[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":557},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,2,50,1668,[13,34,46,58,70,80,90,102,114,124,134,144,156,167,179,189,199,209,221,231,243,253,263,273,285,294,304,314,326,338,348,358,370,380,390,400,410,419,429,439,449,459,471,483,493,503,513,525,535,547],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},716416,1,"单选题","变压器相间短路的后备保护作为()或电流速断保护和气体保护的后备保护。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A",".变压器差动保护",true,{"key":24,"text":25,"correct":26},"B",".过电流保护",false,{"key":28,"text":29,"correct":26},"C",".零序电流保护",{"key":31,"text":32,"correct":26},"D",".负序过电流保护","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},716417,"变压器低电压起动的过电流保护由()、电压元件和时间元件构成。",[38,40,42,44],{"key":20,"text":39,"correct":26},".功率元件",{"key":24,"text":41,"correct":26},".零序元件",{"key":28,"text":43,"correct":22},".电流元件",{"key":31,"text":45,"correct":26},".负序元件",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},716418,"分立元件构成的继电保护二次接线图,展开式原理图中交流电流回路采用的数字组为()。",[50,52,54,56],{"key":20,"text":51,"correct":26},".0-199",{"key":24,"text":53,"correct":22},".400-599",{"key":28,"text":55,"correct":26},".200-300",{"key":31,"text":57,"correct":26},".600-799",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},716419,"自动重合闸装置按照重合闸的动作次数可分为一次重合闸和()。",[62,64,66,68],{"key":20,"text":63,"correct":26},".单相重合闸",{"key":24,"text":65,"correct":26},".三相重合闸",{"key":28,"text":67,"correct":22},".二次(多次)重合闸",{"key":31,"text":69,"correct":26},".综合重合闸",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},716420,"高压电动机发生单相接地故障时,如果接地电流大于(),将造成电动机定子铁芯烧损,并可能发展成匝间短路或相间短路。",[74,76,78],{"key":20,"text":75,"correct":26},".0.5",{"key":24,"text":77,"correct":26},".1",{"key":28,"text":79,"correct":22},".10",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":20,"analysis":33},716421,"变压器差动保护的差动元件通常采用比率制动特性,外部故障时,短路电流增大,制动量()。",[84,86,88],{"key":20,"text":85,"correct":22},".增大",{"key":24,"text":87,"correct":26},".减小",{"key":28,"text":89,"correct":26},".不变",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":28,"analysis":33},716422,"中性点直接接地系统发生接地故障,在三相中将产生()的零序电压。",[94,96,98,100],{"key":20,"text":95,"correct":26},".大小相等、相位相差120度",{"key":24,"text":97,"correct":26},".大小不等、相位相同",{"key":28,"text":99,"correct":22},".大小相等、相位相同",{"key":31,"text":101,"correct":26},".大小不等、相位不同",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":31,"analysis":33},716423,"变压器发生故障后,应该()。",[106,108,110,112],{"key":20,"text":107,"correct":26},".加强监视",{"key":24,"text":109,"correct":26},".继续运行",{"key":28,"text":111,"correct":26},".运行到无法运行时断开",{"key":31,"text":113,"correct":22},".立即将变压器从系统中切除",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":24,"analysis":33},716424,"跌落式熔断器主要用作()、电容组、短段电缆线路、架空线路分段或分支线路的短路故障保护。",[118,120,122],{"key":20,"text":119,"correct":26},".高压输电线路",{"key":24,"text":121,"correct":22},".配电变压器",{"key":28,"text":123,"correct":26},".远距离电缆线路",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":20,"analysis":33},716425,"三段式零序电流保护中第II段为()。",[128,130,132],{"key":20,"text":129,"correct":22},".限时零序电流速断保护",{"key":24,"text":131,"correct":26},".瞬时零序电流速断保护",{"key":28,"text":133,"correct":26},".零序过电流保护",{"id":135,"libraryId":5,"type":15,"typeLabel":16,"stem":136,"options":137,"answer":24,"analysis":33},716426,"电动机负序电流保护,当()时自动解除闭锁(I2负序电流,I1正序电流)。",[138,140,142],{"key":20,"text":139,"correct":26},".I2>1.2I1",{"key":24,"text":141,"correct":22},".I2\u003C1.2I1",{"key":28,"text":143,"correct":26},".I1>1.2I2",{"id":145,"libraryId":5,"type":15,"typeLabel":16,"stem":146,"options":147,"answer":31,"analysis":33},716427,"电力系统中相与相之间或相与地之间,通过电弧或其他较小阻抗形成的一种非正常连接称为()。",[148,150,152,154],{"key":20,"text":149,"correct":26},".开路",{"key":24,"text":151,"correct":26},".虚接",{"key":28,"text":153,"correct":26},".断路",{"key":31,"text":155,"correct":22},".短路",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":31,"analysis":33},716428,"常用的变压器相间短路的后备保护有过电流保护、()、复合电压起动的过电流保护、负序过电流保护、阻抗保护等。",[160,162,164,165],{"key":20,"text":161,"correct":26},".电流速断保护",{"key":24,"text":163,"correct":26},".气体保护",{"key":28,"text":21,"correct":26},{"key":31,"text":166,"correct":22},".低电压起动的过电流保护",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":24,"analysis":33},716429,"利用变压器励磁涌流中含有明显的非周期分量的特征,通常采用()构成变压器差动保护。",[171,173,175,177],{"key":20,"text":172,"correct":26},".鉴别波形间断原理",{"key":24,"text":174,"correct":22},".带速饱和变流器的差动继电器",{"key":28,"text":176,"correct":26},".二次谐波制动原理",{"key":31,"text":178,"correct":26},".波形对称原理",{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":20,"analysis":33},716430,"电力系统中至少有一个中性点直接与接地设施相连接的接地方式称为()。",[183,185,187],{"key":20,"text":184,"correct":22},".中性点直接接地",{"key":24,"text":186,"correct":26},".中性点经电阻接地",{"key":28,"text":188,"correct":26},".中性点经电抗接地",{"id":190,"libraryId":5,"type":15,"typeLabel":16,"stem":191,"options":192,"answer":24,"analysis":33},716431,"低压配电网中所有设备的外露可导电部分均各自经保护线PE单独接地,电源中性点不接地或经电抗接地且通常不引出中性线N的系统称为()。",[193,195,197],{"key":20,"text":194,"correct":26},".TN系统",{"key":24,"text":196,"correct":22},".IT系统",{"key":28,"text":198,"correct":26},".TT系统",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":24,"analysis":33},716432,"电动机的外部发生两相短路,电动机的负序电流()正序电流。",[203,205,207],{"key":20,"text":204,"correct":26},".小于",{"key":24,"text":206,"correct":22},".大于",{"key":28,"text":208,"correct":26},".等于",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":24,"analysis":33},716433,"备用电源自动投入装置应保证工作电源断开后,备用电源才能投入,这样可以防止()。",[213,215,217,219],{"key":20,"text":214,"correct":26},".备用电源电压过低",{"key":24,"text":216,"correct":22},".将备用电源投入到故障上",{"key":28,"text":218,"correct":26},".备用电源不投入",{"key":31,"text":220,"correct":26},".备用电源电压过高",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":28,"analysis":33},716434,"限时电流速断保护灵敏度校验条件为以本线路两相短路时,流过保护的()进行校验。",[225,227,229],{"key":20,"text":226,"correct":26},".任意电流",{"key":24,"text":228,"correct":26},".最大短路电流",{"key":28,"text":230,"correct":22},".最小短路电流",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":20,"analysis":33},716435,"在使用跌落式熔断器时,应按照额定电压、额定电流和()选择。",[235,237,239,241],{"key":20,"text":236,"correct":22},".额定开断电流",{"key":24,"text":238,"correct":26},".额定功率",{"key":28,"text":240,"correct":26},".额定频率",{"key":31,"text":242,"correct":26},".额定负荷电流",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":24,"analysis":33},716436,"电力系统在运行中发生各种类型短路故障,将伴随着很大的短路电流和()。",[247,249,251],{"key":20,"text":248,"correct":26},".电压升高",{"key":24,"text":250,"correct":22},".电压降低",{"key":28,"text":252,"correct":26},".电压逐渐升高",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":20,"analysis":33},716437,"零序电流II段保护与()构成线路接地短路的主保护。",[257,259,261],{"key":20,"text":258,"correct":22},".零序电流I段保护",{"key":24,"text":260,"correct":26},".瞬时电流速段保护",{"key":28,"text":262,"correct":26},".限时电流速段保护",{"id":264,"libraryId":5,"type":15,"typeLabel":16,"stem":265,"options":266,"answer":28,"analysis":33},716438,"瞬时电流速断保护的主要缺点是()。",[267,269,271],{"key":20,"text":268,"correct":26},".接线复杂",{"key":24,"text":270,"correct":26},".动作时间较长",{"key":28,"text":272,"correct":22},".不能保护线路全长,保护范围受运行方式影响",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":20,"analysis":33},716439,"隔离开关的操作控制回路受断路器和接地刀闸辅助触点控制,只有()的情况下,才可能对隔离开关进行操作。",[277,279,281,283],{"key":20,"text":278,"correct":22},".断路器分闸,接地刀闸拉开",{"key":24,"text":280,"correct":26},".断路器合闸,接地刀闸拉开",{"key":28,"text":282,"correct":26},".断路器分闸,接地刀闸闭合",{"key":31,"text":284,"correct":26},".断路器合闸,接地刀闸闭合",{"id":286,"libraryId":5,"type":15,"typeLabel":16,"stem":287,"options":288,"answer":28,"analysis":33},716440,"电力系统容量超过被供电系统容量()倍时可视为无限大容量电力系统。",[289,290,292],{"key":20,"text":79,"correct":26},{"key":24,"text":291,"correct":26},".20",{"key":28,"text":293,"correct":22},".50",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":24,"analysis":33},716441,"时间继电器电源可取自()。",[298,300,302],{"key":20,"text":299,"correct":26},".交流",{"key":24,"text":301,"correct":22},".交流或直流",{"key":28,"text":303,"correct":26},".直流",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":20,"analysis":33},716442,"高压电动机通常指供电电压等级为()的电动机。",[308,310,312],{"key":20,"text":309,"correct":22},".3-10kV",{"key":24,"text":311,"correct":26},".220V\u002F380V",{"key":28,"text":313,"correct":26},".110kV",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":28,"analysis":33},716443,"变压器励磁涌流中含有明显的高次谐波,其中()分量比例最大。",[318,320,322,324],{"key":20,"text":319,"correct":26},".五次谐波",{"key":24,"text":321,"correct":26},".三次谐波",{"key":28,"text":323,"correct":22},".二次谐波",{"key":31,"text":325,"correct":26},".七次谐波",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":20,"analysis":33},716444,"变压器励磁涌流随时间衰减,衰减速度与()有关。",[330,332,334,336],{"key":20,"text":331,"correct":22},".变压器的容量",{"key":24,"text":333,"correct":26},".变压器的电压等级",{"key":28,"text":335,"correct":26},".变压器的接线组别",{"key":31,"text":337,"correct":26},".变压器合闸相角",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":20,"analysis":33},716445,"当变压器外部故障,差动保护中流入不平衡电流,保护应()。",[342,344,346],{"key":20,"text":343,"correct":22},".不动作",{"key":24,"text":345,"correct":26},".发异常信号",{"key":28,"text":347,"correct":26},".正确动作",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":28,"analysis":33},716446,"零序电流I段为保证选择性,保护范围为()。",[352,354,356],{"key":20,"text":353,"correct":26},".本线路全长",{"key":24,"text":355,"correct":26},".本线路及下级线路全长",{"key":28,"text":357,"correct":22},".本线路一部分",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":20,"analysis":33},716447,"运行统计资料表明,线路重合闸成功率很高,约为()。",[362,364,366,368],{"key":20,"text":363,"correct":22},".60-90%",{"key":24,"text":365,"correct":26},".40-50%",{"key":28,"text":367,"correct":26},".20-30%",{"key":31,"text":369,"correct":26},".80-95%",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":28,"analysis":33},716448,"线路上发生线路倒杆等永久性故障,若使断路器重新合闸时将()。",[374,376,378],{"key":20,"text":375,"correct":26},".可以合闸成功",{"key":24,"text":377,"correct":26},".延时动作,合闸成功",{"key":28,"text":379,"correct":22},".保护动作再次跳闸",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":20,"analysis":33},716449,"电动机容量在()时,纵差动保护采用三相式接线。",[384,386,388],{"key":20,"text":385,"correct":22},".5MW及以上",{"key":24,"text":387,"correct":26},".2MW及以上",{"key":28,"text":389,"correct":26},".2MW以下",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":28,"analysis":33},716450,"时间继电器起动后,经整定的时间延时后动合触点()。",[394,396,398],{"key":20,"text":395,"correct":26},".任意位置",{"key":24,"text":397,"correct":26},".断开",{"key":28,"text":399,"correct":22},".闭合",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":20,"analysis":33},716451,"在检修变压器,要装设接地线时,应()。",[404,406,408],{"key":20,"text":405,"correct":22},"先装接地端,再装导线端",{"key":24,"text":407,"correct":26},"先装中相",{"key":28,"text":409,"correct":26},"先装导线端,再装接地端",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":20,"analysis":33},716452,"电流速断保护主要用于容量为()的电动机。",[414,416,417],{"key":20,"text":415,"correct":22},".小于2MW",{"key":24,"text":387,"correct":26},{"key":28,"text":418,"correct":26},".小于5MW",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":24,"analysis":33},716453,"通过高压、超高压输电线将发电厂与变电站、变电站与变电站连接起来,完成电能传输的电力网络称为()。",[423,425,427],{"key":20,"text":424,"correct":26},".配电网",{"key":24,"text":426,"correct":22},".输电网",{"key":28,"text":428,"correct":26},".电力网",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":28,"analysis":33},716454,"定时限过电流保护远后备灵敏系数要求()。",[433,435,437],{"key":20,"text":434,"correct":26},".小于1.2",{"key":24,"text":436,"correct":26},".大于1.3-1.5",{"key":28,"text":438,"correct":22},".大于1.2",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":28,"analysis":33},716455,"由电流继电器的动作原理可知,电流继电器的返回系数()。",[443,445,447],{"key":20,"text":444,"correct":26},".大于1",{"key":24,"text":446,"correct":26},".等于1",{"key":28,"text":448,"correct":22},".小于1",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":20,"analysis":33},716456,"变压器电流速断保护的灵敏度校验不满足要求时改用()。",[453,455,456,458],{"key":20,"text":454,"correct":22},".差动保护",{"key":24,"text":29,"correct":26},{"key":28,"text":457,"correct":26},".过负荷保护",{"key":31,"text":25,"correct":26},{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":28,"analysis":33},716457,"将变电站中的二次设备经过功能的组合和优化设计,利用先进的计算机技术、现代电子技术、通讯技术和信号处理技术集成为一体化的自动化系统称为()。",[463,465,467,469],{"key":20,"text":464,"correct":26},".自动装置",{"key":24,"text":466,"correct":26},".微机保护系统",{"key":28,"text":468,"correct":22},".变电站自动化",{"key":31,"text":470,"correct":26},".二次系统",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":20,"analysis":33},716458,"某10kV系统输电线路安装了反应故障时电流增大的过电流保护,保护整定电流值为5A,线路末端短路最大三相短路电流为15A,线路末端短路最小两相短路电流为10A,该保护的灵敏系数为()。",[475,477,479,481],{"key":20,"text":476,"correct":22},".2",{"key":24,"text":478,"correct":26},".3",{"key":28,"text":480,"correct":26},".5",{"key":31,"text":482,"correct":26},".1.5",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":24,"analysis":33},716459,"中性点直接接地运行的变压器接地保护,零序电流取自变压器()的电流互感器二次侧。",[487,489,491],{"key":20,"text":488,"correct":26},".低压侧",{"key":24,"text":490,"correct":22},".中性点",{"key":28,"text":492,"correct":26},".高压侧",{"id":494,"libraryId":5,"type":15,"typeLabel":16,"stem":495,"options":496,"answer":20,"analysis":33},716460,"当采用控制开关或通过遥控装置将断路器操作跳闸时,自动重合闸将()。",[497,499,501],{"key":20,"text":498,"correct":22},".不应动作",{"key":24,"text":500,"correct":26},".自动合闸",{"key":28,"text":502,"correct":26},".延时合闸",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":24,"analysis":33},716461,"当限时电流速断保护灵敏度不满足要求时,通常解决灵敏度不足的方法是限时电流速断保护的动作电流及动作时间与()配合。",[507,509,511],{"key":20,"text":508,"correct":26},".下级线路瞬时电流速断保护",{"key":24,"text":510,"correct":22},".下级线路限时电流速断保护",{"key":28,"text":512,"correct":26},".本线路瞬时电流速断保护",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":20,"analysis":33},716462,"变压器差动保护动作电流应按躲过()整定。",[517,519,521,523],{"key":20,"text":518,"correct":22},".最大不平衡电流",{"key":24,"text":520,"correct":26},".最小两相短路电流",{"key":28,"text":522,"correct":26},".最大三相短路电流",{"key":31,"text":524,"correct":26},".最大负荷电流",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":20,"analysis":33},716463,"中性点不接地系统发生单相接地故障,故障线路零序电流方向为()。",[529,531,533],{"key":20,"text":530,"correct":22},".由线路流向母线",{"key":24,"text":532,"correct":26},".由母线流向线路",{"key":28,"text":534,"correct":26},".不确定",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":31,"analysis":33},716464,"目前10kV电网采用的中性点接地低值电阻一般为()。",[539,541,543,545],{"key":20,"text":540,"correct":26},".20Ω",{"key":24,"text":542,"correct":26},".15Ω",{"key":28,"text":544,"correct":26},".5Ω",{"key":31,"text":546,"correct":22},".10Ω",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":28,"analysis":33},716465,"引发电气火灾要具备的两个条件为:现场有()和现场有引燃条件。",[551,553,555],{"key":20,"text":552,"correct":26},"、温度",{"key":24,"text":554,"correct":26},"、湿度",{"key":28,"text":556,"correct":22},"、可燃物质",[558,561,564,566,569,572],{"id":559,"name":560,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":562,"name":563,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":565,"name":563,"category":7,"favorite":8},336,{"id":567,"name":568,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":570,"name":571,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":573,"name":574,"category":7,"favorite":8},353,"(N1)叉车司机"]