[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-7":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":537},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,7,50,1668,[13,31,41,51,61,74,84,94,106,116,126,136,146,158,168,177,189,199,206,216,227,237,246,256,266,275,285,297,307,317,329,339,348,358,368,378,390,400,412,423,432,442,452,462,474,486,497,507,517,527],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},716666,1,"单选题","电动机堵转保护动作后,作用于()。",[19,23,27],{"key":20,"text":21,"correct":22},"A",".跳闸",true,{"key":24,"text":25,"correct":26},"B",".信号",false,{"key":28,"text":29,"correct":26},"C",".闭锁电动机","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":24,"analysis":30},716667,"常用的电压互感器接线方式有星形接线、V-V接线、()等。",[35,37,39],{"key":20,"text":36,"correct":26},".三相电流完全星形接线",{"key":24,"text":38,"correct":22},".开口三角形接线",{"key":28,"text":40,"correct":26},".两相电流不完全星形接线",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":24,"analysis":30},716668,"本线路的限时电流速断保护与本线路瞬时电流速断保护范围有重叠区,当在重叠区发生故障时由()。",[45,47,49],{"key":20,"text":46,"correct":26},".本线路的限时电流速断保护动作跳闸",{"key":24,"text":48,"correct":22},".本线路线路瞬时电流速断保护动作跳闸",{"key":28,"text":50,"correct":26},".均动作跳闸",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":28,"analysis":30},716669,"电动机堵转保护在电动机起动结束后()。",[55,57,59],{"key":20,"text":56,"correct":26},".动作",{"key":24,"text":58,"correct":26},".退出",{"key":28,"text":60,"correct":22},".投入",{"id":62,"libraryId":5,"type":15,"typeLabel":16,"stem":63,"options":64,"answer":28,"analysis":30},716670,"瞬时电流速断保护反应线路故障()时动作,且无动作延时。",[65,67,69,71],{"key":20,"text":66,"correct":26},".电压升高",{"key":24,"text":68,"correct":26},".电流减小",{"key":28,"text":70,"correct":22},".电流增大",{"key":72,"text":73,"correct":26},"D",".功率因数增大",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":24,"analysis":30},716671,"三段式电流保护中定时限过电流保护的特点为()。",[78,80,82],{"key":20,"text":79,"correct":26},".无动作延时,通过动作电流的整定保证选择性,只能保护线路始端一部分",{"key":24,"text":81,"correct":22},".带有较长延时,通过动作电流间的灵敏度配合、动作时限的配合保证选择性,能够保护本线路的全长和相邻线路的全长",{"key":28,"text":83,"correct":26},".带有短延时,通过动作电流的整定和短延时保证选择性,可以保护线路全长",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":24,"analysis":30},716672,"三段式电流保护加装()元件后,即可构成三段式方向电流保护。",[88,90,92],{"key":20,"text":89,"correct":26},".低电压",{"key":24,"text":91,"correct":22},".功率方向",{"key":28,"text":93,"correct":26},".过电流",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":30},716673,"低压配电网中性点接地方式采用()。",[98,100,102,104],{"key":20,"text":99,"correct":26},".经消弧线圈接地",{"key":24,"text":101,"correct":26},".经电抗接地",{"key":28,"text":103,"correct":22},".直接接地",{"key":72,"text":105,"correct":26},".经电阻接地",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":30},716674,"变电站中将交流一次侧高电压转换成二次电压,供给控制、测量、保护等二次设备使用的电气设备是()。",[110,112,114],{"key":20,"text":111,"correct":22},".电压互感器",{"key":24,"text":113,"correct":26},".变压器",{"key":28,"text":115,"correct":26},".电流互感器",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":28,"analysis":30},716675,"电动机负序电流保护,当()时闭锁负序电流保护(I2负序电流,I1正序电流)。",[120,122,124],{"key":20,"text":121,"correct":26},".I1&gt;1.2I2",{"key":24,"text":123,"correct":26},".I2&lt;1.2I1",{"key":28,"text":125,"correct":22},".I2&gt;1.2I1",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":28,"analysis":30},716676,"电流互感器常用的接线方式有()、两相不完全星形接线、两相电流差接线等。",[130,132,134],{"key":20,"text":131,"correct":26},".两相完全星形接线",{"key":24,"text":133,"correct":26},".三相不完全星形接线",{"key":28,"text":135,"correct":22},".三相完全星形接线",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":24,"analysis":30},716677,"瞬时电流速断保护对单侧有电源的辐射性电网,保护范围为()。",[140,142,144],{"key":20,"text":141,"correct":26},".本线路全长",{"key":24,"text":143,"correct":22},".本线路一部分",{"key":28,"text":145,"correct":26},".本线路及下级线路全长",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":20,"analysis":30},716678,"电力系统中变压器通常采用Y,d11接线方式,两侧线电流的相位相差()。",[150,152,154,156],{"key":20,"text":151,"correct":22},".30°",{"key":24,"text":153,"correct":26},".45°",{"key":28,"text":155,"correct":26},".60°",{"key":72,"text":157,"correct":26},".90°",{"id":159,"libraryId":5,"type":15,"typeLabel":16,"stem":160,"options":161,"answer":24,"analysis":30},716679,"微机保护中整定值的输入和修改、对微机主系统的检查等工作通过()实现。",[162,164,166],{"key":20,"text":163,"correct":26},".电压形成",{"key":24,"text":165,"correct":22},".人机接口",{"key":28,"text":167,"correct":26},".软件算法",{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":28,"analysis":30},716680,"电力系统是由()、变电所、送电线路、配电线路、电力用户组成的整体。",[172,174,175],{"key":20,"text":173,"correct":26},".继电保护",{"key":24,"text":113,"correct":26},{"key":28,"text":176,"correct":22},".发电厂",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":24,"analysis":30},716681,"线路上发生故障,继电保护动作使断路器跳闸后使断路器自动合闸的装置称为()。",[181,183,185,187],{"key":20,"text":182,"correct":26},".备用电源自动投入装置",{"key":24,"text":184,"correct":22},".自动重合闸装置",{"key":28,"text":186,"correct":26},".低频减载装置",{"key":72,"text":188,"correct":26},".低压减载装置",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":20,"analysis":30},716682,"对上、下级保护之间进行动作时限配合时,下级保护动作时限应比上级保护动作时限()。",[193,195,197],{"key":20,"text":194,"correct":22},".短",{"key":24,"text":196,"correct":26},".长",{"key":28,"text":198,"correct":26},".相等",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":28,"analysis":30},716683,"规程规定:发电机直配网络中接地电容电流大于5A时,中性点接地方式采用()。",[203,204,205],{"key":20,"text":105,"correct":26},{"key":24,"text":103,"correct":26},{"key":28,"text":99,"correct":22},{"id":207,"libraryId":5,"type":15,"typeLabel":16,"stem":208,"options":209,"answer":24,"analysis":30},716684,"变压器零序过电压保护由()和时间元件构成。",[210,212,214],{"key":20,"text":211,"correct":26},".电流元件",{"key":24,"text":213,"correct":22},".零序电压元件",{"key":28,"text":215,"correct":26},".功率元件",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":28,"analysis":30},716685,"变压器电流速断保护利用()保证保护的选择性。",[220,222,223,225],{"key":20,"text":221,"correct":26},".动作时间",{"key":24,"text":91,"correct":26},{"key":28,"text":224,"correct":22},".动作电流",{"key":72,"text":226,"correct":26},".动作电压",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":20,"analysis":30},716686,"电动机的内部发生两相短路,电动机的负序电流()正序电流。",[231,233,235],{"key":20,"text":232,"correct":22},".小于",{"key":24,"text":234,"correct":26},".大于",{"key":28,"text":236,"correct":26},".等于",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":20,"analysis":30},716687,"能够使电流继电器开始动作的最小电流称为电流继电器的()。",[241,242,244],{"key":20,"text":224,"correct":22},{"key":24,"text":243,"correct":26},".返回电流",{"key":28,"text":245,"correct":26},".感应电流",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":20,"analysis":30},716688,"电动机过热保护由过热告警、()、过热禁止再起动构成。",[250,252,254],{"key":20,"text":251,"correct":22},".过热起动",{"key":24,"text":253,"correct":26},".过热闭锁",{"key":28,"text":255,"correct":26},".过热禁止再起动",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":28,"analysis":30},716689,"微机保护采样频率(),越能真实反应被采样信号。",[260,262,264],{"key":20,"text":261,"correct":26},".失真",{"key":24,"text":263,"correct":26},".越低",{"key":28,"text":265,"correct":22},".越高",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":28,"analysis":30},716690,"电动机的过负荷保护的动作对象可以根据需要设置动作于跳闸或动作于()。",[270,272,274],{"key":20,"text":271,"correct":26},".闭锁保护",{"key":24,"text":273,"correct":26},".开放保护",{"key":28,"text":25,"correct":22},{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":20,"analysis":30},716691,"自动重合闸采用操作系统液压过低闭锁时,如断路器动作后液压过低,自动重合闸将()。",[279,281,283],{"key":20,"text":280,"correct":22},".不应动作",{"key":24,"text":282,"correct":26},".延时合闸",{"key":28,"text":284,"correct":26},".自动合闸",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":28,"analysis":30},716692,"变压器异常运行包括外部短路引起的过电流、油箱漏油等造成油面降低及()等。",[289,291,293,295],{"key":20,"text":290,"correct":26},".引出线的套管闪络故障",{"key":24,"text":292,"correct":26},".一相绕组匝间短路",{"key":28,"text":294,"correct":22},".过负荷",{"key":72,"text":296,"correct":26},".绕组间的相间故障",{"id":298,"libraryId":5,"type":15,"typeLabel":16,"stem":299,"options":300,"answer":24,"analysis":30},716693,"自动重合闸实质上是通过将非正常跳开的断路器试探性合闸,实现线路上发生()故障时自动恢复运行。",[301,303,305],{"key":20,"text":302,"correct":26},".永久性",{"key":24,"text":304,"correct":22},".瞬时性",{"key":28,"text":306,"correct":26},".瞬时性故障转换为永久性",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":28,"analysis":30},716694,"继电保护的灵敏度用()表示。",[311,313,315],{"key":20,"text":312,"correct":26},".保护装置反应的故障参数与保护装置的动作参数之积",{"key":24,"text":314,"correct":26},".保护装置反应的故障参数与保护装置的动作参数之和",{"key":28,"text":316,"correct":22},".保护装置反应的故障参数与保护装置的动作参数之比",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":72,"analysis":30},716695,"断路器控制回路中,操作电源电压为()称为弱电控制。",[321,323,325,327],{"key":20,"text":322,"correct":26},".10kV",{"key":24,"text":324,"correct":26},".110V或220V",{"key":28,"text":326,"correct":26},".380V",{"key":72,"text":328,"correct":22},".48V及以下",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":24,"analysis":30},716696,"安装接线图包括()、屏背面接线图及端子排图。",[333,335,337],{"key":20,"text":334,"correct":26},".原理接线图",{"key":24,"text":336,"correct":22},".屏面布置图",{"key":28,"text":338,"correct":26},".逻辑框图",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":72,"analysis":30},716697,"电力系统中,运行人员依靠()了解电力系统的运行状态,监视电气设备的运行参数。",[343,344,345,346],{"key":20,"text":173,"correct":26},{"key":24,"text":115,"correct":26},{"key":28,"text":111,"correct":26},{"key":72,"text":347,"correct":22},".测量仪表",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":24,"analysis":30},716698,"分立元件构成的继电保护二次接线图,展开式原理图中负电源采用的标号为()。",[352,354,356],{"key":20,"text":353,"correct":26},"101,，201",{"key":24,"text":355,"correct":22},"102，202",{"key":28,"text":357,"correct":26},"400-599",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":30},716699,"下列保护中()用于反应电动机在起动过程中或在运行中发生堵转,保护动作于跳闸。",[362,364,366],{"key":20,"text":363,"correct":26},".低电压保护",{"key":24,"text":365,"correct":22},".堵转保护",{"key":28,"text":367,"correct":26},".过热保护",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":20,"analysis":30},716700,"能够使过电压继电器开始动作的()称为过电压继电器的动作电压。",[372,374,376],{"key":20,"text":373,"correct":22},".最小电压",{"key":24,"text":375,"correct":26},".最大电压",{"key":28,"text":377,"correct":26},".任意电压",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":24,"analysis":30},716701,"相间距离保护反应故障为()。",[382,384,386,388],{"key":20,"text":383,"correct":26},".接地故障",{"key":24,"text":385,"correct":22},".相间故障",{"key":28,"text":387,"correct":26},".一相断线",{"key":72,"text":389,"correct":26},".两相断线",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":30},716702,"安装接线图包括屏面布置图、屏背面接线图及()。",[394,396,398,399],{"key":20,"text":395,"correct":22},".端子排图",{"key":24,"text":397,"correct":26},".流程图",{"key":28,"text":334,"correct":26},{"key":72,"text":338,"correct":26},{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":72,"analysis":30},716703,"断路器位置信号中,当断路器在合闸位置时()。",[404,406,408,410],{"key":20,"text":405,"correct":26},".绿灯亮",{"key":24,"text":407,"correct":26},".黄灯闪",{"key":28,"text":409,"correct":26},".绿灯闪",{"key":72,"text":411,"correct":22},".红灯亮",{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":24,"analysis":30},716704,"变压器低电压起动的过电流保护由电流元件、()和时间元件构成。",[416,418,420,421],{"key":20,"text":417,"correct":26},".零序元件",{"key":24,"text":419,"correct":22},".电压元件",{"key":28,"text":215,"correct":26},{"key":72,"text":422,"correct":26},".负序元件",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":20,"analysis":30},716705,"电动机的接地故障电流,中性点不接地系统比中性点经电阻接地系统要()。",[427,429,431],{"key":20,"text":428,"correct":22},".小",{"key":24,"text":430,"correct":26},".大",{"key":28,"text":198,"correct":26},{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":24,"analysis":30},716706,"某电动机装设低电压保护,运行中电压互感器二次发生断线,运行人员判断:此时当供电电网电压降低时保护将()。",[436,438,440],{"key":20,"text":437,"correct":26},".经延时跳闸",{"key":24,"text":439,"correct":22},".不动作",{"key":28,"text":441,"correct":26},".发出异常信号",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":24,"analysis":30},716707,"在三相四线式380V电源供电的电气设备或者单相设备与三相设备共用的电路,应选择()漏电保护装置",[446,448,450],{"key":20,"text":447,"correct":26},"三相三极式",{"key":24,"text":449,"correct":22},"三相四极式",{"key":28,"text":451,"correct":26},"三相三极和单相二极两种",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":20,"analysis":30},716708,"电力系统中变压器发生故障,故障的性质绝大部分为()。",[456,458,460],{"key":20,"text":457,"correct":22},".永久性故障",{"key":24,"text":459,"correct":26},".瞬时性故障",{"key":28,"text":461,"correct":26},".间歇性故障",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":72,"analysis":30},716709,"自动重合闸装置按照重合闸作用断路器的方式可分为()、单相重合闸和综合重合闸。",[466,468,470,472],{"key":20,"text":467,"correct":26},".一次重合闸",{"key":24,"text":469,"correct":26},".单侧电源重合闸",{"key":28,"text":471,"correct":26},".二次重合闸",{"key":72,"text":473,"correct":22},".三相重合闸",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":20,"analysis":30},716710,"备用电源自动投入装置工作时,备用电源只能投入()。",[478,480,482,484],{"key":20,"text":479,"correct":22},".一次",{"key":24,"text":481,"correct":26},".二次",{"key":28,"text":483,"correct":26},".三次",{"key":72,"text":485,"correct":26},".四次",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":20,"analysis":30},716711,"备用电源自动投入装置工作时,当电压互感器二次断线时,自投装置应()。",[490,491,493,495],{"key":20,"text":439,"correct":22},{"key":24,"text":492,"correct":26},".加速动作",{"key":28,"text":494,"correct":26},".延时动作",{"key":72,"text":496,"correct":26},".可靠动作",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":28,"analysis":30},716712,"电动机的接地故障电流大小取决于供电系统的()。",[501,503,505],{"key":20,"text":502,"correct":26},".保护类型",{"key":24,"text":504,"correct":26},".频率大小",{"key":28,"text":506,"correct":22},".接地方式",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":24,"analysis":30},716713,"一般把继电保护动作值、动作时间的计算和()称为继电保护的整定计算。",[511,513,515],{"key":20,"text":512,"correct":26},".继电器选择",{"key":24,"text":514,"correct":22},".灵敏度的校验",{"key":28,"text":516,"correct":26},".相位计算",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":24,"analysis":30},716714,"电流保护的动作时间与通入保护的电流有关,保护起动后,如电流大时动作时间短,电流小时动作时间长称为()。",[521,523,525],{"key":20,"text":522,"correct":26},".定时限过电流保护",{"key":24,"text":524,"correct":22},".反时限电流保护",{"key":28,"text":526,"correct":26},".零序电流保护",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":20,"analysis":30},716715,"作为电气工作者,员工必须熟知本工种的()和施工现场的安全生产制度,不违章作业。",[531,533,535],{"key":20,"text":532,"correct":22},"安全操作规程",{"key":24,"text":534,"correct":26},"生产安排",{"key":28,"text":536,"correct":26},"工作时间",[538,541,544,546,549,552],{"id":539,"name":540,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":542,"name":543,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":545,"name":543,"category":7,"favorite":8},336,{"id":547,"name":548,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":550,"name":551,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":553,"name":554,"category":7,"favorite":8},353,"(N1)叉车司机"]