[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-21":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,21,50,1668,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},717366,3,"判断题","高压电动机发生定子绕组的相间短路故障时只要求发出异常信号。()",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":25,"analysis":27},717367,"跌落式熔断器在短路电流流过后,装有电流互感器的管子自由落下,是一种短路和过负荷保护装置。()",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},717368,"电力系统中母线发生故障,故障的性质绝大部分为瞬时性故障。()",[38,39],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":21,"analysis":27},717369,"电力系统中采用电流互感器可以使二次设备与一次高压隔离,保证工作人员的安全。()",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},717370,"电动机采用熔断器-高压接触器控制时,电流速断保护应与熔断器配合。()",[50,51],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},717371,"变压器低电压起动的过电流保护的电压元件动作电压整定,按照躲过正常运行母线可能出现的最低工作电压。()",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":21,"analysis":27},717372,"继电保护二次接线图中,展开式原理接线图简称展开图。()",[62,63],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":25,"analysis":27},717373,"电流互感器一次绕组和二次绕组的极性通常采用加极性原则标注。()",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":25,"analysis":27},717374,"变电站中将交流一次侧大电流转换成二次电流,供给测量、保护等二次设备使用的电气设备是电压互感器。()",[74,75],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},717375,"异常运行情况发生时,瞬时或延时发出警铃音响信号,即预告信号。()",[80,81],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},717376,"变压器纵差动保护或电流速断保护可以反应过负荷以及变压器绕组、套管故障。()",[86,87],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":25,"analysis":27},717377,"电动机的接地故障电流,中性点不接地系统比中性点经高电阻接地系统要大。()",[92,93],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":25,"analysis":27},717378,"微机保护中电流、电压继电器由微型电流、电压继电器实现。()",[98,99],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":21,"analysis":27},717379,"隔离开关操作闭锁的目的是避免带负荷拉合隔离开关。()",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},717380,"按频率降低自动减负荷、按电压降低自动减负荷的目的是保证系统安全运行。()",[110,111],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},717381,"通常继电保护对电流互感器的误差要求其综合误差不超过10%。()",[116,117],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":25,"analysis":27},717382,"电动机的过负荷保护采用定时限特性时,保护动作时限应大于电动机的最大允许堵转时间,一般取16~25S。()",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":21,"analysis":27},717383,"变压器励磁涌流呈非正弦特性,波形不连续,出现间断角。()",[128,129],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},717384,"电流继电器在继电保护装置中作为测量和起动元件,反应电流增大超过定值而动作。()",[134,135],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":21,"analysis":27},717385,"限时电流速断保护动作电流的整定时,可靠系数取1.1-1.2。()",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":25,"analysis":27},717386,"常用的变压器相间短路的后备保护有过电流保护、变压器差动保护、零序电流保护等。()",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":25,"analysis":27},717387,"电力系统出现过负荷、频率降低、过电压等属于故障状态。()",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":21,"analysis":27},717388,"零序电流的大小与接地故障位置有关,接地故障点位于保护安装地点越近,零序电流数值越大。()",[158,159],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},717389,"限时电流速断保护的保护范围为线路全长,灵敏度校验应考虑全线路范围内对各种故障的反应能力。()",[164,165],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},717390,"电流继电器动作后,使继电器返回到原始状态的最大电流称为电流继电器的返回电流。()",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":21,"analysis":27},717391,"中性点采用电阻接地时可以避免中性点接消弧线圈带来的谐振过电压。()",[176,177],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":21,"analysis":27},717392,"继电保护实际动作次数包括保护正确动作次数和误动作次数。()",[182,183],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":21,"analysis":27},717393,"二次系统中,由直流电源和供电网络构成,实现供给二次系统工作电源的系统称为操作电源系统。()",[188,189],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":21,"analysis":27},717394,"低压配电网中中性线的代号为N。()",[194,195],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":21,"analysis":27},717395,"距离保护反应保护安装处至故障点之间的阻抗。()",[200,201],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":25,"analysis":27},717396,"零序电流I段的保护范围为本线路全长。()",[206,207],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":21,"analysis":27},717397,"电力系统中至少有一个中性点直接与接地设施相连接的接地方式称为中性点直接接地。()",[212,213],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":21,"analysis":27},717398,"电力负荷是用户的用电设备或用电单位总体所消耗的功率。()",[218,219],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":25,"analysis":27},717399,"备用电源自动投入装置保证在备用电源故障退出后能够继续获得电源,使变电所的所用电正常供电。()",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":21,"analysis":27},717400,"变压器低电压起动的过电流保护由电流元件、电压元件和时间元件构成。()",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":21,"analysis":27},717401,"跌落式熔断器主要用作配电变压器、电容组、短段电缆线路、架空线路分段或分支线路的短路故障保护。()",[236,237],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":25,"analysis":27},717402,"电力系统短路中三相短路为不对称短路。()",[242,243],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},717403,"线路上发生绝缘子表面闪络等瞬时性故障,当使断路器重新合闸时将可以合闸成功。()",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":21,"analysis":27},717404,"电力系统中变压器通常采用Y,d11接线方式,为使变压器差动保护回路正常时电流为0,变压器Y形侧的三个电流互感器二次绕组采用三角形接线,变比调整为原来的1.732倍（根号3）",[254,255],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":21,"analysis":27},717405,"变压器处于异常运行时应发出信号。()",[260,261],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":21,"analysis":27},717406,"当供电电网电压过高时,会引起电动机铜损和铁损增大,增加电动机温升,电动机应装设过电压保护。()",[266,267],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":25,"analysis":27},717407,"电流继电器在继电保护装置中作为测量和起动元件,反应电流减小超过定值而动作。()",[272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":25,"analysis":27},717408,"二次系统中,由各种电气测量仪表、监测装置、切换开关及其回路接线构成,实现指示或记录一次系统和设备的运行状态和参数的系统称为控制系统。()",[278,279],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":21,"analysis":27},717409,"当本线路限时电流速断保护与下级线路限时电流速断保护配合整定时,具有动作电流降低、灵敏度提高、保护范围增长及动作时间延长的特点。()",[284,285],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":25,"analysis":27},717410,"跌落式熔断器在短路电流流过后,装有熔丝的管子自由落下,是一种零序电流保护装置。()",[290,291],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},717411,"相间距离保护反应故障为接地故障及相间故障。()",[296,297],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},717412,"继电保护二次接线图中,归总式原理接线图简称原理图。()",[302,303],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":21,"analysis":27},717413,"电动机过热保护由过热告警、过热跳闸、过热禁止再起动构成。()",[308,309],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":21,"analysis":27},717414,"自动低频减载装置的作用为保证电力系统安全稳定运行及保证重要负荷用电。()",[314,315],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":21,"analysis":27},717415,"继电保护装置的连接片(或称为压板)用于投入\u002F退出保护,接通\u002F断开保护出口。()",[320,321],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[323,327,330,332,335,338],{"id":324,"name":325,"category":7,"favorite":326},401,"高处安装、维护、拆除",1,{"id":328,"name":329,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":331,"name":329,"category":7,"favorite":8},336,{"id":333,"name":334,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":336,"name":337,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":339,"name":340,"category":7,"favorite":8},353,"(N1)叉车司机"]