},".模数转换",{"key":28,"text":433,"correct":26},".多路转换",{"key":31,"text":435,"correct":26},".逻辑判断",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":24,"analysis":33},716754,"断路器位置信号中,当断路器被自动重合闸动作合闸时()。",[440,442,444],{"key":20,"text":441,"correct":26},".绿灯亮",{"key":24,"text":443,"correct":22},".红灯闪",{"key":28,"text":445,"correct":26},".红灯亮",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":24,"analysis":33},716755,"分立元件构成的继电保护二次接线图,展开式原理图中交流电压回路采用的数字组为()。",[450,452,454],{"key":20,"text":451,"correct":26},".0-199",{"key":24,"text":453,"correct":22},".600-799",{"key":28,"text":455,"correct":26},".200-300",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":28,"analysis":33},716756,"备用电源自动投入装置工作时,备用电源投入到持续性故障,备用电源断路器将()。",[460,462,464,466],{"key":20,"text":461,"correct":26},".保持合闸",{"key":24,"text":463,"correct":26},".断开后,再次投入",{"key":28,"text":465,"correct":22},".加速断开",{"key":31,"text":467,"correct":26},".拒绝跳闸",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":24,"analysis":33},716757,"利用变压器励磁涌流中波形间断、短路电流连续的特征,通常采用()构成变压器差动保护。",[472,474,476,478],{"key":20,"text":473,"correct":26},".二次谐波制动原理",{"key":24,"text":475,"correct":22},".鉴别波形间断原理",{"key":28,"text":477,"correct":26},".带速饱和变流器的差动继电器",{"key":31,"text":479,"correct":26},".波形对称原理",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":20,"analysis":33},716758,"变压器气体保护的主要元件是()。",[484,486,488,490],{"key":20,"text":485,"correct":22},".气体继电器",{"key":24,"text":487,"correct":26},".电压继电器",{"key":28,"text":489,"correct":26},".电流继电器",{"key":31,"text":491,"correct":26},".中间继电器",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":24,"analysis":33},716759,"零序电压通常采用三个单相式电压互感器或()取得。",[496,498,500],{"key":20,"text":497,"correct":26},".三个单相式电流互感器",{"key":24,"text":499,"correct":22},".三相五柱式电压互感器",{"key":28,"text":501,"correct":26},".一个单相式电流互感器",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":31,"analysis":33},716760,"微机保护开关量输入\u002F输出系统由微型机的并行口、()、有触点的中间继电器等组成。",[506,507,509,510],{"key":20,"text":433,"correct":26},{"key":24,"text":508,"correct":26},".采样保持",{"key":28,"text":431,"correct":26},{"key":31,"text":511,"correct":22},".光电隔离器件",{"id":513,"libraryId":5,"type":15,"typeLabel":16,"stem":514,"options":515,"answer":20,"analysis":33},716761,"继电保护在需要动作时不拒动,不需要动作时不误动是指保护具有较好的()。",[516,518,519,520],{"key":20,"text":517,"correct":22},".灵敏性",{"key":24,"text":137,"correct":26},{"key":28,"text":141,"correct":26},{"key":31,"text":521,"correct":26},".可靠性",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":20,"analysis":33},716762,"对中、小容量的变压器,可以装设单独的电流速断保护,与()配合构成变压器的主保护。",[526,527,528,530],{"key":20,"text":177,"correct":22},{"key":24,"text":59,"correct":26},{"key":28,"text":529,"correct":26},".过负荷保护",{"key":31,"text":531,"correct":26},".过电流保护",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":33},716763,"时间继电器的文字符号表示为()。",[536,538,539],{"key":20,"text":537,"correct":22},".KT",{"key":24,"text":39,"correct":26},{"key":28,"text":43,"correct":26},{"id":541,"libraryId":5,"type":15,"typeLabel":16,"stem":542,"options":543,"answer":28,"analysis":33},716764,"电动机的各种非接地的不对称故障包括电动机匝间短路、断相、相序接反以及()等。",[544,546,548],{"key":20,"text":545,"correct":26},".过电流",{"key":24,"text":547,"correct":26},".过负荷",{"key":28,"text":549,"correct":22},".供电电压较大不平衡",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":24,"analysis":33},716765,"微机保护采样时,采样频率fs与采样信号中所含最高频率成分fmax的频率的关系为()。",[554,556,558,560],{"key":20,"text":555,"correct":26},".fs＞f max",{"key":24,"text":557,"correct":22},".fs＞2f max",{"key":28,"text":559,"correct":26},".fs＜f max",{"key":31,"text":561,"correct":26},".fs＜2f max",[563,566,569,571,574,577],{"id":564,"name":565,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":567,"name":568,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":570,"name":568,"category":7,"favorite":8},336,{"id":572,"name":573,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":575,"name":576,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":578,"name":579,"category":7,"favorite":8},353,"(N1)叉车司机"]