[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-22":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,22,50,1668,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},717416,3,"判断题","对中性点不接地系统,发生单相接地故障时故障线路零序电流等于各非故障线路对地电容电流之和,由此可以实现基于零序电流大小选出故障线路。()",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},717417,"变压器差动保护从原理上能够保证选择性,动作时间整定为0.5S。()",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},717418,"零序电流I段保护与零序电流II段保护构成线路接地短路的主保护。()",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},717419,"瞬时电流速断保护的灵敏度用最大保护范围衡量。()",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},717420,"变压器差动保护灵敏度校验,规程规定灵敏度系数应&gt;2。()",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":25,"analysis":27},717421,"电力系统短路中发生三相短路的几率最大。()",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":25,"analysis":27},717422,"中间继电器在继电保护中主要实现动作信号。()",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":21,"analysis":27},717423,"对于反应故障参数降低而动作的欠量继电保护装置,灵敏度计算为保护装置的动作参数除以保护范围末发生金属性短路时故障参数最大计算值。()",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},717424,"线路纵差保护反应被保护线路两端的电流差。()",[74,75],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":25,"analysis":27},717425,"变压器主保护包括过负荷保护、纵差动保护或电流速断保护等。()",[80,81],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},717426,"变压器油箱外故障包括绕组间的线间故障、引出线的套管闪络故障及套管破碎通过外壳发生的单相接地故障等。()",[86,87],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":25,"analysis":27},717427,"自动重合闸装置按照重合闸作用断路器的方式可分为单侧电源重合闸、单相重合闸和综合重合闸。()",[92,93],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":25,"analysis":27},717428,"变压器电流速断保护动作电流按躲过变压器电源侧母线短路时流过保护的最大短路电流,并躲过变压器空载投入时的励磁涌流整定。()",[98,99],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":25,"analysis":27},717429,"电动机的各种非接地的不对称故障包括电动机匝间短路、断相、过电流以及供电电压较大不平衡等。()",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},717430,"变压器过电流保护装设在变压器电源侧,由电流元件和时间元件构成。()",[110,111],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},717431,"定时限过电流保护近后备灵敏度系数要求大于等于1.3-1.5。()",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":21,"analysis":27},717432,"在任何情况下,自动重合闸的动作次数应符合预先规定的次数。()",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":25,"analysis":27},717433,"上下级定时限过电流保护灵敏度配合时,上下级动作电流整定值相等。()",[128,129],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},717434,"从故障切除时间考虑,原则上继电保护动作时间应越短越好。()",[134,135],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":25,"analysis":27},717435,"变压器空载合闸后,产生的励磁涌流随时间逐渐增大。()",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":25,"analysis":27},717436,"电流保护中电流继电器的返回系数一般不小于1。()",[146,147],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":25,"analysis":27},717437,"变压器油箱内故障包括绕组间的线间故障、一相绕组匝间短路及绕组与套管破碎通过外壳发生的单相接地故障等。()",[152,153],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":21,"analysis":27},717438,"备用电源自动投入装置动作时间应考虑故障点有一定的去游离和恢复绝缘时间。()",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},717439,"电力系统短路中单相短路、两相短路为不对称短路。()",[164,165],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":25,"analysis":27},717440,"绝缘监视装置反应中性点不接地系统发生单相接地故障,是由低电压继电器动作后接通信号回路,给出接地故障信号的。()",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":25,"analysis":27},717441,"对于容量在6300kVA以上的单独运行变压器应装设纵差动保护。()",[176,177],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":21,"analysis":27},717442,"根据现场设备的分散地点分别安装现场单元,现场单元可以是微机保护和监控功能二合一的装置,也可以是微机保护和监控部分各自独立的方式称为分散分布式变电站自动化系统。()",[182,183],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":25,"analysis":27},717443,"变压器内部故障时在变压器差动保护中,流入差回路的电流为变压器两侧电流的向量差。()",[188,189],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":21,"analysis":27},717444,"微机型变压器差动保护其幅值调整与相位补偿一般通过软件计算算法实现。()",[194,195],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":25,"analysis":27},717445,"电力系统的电压与有功功率密切相关。()",[200,201],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":21,"analysis":27},717446,"三段式电流保护加装功率方向元件后,即可构成三段式方向电流保护。()",[206,207],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":21,"analysis":27},717447,"纵差动保护可用于电动机的容量小于2MW且电流速断保护不能满足灵敏度要求的电动机。()",[212,213],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},717448,"从屏背面看,表明屏内安装设备背面引出端子之间的连接关系,以及端子排之间的连接关系的图纸为端子排图。()",[218,219],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":25,"analysis":27},717449,"电力系统中变压器通常采用Y,d11接线方式,为使变压器差动保护回路正常时电流为0,电流互感器采用谐波制动接线。()",[224,225],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":25,"analysis":27},717450,"在本线路的限时电流速断保护与下级线路瞬时电流速断保护范围的重叠区发生故障,如瞬时电流速断保护拒动,则上述保护均不动作。()",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":25,"analysis":27},717451,"零序电流I段保护与瞬时电流速段保护构成线路接地短路的主保护。()",[236,237],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":25,"analysis":27},717452,"变压器保护中电流速断保护、零序电流为变压器的后备保护。()",[242,243],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":25,"analysis":27},717453,"限时电流速断保护灵敏度校验条件为以本线路首端两相短路时,流过保护的最小短路电流进行校验。()",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":21,"analysis":27},717454,"自动重合闸的控制开关位置与断路器位置不对应的原理是指控制开关在合闸后位置,断路器实际在断开位置。()",[254,255],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":25,"analysis":27},717455,"电力系统中变压器发生故障,故障的性质绝大部分为瞬时性故障。()",[260,261],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":21,"analysis":27},717456,"近后备保护是在主保护拒动时,由本设备的另一保护实现的后备保护。()",[266,267],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},717457,"断路器控制中,按照操作电源的不同可分为强电控制和弱电控制。()",[272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":25,"analysis":27},717458,"变压器气体保护用于反应变压器油箱内部的各种故障以及过负荷。()",[278,279],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":25,"analysis":27},717459,"变压器瓦斯保护接线中切换片XB有两个位置,即试验位置和信号位置。()",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":21,"analysis":27},717460,"瞬时电流速断保护对线路-变压器接线向负荷供电的情况可以保护线路全长。()",[290,291],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},717461,"电流继电器动作后,使继电器返回到原始状态的最小电流称为电流继电器的返回电流。()",[296,297],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},717462,"中性点经消弧线圈接地的主要目的是减小单相接地故障电流,促进电弧自行熄灭,避免发展成相间短路或烧断导线。()",[302,303],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":25,"analysis":27},717463,"当加于低电压继电器的线圈电压大于继电器的动作电压时,继电器动作。()",[308,309],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":21,"analysis":27},717464,"变压器瓦斯保护接线中的中间继电器具有自保持功能,防止动作期间由于气流及油流不稳定造成触点接触不稳定。()",[314,315],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":21,"analysis":27},717465,"隔离开关是将电气设备与电源进行电气隔离或连接的设备。()",[320,321],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},[323,327,330,332,335,338],{"id":324,"name":325,"category":7,"favorite":326},401,"高处安装、维护、拆除",1,{"id":328,"name":329,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":331,"name":329,"category":7,"favorite":8},336,{"id":333,"name":334,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":336,"name":337,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":339,"name":340,"category":7,"favorite":8},353,"(N1)叉车司机"]