[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":548},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,5,50,1668,[13,31,41,54,64,74,86,95,105,115,125,135,146,155,167,178,190,200,210,220,230,239,249,259,269,281,291,303,315,327,339,349,359,370,380,388,400,410,422,429,439,451,461,473,485,495,505,514,526,538],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},716566,1,"单选题","零序电压的大小可根据表达式()求得。",[19,23,27],{"key":20,"text":21,"correct":22},"A","30=A+B+C",true,{"key":24,"text":25,"correct":26},"B","30=-(A+B+C）",false,{"key":28,"text":29,"correct":26},"C","30=A+B-C","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":24,"analysis":30},716567,"高压电动机通常装设纵差动保护或电流速断保护、负序电流保护、()、过热保护、堵转保护、过电流保护、单相接地保护、低电压保护等。",[35,37,39],{"key":20,"text":36,"correct":26},".瓦斯保护",{"key":24,"text":38,"correct":22},".起动时间过长保护",{"key":28,"text":40,"correct":26},".距离保护",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":20,"analysis":30},716568,"采用二次谐波制动原理的变压器差动保护,当任一相差动回路电流的二次谐波含量满足制动判据时即闭锁保护称为()。",[45,47,49,51],{"key":20,"text":46,"correct":22},".最大相制动",{"key":24,"text":48,"correct":26},".分相制动",{"key":28,"text":50,"correct":26},".分相差动",{"key":52,"text":53,"correct":26},"D",".三相差动",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":24,"analysis":30},716569,"反应故障时电流增大动作的过电流保护,要使保护动作,灵敏系数必须()。",[58,60,62],{"key":20,"text":59,"correct":26},".小于1",{"key":24,"text":61,"correct":22},".大于1",{"key":28,"text":63,"correct":26},".等于1",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":28,"analysis":30},716570,"电动机在起动过程中或运行中发生堵转,电流将()。",[68,70,72],{"key":20,"text":69,"correct":26},".减小",{"key":24,"text":71,"correct":26},".不变",{"key":28,"text":73,"correct":22},".急剧增大",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":28,"analysis":30},716571,"采用二次谐波制动原理构成的变压器差动保护由差动元件、二次谐波制动、差动速断元件及()等部分构成。",[78,80,82,84],{"key":20,"text":79,"correct":26},".延时元件",{"key":24,"text":81,"correct":26},".功率方向元件",{"key":28,"text":83,"correct":22},".T断线检测",{"key":52,"text":85,"correct":26},".电压元件",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":20,"analysis":30},716572,"电动机在起动过程中发生堵转,由()作用。",[90,91,93],{"key":20,"text":38,"correct":22},{"key":24,"text":92,"correct":26},".堵转保护",{"key":28,"text":94,"correct":26},".过热保护",{"id":96,"libraryId":5,"type":15,"typeLabel":16,"stem":97,"options":98,"answer":24,"analysis":30},716573,"继电保护反映电力系统元件和电气设备的(),根据运行维护条件和设备的承受能力,自动发出信号、减负荷或延时跳闸。",[99,101,103],{"key":20,"text":100,"correct":26},"正常运行状态",{"key":24,"text":102,"correct":22},"异常运行状态",{"key":28,"text":104,"correct":26},"故障",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":20,"analysis":30},716574,"根据对触电事故发生统计分析,触电事故随季节有明显的变化,每年()季较为易发、集中。",[109,111,113],{"key":20,"text":110,"correct":22},"二;三",{"key":24,"text":112,"correct":26},"一;二",{"key":28,"text":114,"correct":26},"三;四",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":20,"analysis":30},716575,"电动机负序电流保护主要针对各种非接地的()故障。",[119,121,123],{"key":20,"text":120,"correct":22},".不对称",{"key":24,"text":122,"correct":26},".对称",{"key":28,"text":124,"correct":26},".三相短路",{"id":126,"libraryId":5,"type":15,"typeLabel":16,"stem":127,"options":128,"answer":20,"analysis":30},716576,"中性点直接接地运行的变压器接地保护通常采用()。",[129,131,133],{"key":20,"text":130,"correct":22},".二段式零序电流保护",{"key":24,"text":132,"correct":26},".一段式零序电流保护",{"key":28,"text":134,"correct":26},".三段式零序电流保护",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":20,"analysis":30},716577,"变压器保护中()、过电流保护为变压器的后备保护。",[139,141,142,144],{"key":20,"text":140,"correct":22},".零序电流保护",{"key":24,"text":36,"correct":26},{"key":28,"text":143,"correct":26},".过负荷保护",{"key":52,"text":145,"correct":26},".速断电流保护",{"id":147,"libraryId":5,"type":15,"typeLabel":16,"stem":148,"options":149,"answer":24,"analysis":30},716578,"继电保护中相间短路通常仅考虑两相短路、()几种情况。",[150,152,153],{"key":20,"text":151,"correct":26},".单相接地短路",{"key":24,"text":124,"correct":22},{"key":28,"text":154,"correct":26},".二相断开",{"id":156,"libraryId":5,"type":15,"typeLabel":16,"stem":157,"options":158,"answer":28,"analysis":30},716579,"变压器瓦斯保护接线中的中间继电器具有()功能,防止动作期间由于气流及油流不稳定造成触点接触不稳定。",[159,161,163,165],{"key":20,"text":160,"correct":26},".重合闸",{"key":24,"text":162,"correct":26},".延时",{"key":28,"text":164,"correct":22},".自保持",{"key":52,"text":166,"correct":26},".备用电源自投",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":24,"analysis":30},716580,"距离保护采用三段式,分为相间距离保护和()。",[171,172,174,176],{"key":20,"text":140,"correct":26},{"key":24,"text":173,"correct":22},".接地距离保护",{"key":28,"text":175,"correct":26},".电流保护",{"key":52,"text":177,"correct":26},".低电压保护",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":24,"analysis":30},716581,"变压器空载投入或外部短路故障切除电压恢复时,励磁电流约为变压器额定电流的()。",[182,184,186,188],{"key":20,"text":183,"correct":26},".3%-5%",{"key":24,"text":185,"correct":22},".6-8倍",{"key":28,"text":187,"correct":26},".3-5倍",{"key":52,"text":189,"correct":26},".10%-15%",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":28,"analysis":30},716582,"三段式电流保护中瞬时电流速断的特点为()。",[194,196,198],{"key":20,"text":195,"correct":26},".带有较长延时,通过动作电流间的灵敏度配合、动作时限的配合保证选择性,能够保护本线路的全长和相邻线路的全长",{"key":24,"text":197,"correct":26},".带有短延时,通过动作电流的整定和短延时保证选择性,可以保护线路全长",{"key":28,"text":199,"correct":22},".无动作延时,通过动作电流的整定保证选择性,只能保护线路始端一部分",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":20,"analysis":30},716583,"电流继电器在继电保护装置中作为测量和起动元件,反应()而动作。",[204,206,208],{"key":20,"text":205,"correct":22},".电流增大超过定值",{"key":24,"text":207,"correct":26},".电流减小超过定值",{"key":28,"text":209,"correct":26},".电压增大超过定值",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":30},716584,"零序电流I段保护与()构成线路接地短路的主保护。",[214,216,218],{"key":20,"text":215,"correct":26},".零序电流III段保护",{"key":24,"text":217,"correct":22},".零序电流II段保护",{"key":28,"text":219,"correct":26},".限时电流速段保护",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":24,"analysis":30},716585,"对中、小容量的变压器,可以装设单独的(),与气体保护配合构成变压器的主保护。",[224,226,228,229],{"key":20,"text":225,"correct":26},".过电流保护",{"key":24,"text":227,"correct":22},".电流速断保护",{"key":28,"text":143,"correct":26},{"key":52,"text":140,"correct":26},{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":20,"analysis":30},716586,"继电保护根据所承担的任务分为主保护和()。",[234,236,238],{"key":20,"text":235,"correct":22},".后备保护",{"key":24,"text":237,"correct":26},".微机保护",{"key":28,"text":175,"correct":26},{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":20,"analysis":30},716587,"对于反应故障参数上升而动作的过量继电保护装置,灵敏度计算为()。",[243,245,247],{"key":20,"text":244,"correct":22},".保护范围末发生金属性短路时故障参数最小计算值除以保护装置的动作参数",{"key":24,"text":246,"correct":26},".保护范围末发生金属性短路时故障参数最大计算值除以保护装置的动作参数",{"key":28,"text":248,"correct":26},".保护装置的动作参数除以保护范围末发生金属性短路时故障参数最小值",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":20,"analysis":30},716588,"零序电流的大小可根据表达式()求得。",[253,255,257],{"key":20,"text":254,"correct":22},"3 0 = A+ B+ C",{"key":24,"text":256,"correct":26},"3 0=－（A+ B+ C）",{"key":28,"text":258,"correct":26},"3 0= A+ B－C",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":24,"analysis":30},716589,"在任何情况下,自动重合闸的动作次数应()。",[263,265,267],{"key":20,"text":264,"correct":26},".自动重合一次",{"key":24,"text":266,"correct":22},".符合预先规定的次数",{"key":28,"text":268,"correct":26},".自动重合二次",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":28,"analysis":30},716590,"变压器差动保护灵敏度校验,规程规定灵敏度系数应()。",[273,275,277,279],{"key":20,"text":274,"correct":26},".＞2",{"key":24,"text":276,"correct":26},".＞4",{"key":28,"text":278,"correct":22},".＜2",{"key":52,"text":280,"correct":26},".＜4",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":24,"analysis":30},716591,"一般把继电保护动作值、()的计算和灵敏度的校验称为继电保护的整定计算。",[285,287,289],{"key":20,"text":286,"correct":26},".功率",{"key":24,"text":288,"correct":22},".动作时间",{"key":28,"text":290,"correct":26},".相位",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":52,"analysis":30},716592,"分立元件构成的继电保护二次接线图,按照其用途可分为()和安装接线图。",[295,297,299,301],{"key":20,"text":296,"correct":26},".正视图",{"key":24,"text":298,"correct":26},".逻辑框图",{"key":28,"text":300,"correct":26},".流程图",{"key":52,"text":302,"correct":22},".原理接线图",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":20,"analysis":30},716593,"变压器油箱内故障包括绕组间的相间短路、绕组与铁芯之间的接地故障及()等。",[307,309,311,313],{"key":20,"text":308,"correct":22},".一相绕组匝间短路",{"key":24,"text":310,"correct":26},".引出线的套管闪络故障",{"key":28,"text":312,"correct":26},".引出线上的相间故障",{"key":52,"text":314,"correct":26},".套管破碎通过外壳发生的单相接地故障",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":20,"analysis":30},716594,"跌落式熔断器的()相当于保护功能的整定值。",[319,321,323,325],{"key":20,"text":320,"correct":22},".下限开断电流",{"key":24,"text":322,"correct":26},".上限开断电流",{"key":28,"text":324,"correct":26},".额定电流",{"key":52,"text":326,"correct":26},".额定负荷电流",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":28,"analysis":30},716595,"跌落式熔断器在短路电流流过后,装有()的管子自由落下,是一种短路和过负荷保护装置。",[331,333,335,337],{"key":20,"text":332,"correct":26},".电流互感器",{"key":24,"text":334,"correct":26},".电压互感器",{"key":28,"text":336,"correct":22},".熔丝",{"key":52,"text":338,"correct":26},".电流继电器",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":24,"analysis":30},716596,"电动机容量在5MW及以上时,纵差动保护采用()接线。",[343,345,347],{"key":20,"text":344,"correct":26},".一相式",{"key":24,"text":346,"correct":22},".三相式",{"key":28,"text":348,"correct":26},".两相式",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":20,"analysis":30},716597,"当通过电流继电器的电流大于动作电流时,继电器动作,动合触点()。",[353,355,357],{"key":20,"text":354,"correct":22},".闭合",{"key":24,"text":356,"correct":26},".断开",{"key":28,"text":358,"correct":26},".任意位置",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":52,"analysis":30},716598,"跌落式熔断器安装有(),允许切断一定大小的负荷电流。",[363,364,366,368],{"key":20,"text":336,"correct":26},{"key":24,"text":365,"correct":26},".弹簧",{"key":28,"text":367,"correct":26},".螺母",{"key":52,"text":369,"correct":22},".消弧栅",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":20,"analysis":30},716599,"三段式电流保护对双侧有电源的线路或环网线路,通过动作电流、动作时限整定,保护的选择性()。",[374,376,378],{"key":20,"text":375,"correct":22},".有时不能保证",{"key":24,"text":377,"correct":26},".完全可以保证",{"key":28,"text":379,"correct":26},".任何时候都不能保证",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":28,"analysis":30},716600,"电动机单相接地故障的自然接地电流(未补偿过的电流)大于5A时需装设()。",[384,385,386],{"key":20,"text":177,"correct":26},{"key":24,"text":92,"correct":26},{"key":28,"text":387,"correct":22},".单相接地保护",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":28,"analysis":30},716601,"采用波形间断原理构成的变压器差动保护,当间断角小于整定值时()。",[392,394,396,398],{"key":20,"text":393,"correct":26},".起动合闸",{"key":24,"text":395,"correct":26},".闭锁保护",{"key":28,"text":397,"correct":22},".开放保护",{"key":52,"text":399,"correct":26},".发动作信号",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":28,"analysis":30},716602,"自动重合闸采用操作系统气压过低闭锁时,如断路器动作后气压过低,自动重合闸将()。",[404,406,408],{"key":20,"text":405,"correct":26},".自动合闸",{"key":24,"text":407,"correct":26},".延时合闸",{"key":28,"text":409,"correct":22},".不应动作",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":28,"analysis":30},716603,"变压器励磁涌流产生的根本原因是()。",[414,416,418,420],{"key":20,"text":415,"correct":26},".变压器的容量大",{"key":24,"text":417,"correct":26},".变压器的电压等级高",{"key":28,"text":419,"correct":22},".变压器铁芯中的磁通不能突变",{"key":52,"text":421,"correct":26},".变压器的接线组别影响",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":24,"analysis":30},716604,"下列保护中()用于运行过程中易发生过负荷的电动机。",[426,427,428],{"key":20,"text":177,"correct":26},{"key":24,"text":143,"correct":22},{"key":28,"text":92,"correct":26},{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":28,"analysis":30},716605,"瞬时电流速断保护对线路的保护,当线路在最大运行方式下发生三相短路时()。",[433,435,437],{"key":20,"text":434,"correct":26},".保护范围无论何时均相同",{"key":24,"text":436,"correct":26},".保护有最小的保护范围",{"key":28,"text":438,"correct":22},".保护有最大的保护范围",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":24,"analysis":30},716606,"跌落式熔断器在短路电流通过时熔丝熔断,熔丝管在重力作用下跌落,断开()。",[443,445,447,449],{"key":20,"text":444,"correct":26},".二次系统",{"key":24,"text":446,"correct":22},".一次系统",{"key":28,"text":448,"correct":26},".合闸回路",{"key":52,"text":450,"correct":26},".跳闸回路",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":28,"analysis":30},716607,"电动机纵差动保护接线采用比率制动特性,应保证躲过电动机全电压起动时、正常运行时以及()差动回路的不平衡电流。",[455,457,459],{"key":20,"text":456,"correct":26},".内部两相短路时",{"key":24,"text":458,"correct":26},".内部接地短路时",{"key":28,"text":460,"correct":22},".外部三相短路电动机向外供给短路电流时",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":52,"analysis":30},716608,"变压器差动保护可实现(),外部故障时不动作,从原理上能够保证选择性。",[465,467,469,471],{"key":20,"text":466,"correct":26},".过电流时延时动作",{"key":24,"text":468,"correct":26},".轻微故障时发信号",{"key":28,"text":470,"correct":26},".过负荷时发信号",{"key":52,"text":472,"correct":22},".内部故障时动作",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":20,"analysis":30},716609,"外部故障时变压器差动保护中,流入差动继电器的电流为()。",[477,479,481,483],{"key":20,"text":478,"correct":22},".不平衡电流",{"key":24,"text":480,"correct":26},".低压侧电流",{"key":28,"text":482,"correct":26},".高压侧电流",{"key":52,"text":484,"correct":26},".故障电流",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":20,"analysis":30},716610,"为保证零序电流III段保护的选择性,各级保护动作电流配合为()。",[489,491,493],{"key":20,"text":490,"correct":22},".本线路III段动作电流大于下级线路III段动作电流",{"key":24,"text":492,"correct":26},".本线路III段动作电流小于下级线路III段动作电流",{"key":28,"text":494,"correct":26},".本线路III段动作电流等于下级线路III段动作电流",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":20,"analysis":30},716611,"按电压降低自动减负荷装置的低电压元件的整定值应()电压崩溃的临界电压,并留有一定的裕度。",[499,501,503],{"key":20,"text":500,"correct":22},".高于",{"key":24,"text":502,"correct":26},".低于",{"key":28,"text":504,"correct":26},".等于",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":24,"analysis":30},716612,"变压器气体保护包括轻瓦斯保护和()。",[509,510,512,513],{"key":20,"text":143,"correct":26},{"key":24,"text":511,"correct":22},".重瓦斯保护",{"key":28,"text":140,"correct":26},{"key":52,"text":145,"correct":26},{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":52,"analysis":30},716613,"微机保护通过A\u002FD获得输入电压、电流的模拟量的过程称为()。",[518,520,522,524],{"key":20,"text":519,"correct":26},".多路转换",{"key":24,"text":521,"correct":26},".光电隔离",{"key":28,"text":523,"correct":26},".人机接口",{"key":52,"text":525,"correct":22},".采样",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":24,"analysis":30},716614,"利用变压器励磁涌流中含有明显的二次谐波分量的特征,通常采用()构成变压器差动保护。",[530,532,534,536],{"key":20,"text":531,"correct":26},".鉴别波形间断原理",{"key":24,"text":533,"correct":22},".带速饱和变流器的差动继电器",{"key":28,"text":535,"correct":26},".二次谐波制动原理",{"key":52,"text":537,"correct":26},".波形对称原理",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":20,"analysis":30},716615,"绝缘监视装置反应中性点不接地系统发生单相接地故障时,系统出现()而动作发出信号。",[542,544,546],{"key":20,"text":543,"correct":22},".零序电压",{"key":24,"text":545,"correct":26},".零序电流",{"key":28,"text":547,"correct":26},".正序电压",[549,552,555,557,560,563],{"id":550,"name":551,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":553,"name":554,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":556,"name":554,"category":7,"favorite":8},336,{"id":558,"name":559,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":561,"name":562,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":564,"name":565,"category":7,"favorite":8},353,"(N1)叉车司机"]