[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-3":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":555},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,3,50,1668,[13,31,41,51,64,74,84,96,108,118,128,138,148,160,172,182,194,204,216,228,240,250,260,272,282,292,304,316,326,336,346,356,368,380,390,400,410,420,430,442,452,462,474,483,495,505,515,525,535,545],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},716466,1,"单选题","高压电动机发生单相接地故障时应()。",[19,23,27],{"key":20,"text":21,"correct":22},"A",".视接地电流大小可切除电动机或发出报警信号",true,{"key":24,"text":25,"correct":26},"B",".无论电流大小马上切除故障电动机",false,{"key":28,"text":29,"correct":26},"C",".无论电流大小只需发出异常信号","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":28,"analysis":30},716467,"变压器在外部短路时差动保护将()。",[35,37,39],{"key":20,"text":36,"correct":26},".正确动作",{"key":24,"text":38,"correct":26},".误动作",{"key":28,"text":40,"correct":22},".不动作",{"id":42,"libraryId":5,"type":15,"typeLabel":16,"stem":43,"options":44,"answer":24,"analysis":30},716468,"电动机堵转保护动作时间按()整定。",[45,47,49],{"key":20,"text":46,"correct":26},".指定时间0.5S",{"key":24,"text":48,"correct":22},".最大允许堵转时间",{"key":28,"text":50,"correct":26},".与电流速断电流保护时间配合",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":62,"analysis":30},716469,"电力系统中采用电流互感器可以(),保证工作人员的安全。",[55,57,59,61],{"key":20,"text":56,"correct":26},".隔离故障点",{"key":24,"text":58,"correct":26},".将一次高压变换为二次低压",{"key":28,"text":60,"correct":26},".实现安全防护",{"key":62,"text":63,"correct":22},"D",".使二次设备与一次高压隔离",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":24,"analysis":30},716470,"电流互感器采用减极性原则标注是指当一次和二次电流同时从互感器的一次绕组和二次绕组的同极性端子流入时,它们在铁芯中产生的磁通方向()。",[68,70,72],{"key":20,"text":69,"correct":26},".与交、直流有关",{"key":24,"text":71,"correct":22},".相同",{"key":28,"text":73,"correct":26},".相反",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":20,"analysis":30},716471,"电流继电器动作后,使继电器返回到原始状态的()称为电流继电器的返回电流。",[78,80,82],{"key":20,"text":79,"correct":22},".最大电流",{"key":24,"text":81,"correct":26},".最小电流",{"key":28,"text":83,"correct":26},".任意电流值",{"id":85,"libraryId":5,"type":15,"typeLabel":16,"stem":86,"options":87,"answer":28,"analysis":30},716472,"变压器备自投接线中,备用变压器采用()方式。",[88,90,92,94],{"key":20,"text":89,"correct":26},".暗备用",{"key":24,"text":91,"correct":26},".线路备用",{"key":28,"text":93,"correct":22},".明备用",{"key":62,"text":95,"correct":26},".母线备用",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":62,"analysis":30},716473,"变电站自动化系统内部的现场级通讯,主要解决()的数据通讯和信息交换。",[100,102,104,106],{"key":20,"text":101,"correct":26},".变电站与变电站之间",{"key":24,"text":103,"correct":26},".调度与变电站之间",{"key":28,"text":105,"correct":26},".上级调度与下级调度之间",{"key":62,"text":107,"correct":22},".监控主机与各子系统及各子系统之间",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":28,"analysis":30},716474,"电流速断保护在电动机起动时()。",[112,114,116],{"key":20,"text":113,"correct":26},".应可靠动作",{"key":24,"text":115,"correct":26},".发异常信号",{"key":28,"text":117,"correct":22},".不应动作",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":30},716475,"电流互感器的接线方式中,只有二相装有电流互感器以及相应的电流元件,只能反应二相电流的接线方式为()。",[122,124,126],{"key":20,"text":123,"correct":26},".三相完全星形接线",{"key":24,"text":125,"correct":22},".两相不完全星形接线",{"key":28,"text":127,"correct":26},".两相电流差接线",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":24,"analysis":30},716476,"电动机的各种非接地的不对称故障包括()、断相、相序接反以及供电电压较大不平衡等。",[132,134,136],{"key":20,"text":133,"correct":26},".过负荷",{"key":24,"text":135,"correct":22},".电动机匝间短路",{"key":28,"text":137,"correct":26},".过电流",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":30},716477,"零序电流的大小不仅与中性点接地的()有关,而且与系统运行方式有关。",[142,144,146],{"key":20,"text":143,"correct":26},".变压器的型号",{"key":24,"text":145,"correct":22},".变压器的多少、分布",{"key":28,"text":147,"correct":26},".变压器的种类",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":62,"analysis":30},716478,"变压器故障分为油箱内故障和()两大类。",[152,154,156,158],{"key":20,"text":153,"correct":26},".匝间短路故障",{"key":24,"text":155,"correct":26},".绕组故障",{"key":28,"text":157,"correct":26},".绝缘故障",{"key":62,"text":159,"correct":22},".油箱外故障",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":28,"analysis":30},716479,"变压器相间短路的后备保护作为变压器差动保护或电流速断保护和()的后备保护。",[164,166,168,170],{"key":20,"text":165,"correct":26},".过电流保护",{"key":24,"text":167,"correct":26},".零序电流保护",{"key":28,"text":169,"correct":22},".气体保护",{"key":62,"text":171,"correct":26},".负序过电流保护",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":28,"analysis":30},716480,"对中性点不接地系统,根据系统发生单相接地故障时的电流大小及方向特征,实现故障检测与选线的装置为()。",[176,178,180],{"key":20,"text":177,"correct":26},".备用电源自投装置",{"key":24,"text":179,"correct":26},".自动重合闸装置",{"key":28,"text":181,"correct":22},".接地选线装置",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":24,"analysis":30},716481,"断路器位置信号中,当断路器在分闸位置时()。",[186,188,190,192],{"key":20,"text":187,"correct":26},".红灯亮",{"key":24,"text":189,"correct":22},".绿灯亮",{"key":28,"text":191,"correct":26},".黄灯亮",{"key":62,"text":193,"correct":26},".红灯闪",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":24,"analysis":30},716482,"定时限过电流保护远后备灵敏系数计算为()。",[198,200,202],{"key":20,"text":199,"correct":26},".最小运行方式本线路末端两相短路电流与动作电流之比",{"key":24,"text":201,"correct":22},".最小运行方式下级线路末端两相短路电流与动作电流之比",{"key":28,"text":203,"correct":26},".最大运行方式本线路末端三相短路电流与动作电流之比",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":62,"analysis":30},716483,"备用电源自动投入装置应保证()断开后,备用电源才能投入。",[208,210,212,214],{"key":20,"text":209,"correct":26},".备用线路",{"key":24,"text":211,"correct":26},".备用变压器",{"key":28,"text":213,"correct":26},".工作变压器",{"key":62,"text":215,"correct":22},".工作电源",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":62,"analysis":30},716484,"继电保护人员要检查微机保护进行电压电流的数据采样环节,他必须了解其应在()中进行。",[220,222,224,226],{"key":20,"text":221,"correct":26},".初始化模块",{"key":24,"text":223,"correct":26},".跳闸逻辑",{"key":28,"text":225,"correct":26},".系统程序",{"key":62,"text":227,"correct":22},".定时中断程序",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":62,"analysis":30},716485,"变压器气体保护的主要元件是气体继电器,安装在()。",[232,234,236,238],{"key":20,"text":233,"correct":26},".变压器油箱内",{"key":24,"text":235,"correct":26},".低压套管上",{"key":28,"text":237,"correct":26},".高压套管上",{"key":62,"text":239,"correct":22},".变压器油箱与油枕之间的的连接管道中",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":24,"analysis":30},716486,"()系统发生接地短路时产生很大的短路电流,要求继电保护必须及时动作切除故障,保证设备和系统的安全。",[244,246,248],{"key":20,"text":245,"correct":26},".中性点不接地",{"key":24,"text":247,"correct":22},".中性点直接接地系统",{"key":28,"text":249,"correct":26},".中心点经消弧线圈接地",{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":20,"analysis":30},716487,"中间继电器在继电保护中主要实现()。",[254,256,258],{"key":20,"text":255,"correct":22},".增加触点数量和触点容量",{"key":24,"text":257,"correct":26},".启动保护",{"key":28,"text":259,"correct":26},".动作延时",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":62,"analysis":30},716488,"断路器控制回路中,操作电源电压为()称为强电控制。",[264,266,268,270],{"key":20,"text":265,"correct":26},".48V及以下",{"key":24,"text":267,"correct":26},".10kV",{"key":28,"text":269,"correct":26},".380V",{"key":62,"text":271,"correct":22},".110V或220V",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":24,"analysis":30},716489,"下列故障中()属于永久性故障。",[276,278,280],{"key":20,"text":277,"correct":26},".线路对树枝放电",{"key":24,"text":279,"correct":22},".变压器相间短路",{"key":28,"text":281,"correct":26},".大风引起短时碰线",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":24,"analysis":30},716490,"我国规定的交流安全电压为()。",[286,288,290],{"key":20,"text":287,"correct":26},"、220V、42V、36V、12V",{"key":24,"text":289,"correct":22},"、42V、36V、12V、6V",{"key":28,"text":291,"correct":26},"、380V、42V、36V、12V",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":62,"analysis":30},716491,"微机保护的特性和功能主要由()决定。",[296,298,300,302],{"key":20,"text":297,"correct":26},".硬件",{"key":24,"text":299,"correct":26},".电流",{"key":28,"text":301,"correct":26},".电压",{"key":62,"text":303,"correct":22},".软件",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":62,"analysis":30},716492,"电压互感器二次必须有一个(),以防止互感器一、二次绕组绝缘击穿时危及设备和人身安全。",[308,310,312,314],{"key":20,"text":309,"correct":26},".继电保护",{"key":24,"text":311,"correct":26},".电流互感器",{"key":28,"text":313,"correct":26},".安全防护罩",{"key":62,"text":315,"correct":22},".保安接地点",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":28,"analysis":30},716493,"在运行中,()和电火花或电弧等都是电气火灾的直接原因。",[320,322,324],{"key":20,"text":321,"correct":26},"、环境温度",{"key":24,"text":323,"correct":26},"、电压高低",{"key":28,"text":325,"correct":22},"、电流的热量",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":24,"analysis":30},716494,"某电力公司管辖的10kV系统采用中性点不接地运行方式,当系统发生单相接地故障,应()。",[330,332,334],{"key":20,"text":331,"correct":26},".立即跳闸进行故障处理",{"key":24,"text":333,"correct":22},".不必立即跳闸,可以连续运行1-2小时,但需查找故障点,防止故障范围扩大",{"key":28,"text":335,"correct":26},".不影响系统运行,不用理会",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":28,"analysis":30},716495,"装设低电压保护的电动机,在供电电压()时退出。",[340,342,344],{"key":20,"text":341,"correct":26},".不变",{"key":24,"text":343,"correct":26},".升高",{"key":28,"text":345,"correct":22},".降低",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":24,"analysis":30},716496,"继电保护一般用于反应()的电流,因此一般不允许继电保护与测量仪表共用同一电流互感器。",[350,352,354],{"key":20,"text":351,"correct":26},".正常状态",{"key":24,"text":353,"correct":22},".故障状态",{"key":28,"text":355,"correct":26},".停电状态",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":62,"analysis":30},716497,"电流互感器二次侧额定电流一般为()。",[360,362,364,366],{"key":20,"text":361,"correct":26},".0.5",{"key":24,"text":363,"correct":26},".10",{"key":28,"text":365,"correct":26},".8",{"key":62,"text":367,"correct":22},".1或5",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":20,"analysis":30},716498,"变压器励磁涌流中含有明显的()分量,使波形偏向时间轴的一侧。",[372,374,376,378],{"key":20,"text":373,"correct":22},".非周期",{"key":24,"text":375,"correct":26},".周期",{"key":28,"text":377,"correct":26},".矩形波",{"key":62,"text":379,"correct":26},".基波",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":24,"analysis":30},716499,"对线路装设的三段电流保护,定时限过电流保护为()的近后备保护。",[384,386,388],{"key":20,"text":385,"correct":26},".相邻线路",{"key":24,"text":387,"correct":22},".本线路",{"key":28,"text":389,"correct":26},".本线路及相邻线路",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":24,"analysis":30},716500,"对于反应故障参数降低而动作的欠量继电保护装置,灵敏度计算为()。",[394,396,398],{"key":20,"text":395,"correct":26},".保护范围末发生金属性短路时故障参数最小计算值除以保护装置的动作参数",{"key":24,"text":397,"correct":22},".保护装置的动作参数除以保护范围末发生金属性短路时故障参数最大计算值",{"key":28,"text":399,"correct":26},".保护范围末发生金属性短路时故障参数最大计算值除以保护装置的动作参数",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":24,"analysis":30},716501,"高压电动机运行常见的异常运行状态有:()、一相熔断器熔断或三相不平衡、堵转、过负荷引起的过电流、供电电压过低或过高。",[404,406,408],{"key":20,"text":405,"correct":26},".一相绕组的匝间短路",{"key":24,"text":407,"correct":22},".起动时间过长",{"key":28,"text":409,"correct":26},".定子绕组的相间短路故障",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":28,"analysis":30},716502,"反应故障时电压降低动作的低电压保护,要使保护动作,灵敏系数必须()。",[414,416,418],{"key":20,"text":415,"correct":26},".等于1",{"key":24,"text":417,"correct":26},".小于1",{"key":28,"text":419,"correct":22},".大于1",{"id":421,"libraryId":5,"type":15,"typeLabel":16,"stem":422,"options":423,"answer":20,"analysis":30},716503,"电压互感器一般二次侧额定相电压为()。",[424,426,427,429],{"key":20,"text":425,"correct":22},".100\u002FV",{"key":24,"text":269,"correct":26},{"key":28,"text":428,"correct":26},".110V",{"key":62,"text":267,"correct":26},{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":62,"analysis":30},716504,"电压互感器同极性端采用L1、L2、K1、K2标识时,以下表述正确的是()。",[434,436,438,440],{"key":20,"text":435,"correct":26},".L1、L2为同极性端",{"key":24,"text":437,"correct":26},".K1、K2为同极性端",{"key":28,"text":439,"correct":26},".L1、K2为同极性端",{"key":62,"text":441,"correct":22},".L2、K2为同极性端",{"id":443,"libraryId":5,"type":15,"typeLabel":16,"stem":444,"options":445,"answer":20,"analysis":30},716505,"电动机采用熔断器-高压接触器控制时,电流速断保护应与()配合。",[446,448,450],{"key":20,"text":447,"correct":22},".熔断器",{"key":24,"text":449,"correct":26},".高压接触器",{"key":28,"text":451,"correct":26},".过负荷保护",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":20,"analysis":30},716506,"微机保护是指将()等作为核心部件构成的继电保护。",[456,458,460],{"key":20,"text":457,"correct":22},".微型机、微控制器",{"key":24,"text":459,"correct":26},".晶体管",{"key":28,"text":461,"correct":26},".继电器",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":28,"analysis":30},716507,"中央事故音响信号利用“不对应”原则起动,即()时启动事故音响。",[466,468,470,472],{"key":20,"text":467,"correct":26},".断路器跳闸,相应的控制开关在“分闸后”位置",{"key":24,"text":469,"correct":26},".断路器合闸,相应的控制开关在“合闸后”位置",{"key":28,"text":471,"correct":22},".断路器跳闸,相应的控制开关在“合闸后”位置",{"key":62,"text":473,"correct":26},".断路器合闸,相应的控制开关在“分闸后”位置",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":28,"analysis":30},716508,"继电保护装置中电压继电器接在()的二次测。",[478,479,481],{"key":20,"text":311,"correct":26},{"key":24,"text":480,"correct":26},".断路器",{"key":28,"text":482,"correct":22},".电压互感器",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":20,"analysis":30},716509,"变压器差动保护中TA断线监测用于()。",[487,489,491,493],{"key":20,"text":488,"correct":22},".电流互感器二次断线时发出信号",{"key":24,"text":490,"correct":26},".电压互感器一次断线时发出信号",{"key":28,"text":492,"correct":26},".电压互感器二次断线时发出信号",{"key":62,"text":494,"correct":26},".电流互感器一次断线时发出信号",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":20,"analysis":30},716510,"线路上发生绝缘子表面闪络等瞬时性故障时,若使断路器重新合闸时将()。",[499,501,503],{"key":20,"text":500,"correct":22},".可以合闸成功",{"key":24,"text":502,"correct":26},".保护动作再次跳闸",{"key":28,"text":504,"correct":26},".合闸后延时跳闸",{"id":506,"libraryId":5,"type":15,"typeLabel":16,"stem":507,"options":508,"answer":20,"analysis":30},716511,"变压器保护中()、零序电流保护为变压器的后备保护。",[509,510,512,513],{"key":20,"text":165,"correct":22},{"key":24,"text":511,"correct":26},".瓦斯保护",{"key":28,"text":451,"correct":26},{"key":62,"text":514,"correct":26},".速断电流保护",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":28,"analysis":30},716512,"变压器低电压起动的过电流保护的电流元件接在变压器()的电流互感器二次侧。",[519,521,523],{"key":20,"text":520,"correct":26},".电源侧或负荷侧",{"key":24,"text":522,"correct":26},".负荷侧",{"key":28,"text":524,"correct":22},".电源侧",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":28,"analysis":30},716513,"电力系统在运行中发生各种类型短路故障时,将伴随着()部分地区电压降低。",[529,531,533],{"key":20,"text":530,"correct":26},".与负荷电流相等的短路电流",{"key":24,"text":532,"correct":26},".比负荷电流减小的短路电流",{"key":28,"text":534,"correct":22},".比负荷电流增大很多的短路电流",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":28,"analysis":30},716514,"考虑上下级定时限过电流保护灵敏度配合时,动作电流应为()。",[539,541,543],{"key":20,"text":540,"correct":26},".上下级整定值相等",{"key":24,"text":542,"correct":26},".下条线路定时限过电流保护整定值较大",{"key":28,"text":544,"correct":22},".本线路定时限过电流保护整定值较大",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":28,"analysis":30},716515,"电动机负序电流保护,当I2&lt;1.2I1时()(I2负序电流,I1正序电流)。",[549,551,553],{"key":20,"text":550,"correct":26},".发出信号",{"key":24,"text":552,"correct":26},".闭锁保护",{"key":28,"text":554,"correct":22},".自动解除闭锁",[556,559,562,564,567,570],{"id":557,"name":558,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":560,"name":561,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":563,"name":561,"category":7,"favorite":8},336,{"id":565,"name":566,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":568,"name":569,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":571,"name":572,"category":7,"favorite":8},353,"(N1)叉车司机"]