[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-28":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,28,50,1668,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},717716,3,"判断题","微机保护每间隔一个采样间隔会产生一个采样脉冲,微型机将转入执行一次跳闸程序。()",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},717717,"中性点直接接地系统发生接地故障,接地故障点的零序电压最高。()",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},717718,"在微机变压器差动保护中,由于电流互感器变比标准化造成的不平衡电流采取电流平衡调整的措施。()",[38,39],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":21,"analysis":27},717719,"瞬时电流速断保护反应线路故障时电流增大动作,且无动作延时。()",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":25,"analysis":27},717720,"瞬时电流速断保护对线路的保护范围的影响与系统的运行方式和短路类型无直接关系。()",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},717721,"从屏背面看,屏内安装设备接线所需的各类端子排列,表明屏内设备连接与屏顶设备、屏外设备连接关系的图纸为端子排图。()",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":21,"analysis":27},717722,"作为一名电气工作人员,对发现任何人员有违反《电业安全工作规程》,应立即制止。",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":21,"analysis":27},717723,"距离保护的测量元件为阻抗测量元件。()",[68,69],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},717724,"电力系统继电保护由测量部分、逻辑部分和执行部分构成。()",[74,75],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},717725,"微机保护中将模拟量转换为数字量称为模数转换。()",[80,81],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},717726,"电动机纵差动保护中还设有差动电流速断保护,动作电流一般可取1-2倍额定电流。()",[86,87],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":21,"analysis":27},717727,"在电力系统中,在发生大的有功功率缺额时采用按频率降低自动减负荷装置,称为自动低频减载装置。()",[92,93],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":25,"analysis":27},717728,"高压电动机通常装设纵差动保护或电流速断保护、瓦斯保护、起动时间过长保护、过热保护、堵转保护、过负荷保护、单相接地保护、低电压保护等。()",[98,99],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":21,"analysis":27},717729,"变压器励磁涌流随时间衰减,衰减速度与变压器的容量有关。",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":25,"analysis":27},717730,"变压器相间短路的后备保护作为变压器差动保护或电流速断保护和零序电流保护的后备保护。()",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},717731,"继电保护与测量仪表反应的电流范围不同,因此通常不允许共用同一电流互感器。()",[116,117],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":21,"analysis":27},717732,"变电站是电力系统中联系发电厂与用户的中间环节,具有汇集电能和分配电能、变换电压和交换功率等功能。()",[122,123],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":25,"analysis":27},717733,"电压-无功综合控制的目的是保证系统安全运行、提高系统功率因数。()",[128,129],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},717734,"备用电源自动投入装置工作时,当备用电源无压时,备自投装置不应动作。()",[134,135],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":21,"analysis":27},717735,"变压器气体保护包括轻瓦斯保护和重瓦斯保护。()",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":25,"analysis":27},717736,"电力系统中母线和变压器发生故障,必须采用重合闸。()",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":25,"analysis":27},717737,"备用电源自动投入的一次接线方案按照备用方式可以分为变压器备用和暗备用方式。()",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":25,"analysis":27},717738,"电流互感器的接线方式中,只有二相装有电流互感器以及相应的电流元件,只能反应二相电流的接线方式为两相电流差接线。()",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":25,"analysis":27},717739,"电动机装设过电压保护,当三个相间电压均高于整定值时,保护发出异常信号。()",[164,165],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},717740,"变压器气体保护的主要元件是气体继电器,又称瓦斯继电器。()",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":21,"analysis":27},717741,"当电气装置或设备发生火灾或引燃附近可燃物时,首先要切断电源。()",[176,177],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":25,"analysis":27},717742,"电动机单相接地故障电流为10A及以上时,保护将动作于信号。()",[182,183],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":25,"analysis":27},717743,"变电站是把各种天然能源转换成电能的工厂。()",[188,189],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":21,"analysis":27},717744,"电气设备发生火灾时,严禁使用能导电的灭火剂进行带电灭火。",[194,195],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},717745,"高压电动机通常装设纵差动保护或电流速断保护、负序电流保护、起动时间过长保护、过热保护、堵转保护、过负荷保护、单相接地保护、低电压保护等。()",[200,201],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":25,"analysis":27},717746,"变压器油箱外故障包括引出线上的相间短路、一相绕组匝间短路及套管破碎通过外壳发生的单相接地故障等。()",[206,207],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":21,"analysis":27},717747,"对于反应故障参数上升而动作的过量继电保护装置,灵敏度计算为保护范围末发生金属性短路时故障参数最小计算值除以保护装置的动作参数。()",[212,213],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},717748,"负荷开关是既能关合、承载、开断运行回路的负荷电流,又能关合、承载、开断短路等异常电流的开关设备。()",[218,219],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":25,"analysis":27},717749,"规程规定,对于容量在400kVA及以上的油浸式变压器,应装设瓦斯保护。()",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":25,"analysis":27},717750,"当电动机供电网络电压降低时,电动机转速会升高。()",[230,231],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":21,"analysis":27},717751,"跌落式熔断器的下限开断电流相当于保护功能的整定值。()",[236,237],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":25,"analysis":27},717752,"中性点不接地系统发生单相接地故障,故障相零序电流方向为由母线流向线路。()",[242,243],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},717753,"变压器差动保护的差动元件通常采用比率制动特性,内部故障时,制动量较小,保护动作。()",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":21,"analysis":27},717754,"微机保护的电源要求多电压等级、且具有良好的抗干扰能力。()",[254,255],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":21,"analysis":27},717755,"定时限过电流保护对负荷存在电动机时应考虑自起动过程中造成的负荷电流增大。()",[260,261],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":21,"analysis":27},717756,"瞬时电流速断保护对线路的保护,当线路在最小运行方式下发生两相短路时保护有最小的保护范围。()",[266,267],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":25,"analysis":27},717757,"定时限过电流保护在本线路和相邻线路保护范围发生短路时只有瞬时电流速断保护拒动才起动。()",[272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":25,"analysis":27},717758,"采用二次谐波制动原理的变压器差动保护,当任一相差动回路电流的二次谐波含量满足制动判据时即闭锁保护称为分相制动。()",[278,279],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":21,"analysis":27},717759,"备用电源自动投入装置工作时,备用电源投入到故障时,继电保护应加速动作。()",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":21,"analysis":27},717760,"电动机过热保护为电动机各种过负荷引起的过热提供保护,也作为电动机短路、起动时间过长、堵转等的后备保护。()",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},717761,"对于接地故障电流不是很大的电动机采用零序电流保护,一般采用零序电流互感器取得零序电流。()",[296,297],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},717762,"本线路的限时电流速断保护与本线路瞬时电流速断保护范围有重叠区,当在重叠区发生故障时由本线路线路瞬时电流速断保护动作跳闸。()",[302,303],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":25,"analysis":27},717763,"变压器主保护包括气体保护、零序保护或电流速断保护等。()",[308,309],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":25,"analysis":27},717764,"变压器发生故障后,应该加强监视,继续维持运行。()",[314,315],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":21,"analysis":27},717765,"针对电力系统可能发生的故障和异常运行状态,需要装设继电保护装置。()",[320,321],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[323,327,330,332,335,338],{"id":324,"name":325,"category":7,"favorite":326},401,"高处安装、维护、拆除",1,{"id":328,"name":329,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":331,"name":329,"category":7,"favorite":8},336,{"id":333,"name":334,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":336,"name":337,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":339,"name":340,"category":7,"favorite":8},353,"(N1)叉车司机"]