[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-6":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":556},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,6,50,1668,[13,31,41,51,64,76,86,96,108,120,130,140,152,162,170,180,190,201,211,223,235,244,256,268,278,288,300,312,322,334,344,356,368,380,390,398,406,418,430,440,450,460,472,482,492,504,514,524,536,546],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":30},716616,1,"单选题","电动机负序电流保护动作于()。",[19,23,26],{"key":20,"text":21,"correct":22},"A",".减负荷",false,{"key":24,"text":25,"correct":22},"B",".信号",{"key":27,"text":28,"correct":29},"C",".跳闸",true,"",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":27,"analysis":30},716617,"当电气装置或设备发生火灾或引燃附近可燃物时,首先要()。",[35,37,39],{"key":20,"text":36,"correct":22},"、迅速灭火",{"key":24,"text":38,"correct":22},"、拉开开关",{"key":27,"text":40,"correct":29},"、切断电源",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":27,"analysis":30},716618,"电动机负序电流保护动作时限特性,可以根据需要选择反时限特性或()。",[45,47,49],{"key":20,"text":46,"correct":22},".长延时特性",{"key":24,"text":48,"correct":22},".短延时特性",{"key":27,"text":50,"correct":29},".定时限特性",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":24,"analysis":30},716619,"变压器主保护包括气体保护、纵差动保护或()等。",[55,57,59,61],{"key":20,"text":56,"correct":22},".过负荷保护",{"key":24,"text":58,"correct":29},".电流速断保护",{"key":27,"text":60,"correct":22},".过电流保护",{"key":62,"text":63,"correct":22},"D",".零序保护",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":20,"analysis":30},716620,"电压-无功综合控制的目的是保证系统安全运行、提高()。",[68,70,72,74],{"key":20,"text":69,"correct":29},".供电电压质量",{"key":24,"text":71,"correct":22},".系统频率",{"key":27,"text":73,"correct":22},".系统功率因数",{"key":62,"text":75,"correct":22},".供电可靠性",{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":20,"analysis":30},716621,"变压器电流速断保护装在变压器的(),动作时跳开变压器两侧断路器。",[80,82,84],{"key":20,"text":81,"correct":29},".电源侧",{"key":24,"text":83,"correct":22},".负荷侧",{"key":27,"text":85,"correct":22},".电源侧及负荷侧",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":20,"analysis":30},716622,"电流互感器常用的接线方式有三相完全星形接线、()、两相电流差接线等。",[90,92,94],{"key":20,"text":91,"correct":29},".两相不完全星形接线",{"key":24,"text":93,"correct":22},".三相不完全星形接线",{"key":27,"text":95,"correct":22},".两相完全星形接线",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":24,"analysis":30},716623,"变压器瓦斯保护接线中切换片XB切换到跳闸位置,在变压器内部发生严重故障瓦斯保护动作时()。",[100,102,104,106],{"key":20,"text":101,"correct":22},".只将高压侧断路器切除",{"key":24,"text":103,"correct":29},".断开变压器各侧断路器",{"key":27,"text":105,"correct":22},".只发信号,不跳闸",{"key":62,"text":107,"correct":22},".只将低压侧断路器切除",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":62,"analysis":30},716624,"变电站的主要调压手段是()和控制无功功率补偿电容器。",[112,114,116,118],{"key":20,"text":113,"correct":22},".低频减负荷",{"key":24,"text":115,"correct":22},".采用自动重合闸装置",{"key":27,"text":117,"correct":22},".采用备用电源自投装置",{"key":62,"text":119,"correct":29},".调节有载调压变压器分接头位置",{"id":121,"libraryId":5,"type":15,"typeLabel":16,"stem":122,"options":123,"answer":27,"analysis":30},716625,"为保证电流互感器的综合误差满足小于10%的要求,电流互感器接入的二次负载阻抗要()限制值。",[124,126,128],{"key":20,"text":125,"correct":22},".大于",{"key":24,"text":127,"correct":22},".等于",{"key":27,"text":129,"correct":29},".小于",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":30},716626,"对线路装设的三段电流保护,定时限过电流保护为()的远后备保护。",[134,136,138],{"key":20,"text":135,"correct":29},".相邻线路",{"key":24,"text":137,"correct":22},".本线路",{"key":27,"text":139,"correct":22},".本线路及相邻线路",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":27,"analysis":30},716627,"变压器过电流保护装设在变压器电源侧,由()和时间元件构成。",[144,146,148,150],{"key":20,"text":145,"correct":22},".功率元件",{"key":24,"text":147,"correct":22},".电压元件",{"key":27,"text":149,"correct":29},".电流元件",{"key":62,"text":151,"correct":22},".负序元件",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":20,"analysis":30},716628,"限时电流速断保护的保护范围为线路全长,灵敏度校验应考虑全线路范围内对()的反应能力。",[156,158,160],{"key":20,"text":157,"correct":29},".各种故障",{"key":24,"text":159,"correct":22},".两相短路",{"key":27,"text":161,"correct":22},".三相短路",{"id":163,"libraryId":5,"type":15,"typeLabel":16,"stem":164,"options":165,"answer":20,"analysis":30},716629,"限时电流速断保护灵敏度校验条件为以本线路末端()时,流过保护的最小短路电流进行校验。",[166,167,168],{"key":20,"text":159,"correct":29},{"key":24,"text":161,"correct":22},{"key":27,"text":169,"correct":22},".单相接地短路",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":24,"analysis":30},716630,"二次系统中,由各种电气测量仪表、监测装置、切换开关及其回路接线构成,实现指示或记录一次系统和设备的运行状态和参数的系统称为()。",[174,176,178],{"key":20,"text":175,"correct":22},".继电保护及自动装置系统",{"key":24,"text":177,"correct":29},".测量及监测系统",{"key":27,"text":179,"correct":22},".操作电源系统",{"id":181,"libraryId":5,"type":15,"typeLabel":16,"stem":182,"options":183,"answer":20,"analysis":30},716631,"()是电力系统运行的一个重要指标,反应电力系统有功功率供需平衡的状态。",[184,186,188],{"key":20,"text":185,"correct":29},".频率",{"key":24,"text":187,"correct":22},".电流",{"key":27,"text":189,"correct":22},".电压",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":30},716632,"变压器差动保护的差动元件通常采用比率制动特性,引入外部()作为制动量。",[194,196,198,199],{"key":20,"text":195,"correct":29},".短路电流",{"key":24,"text":197,"correct":22},".功率",{"key":27,"text":189,"correct":22},{"key":62,"text":200,"correct":22},".阻抗",{"id":202,"libraryId":5,"type":15,"typeLabel":16,"stem":203,"options":204,"answer":20,"analysis":30},716633,"规程规定,瞬时电流速断保护的最小保护范围不小于本线路全长的()。",[205,207,209],{"key":20,"text":206,"correct":29},".15%-20%",{"key":24,"text":208,"correct":22},".1%-5%",{"key":27,"text":210,"correct":22},".25%-30%",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":27,"analysis":30},716634,"高压电动机发生匝间短路时,电流增大程度与()有关。",[215,217,219,221],{"key":20,"text":216,"correct":22},".故障位置",{"key":24,"text":218,"correct":22},".电动机型号",{"key":27,"text":220,"correct":29},".短路匝数",{"key":62,"text":222,"correct":22},".故障相别",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":20,"analysis":30},716635,"实际电流互感器在电流变换过程中存在误差,一次电流与二次电流相位并不相等,称为()。",[227,229,231,233],{"key":20,"text":228,"correct":29},".相角误差",{"key":24,"text":230,"correct":22},".变比误差",{"key":27,"text":232,"correct":22},".相对误差",{"key":62,"text":234,"correct":22},".绝对误差",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":20,"analysis":30},716636,"高压电动机通常装设纵差动保护或()、负序电流保护、起动时间过长保护、过热保护、堵转保护、过电流保护、单相接地保护、低电压保护等。",[239,240,242],{"key":20,"text":58,"correct":29},{"key":24,"text":241,"correct":22},".瓦斯保护",{"key":27,"text":243,"correct":22},".距离保护",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":24,"analysis":30},716637,"断路器控制方式中,一对一控制指的是()。",[248,250,252,254],{"key":20,"text":249,"correct":22},".一个控制开关控制一台隔离开关",{"key":24,"text":251,"correct":29},".一个控制开关控制一台断路器",{"key":27,"text":253,"correct":22},".一个控制开关控制多台断路器",{"key":62,"text":255,"correct":22},".一个控制开关控制多台隔离开关",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":20,"analysis":30},716638,"电压互感器接线方式中可用来测量零序电压的接线方式为()。",[260,262,264,266],{"key":20,"text":261,"correct":29},".开口三角形接线",{"key":24,"text":263,"correct":22},".星形接线",{"key":27,"text":265,"correct":22},".两相电流差接线",{"key":62,"text":267,"correct":22},".V-V接线",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":24,"analysis":30},716639,"分立元件构成的继电保护二次接线图,按照其用途可分为原理接线图和()。",[272,274,276],{"key":20,"text":273,"correct":22},".展开图",{"key":24,"text":275,"correct":29},".安装接线图",{"key":27,"text":277,"correct":22},".逻辑框图",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":24,"analysis":30},716640,"当继电保护或断路器拒动时,后备保护切除故障时保证停电范围尽可能小是指保护具有较好的()。",[282,284,286],{"key":20,"text":283,"correct":22},".可靠性",{"key":24,"text":285,"correct":29},".选择性",{"key":27,"text":287,"correct":22},".快速性",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":27,"analysis":30},716641,"跌落式熔断器在短路电流通过时熔丝熔断,熔丝管在(C)作用下跌落,断开一次系统。",[292,294,296,298],{"key":20,"text":293,"correct":22},".熔断器",{"key":24,"text":295,"correct":22},".弹簧",{"key":27,"text":297,"correct":29},".重力",{"key":62,"text":299,"correct":22},".螺母",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":20,"analysis":30},716642,"接地距离保护反应故障为()。",[304,306,308,310],{"key":20,"text":305,"correct":29},".接地故障",{"key":24,"text":307,"correct":22},".相间故障",{"key":27,"text":309,"correct":22},".一相断线",{"key":62,"text":311,"correct":22},".两相断线",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":27,"analysis":30},716643,"电压互感器一次侧接(),二次侧接负载。",[316,318,320],{"key":20,"text":317,"correct":22},".电压互感器二次侧",{"key":24,"text":319,"correct":22},".继电器线圈",{"key":27,"text":321,"correct":29},".系统一次母线",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":62,"analysis":30},716644,"集中采集信息、集中运算处理,微机继电保护与微机监控集成一体,实现对整个变电站设备的保护和监控的方式称为()变电站自动化系统。",[326,328,330,332],{"key":20,"text":327,"correct":22},".主从式",{"key":24,"text":329,"correct":22},".分散式",{"key":27,"text":331,"correct":22},".分布式",{"key":62,"text":333,"correct":29},".集中式",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":24,"analysis":30},716645,"低电压继电器的()之比称为低电压继电器的返回系数。",[338,340,342],{"key":20,"text":339,"correct":22},".返回电流与动作电流",{"key":24,"text":341,"correct":29},".返回电压与动作电压",{"key":27,"text":343,"correct":22},".动作电流与返回电流",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":62,"analysis":30},716646,"自动重合闸装置按照重合闸作用断路器的方式可分为三相重合闸、()和综合重合闸。",[348,350,352,354],{"key":20,"text":349,"correct":22},".单侧电源重合闸",{"key":24,"text":351,"correct":22},".一次重合闸",{"key":27,"text":353,"correct":22},".二次重合闸",{"key":62,"text":355,"correct":29},".单相重合闸",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":24,"analysis":30},716647,"电力系统中变压器通常采用Y,d11接线方式,为使变压器差动保护回路正常时电流为0,电流互感器采用()和相位补偿接线。",[360,362,364,366],{"key":20,"text":361,"correct":22},".保护接线",{"key":24,"text":363,"correct":29},".幅值调整",{"key":27,"text":365,"correct":22},".谐波制动接线",{"key":62,"text":367,"correct":22},".涌流制动接线",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":27,"analysis":30},716648,"在电力系统中,在发生大的有功功率缺额时采用按频率降低自动减负荷装置,也称为()。",[372,374,376,378],{"key":20,"text":373,"correct":22},".备用电源自投装置",{"key":24,"text":375,"correct":22},".自动重合闸装置",{"key":27,"text":377,"correct":29},".自动低频减载装置",{"key":62,"text":379,"correct":22},".继电保护装置",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":24,"analysis":30},716649,"中性点不接地系统通常采用绝缘监视和()的方式实现单相接地保护。",[384,386,388],{"key":20,"text":385,"correct":22},".零序电流I段保护",{"key":24,"text":387,"correct":29},".零序电流III段保护",{"key":27,"text":389,"correct":22},".零序电流II段保护",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":24,"analysis":30},716650,"高压电动机通常装设纵差动保护或电流速断保护、负序电流保护、起动时间过长保护、过热保护、堵转保护、过电流保护、()、低电压保护等。",[394,395,397],{"key":20,"text":241,"correct":22},{"key":24,"text":396,"correct":29},".单相接地保护",{"key":27,"text":243,"correct":22},{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":24,"analysis":30},716651,"继电保护装置以尽可能快的速度切除故障元件或设备是指保护具有较好的()。",[402,403,404],{"key":20,"text":285,"correct":22},{"key":24,"text":287,"correct":29},{"key":27,"text":405,"correct":22},".灵敏性",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":20,"analysis":30},716652,"某变电站采用变压器备自投接线,工作变压器故障后跳闸,但备用变压器并无电压,据分析此时()。",[410,412,414,416],{"key":20,"text":411,"correct":29},".自投装置不会投入",{"key":24,"text":413,"correct":22},".自投装置投入备用电源",{"key":27,"text":415,"correct":22},".自投装置投入备用电源后再跳开",{"key":62,"text":417,"correct":22},".自投装置将再次投入工作变压器",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":27,"analysis":30},716653,"电力系统继电保护由测量部分、()和执行部分构成。",[422,424,426,428],{"key":20,"text":423,"correct":22},".显示部分",{"key":24,"text":425,"correct":22},".判断部分",{"key":27,"text":427,"correct":29},".逻辑部分",{"key":62,"text":429,"correct":22},".采样部分",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":24,"analysis":30},716654,"中性点不接地系统发生单相接地故障,故障线路零序电流()。",[434,436,438],{"key":20,"text":435,"correct":22},".等于0",{"key":24,"text":437,"correct":29},".等于各非故障线路对地电容电流之和",{"key":27,"text":439,"correct":22},".等于本线路对地电容电流",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":24,"analysis":30},716655,"微机保护数据采集系统包括电压形成、模拟滤波器、采样保持、多路转换、()等功能模块。",[444,446,448],{"key":20,"text":445,"correct":22},".人机接口",{"key":24,"text":447,"correct":29},".模数转换",{"key":27,"text":449,"correct":22},".软件算法",{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":24,"analysis":30},716656,"继电保护装置中电压继电器接在电压互感器的()。",[454,456,458],{"key":20,"text":455,"correct":22},".一次侧",{"key":24,"text":457,"correct":29},".二次测",{"key":27,"text":459,"correct":22},".一次侧和二次侧均可",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":62,"analysis":30},716657,"微机保护采样中断的时间间隔Ts与采样频率fs的关系为()。",[464,466,468,470],{"key":20,"text":465,"correct":22},".fs=3\u002FTs",{"key":24,"text":467,"correct":22},".Ts=2fs",{"key":27,"text":469,"correct":22},".Ts=fs",{"key":62,"text":471,"correct":29},".fs=1\u002FTs",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":27,"analysis":30},716658,"低压配电网中所有设备的外露可导电部分均接公共保护线PE,或接公共保护中性线PEN的系统称为()。",[476,478,480],{"key":20,"text":477,"correct":22},".IT系统",{"key":24,"text":479,"correct":22},".TT系统",{"key":27,"text":481,"correct":29},".TN系统",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":27,"analysis":30},716659,"绝缘监视装置又称为()。",[486,488,490],{"key":20,"text":487,"correct":22},".接地选线装置",{"key":24,"text":489,"correct":22},".负序电压保护",{"key":27,"text":491,"correct":29},".零序电压保护",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":27,"analysis":30},716660,"变压器油箱外故障包括引出线上的相间故障、套管破碎通过外壳发生的单相接地故障及()等。",[496,498,500,502],{"key":20,"text":497,"correct":22},".绕组与铁芯之间的单相接地故障",{"key":24,"text":499,"correct":22},".一相绕组匝间短路",{"key":27,"text":501,"correct":29},".引出线的套管闪络故障",{"key":62,"text":503,"correct":22},".绕组间的相间故障",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":27,"analysis":30},716661,"电动机过热保护采用()模拟电动机的发热效应。",[508,510,512],{"key":20,"text":509,"correct":22},".最大短路电流",{"key":24,"text":511,"correct":22},".最大负荷电流",{"key":27,"text":513,"correct":29},".等效运行电流",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":27,"analysis":30},716662,"电力系统的电压与()密切相关。",[518,520,522],{"key":20,"text":519,"correct":22},".视在功率",{"key":24,"text":521,"correct":22},".有功功率",{"key":27,"text":523,"correct":29},".无功功率",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":27,"analysis":30},716663,"对于容量在()并列运行变压器或企业中的重要变压器应装设纵差动保护。",[528,530,532,534],{"key":20,"text":529,"correct":22},".800kV及以上",{"key":24,"text":531,"correct":22},".2000kV以上",{"key":27,"text":533,"correct":29},".6300kV以上",{"key":62,"text":535,"correct":22},".400kV及以上",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":20,"analysis":30},716664,"对继电保护的基本要求是:()四性。",[540,542,544],{"key":20,"text":541,"correct":29},".可靠性、选择性、灵敏性、快速性",{"key":24,"text":543,"correct":22},".安全性、选择性、灵敏性、可靠性",{"key":27,"text":545,"correct":22},".快速性、选择性、灵敏性、预防性",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":20,"analysis":30},716665,"对单侧有电源的辐射形电网,瞬时电流速断保护对下级线路故障应()。",[550,552,554],{"key":20,"text":551,"correct":29},".不动作",{"key":24,"text":553,"correct":22},".正确动作",{"key":27,"text":555,"correct":22},".不确定",[557,560,563,565,568,571],{"id":558,"name":559,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":561,"name":562,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":564,"name":562,"category":7,"favorite":8},336,{"id":566,"name":567,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":569,"name":570,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":572,"name":573,"category":7,"favorite":8},353,"(N1)叉车司机"]