[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-18":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,18,50,1668,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":25,"analysis":27},717216,3,"判断题","距离保护装置测量阻抗大于整定阻抗时,说明短路点在保护区内,保护动作。()",[19,23],{"key":20,"text":21,"correct":22},"A","正确",false,{"key":24,"text":25,"correct":26},"B","错误",true,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},717217,"电流速断保护在电动机起动时不应动作。()",[32,33],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":21,"analysis":27},717218,"运行经验表明,架空线路故障的性质大多为瞬时性故障。()",[38,39],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":21,"analysis":27},717219,"高压电动机运行中可能发生的主要故障有电动机定子绕组的相间短路故障、单相接地短路以及一相绕组的匝间短路。()",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},717220,"变压器励磁涌流中含有明显的高次谐波,其中二次谐波分量比例最大。()",[50,51],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},717221,"定时限过电流保护远后备灵敏度系数要求大于等于1.2。()",[56,57],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":25,"analysis":27},717222,"在电力系统事故情况下,可能出现较大的有功功率缺额,造成电力系统电压较大幅度下降。()",[62,63],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":25,"analysis":27},717223,"电动机纵差动保护接线时,机端电流互感器与中性点侧电流互感器,型号不同,变比不同。()",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},717224,"根据变压器励磁涌流特点,当鉴别是励磁涌流时须闭锁保护。()",[74,75],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":21,"analysis":27},717225,"电力系统中采用电压互感器可以使二次设备与一次高压隔离,保证工作人员的安全。()",[80,81],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},717226,"电动机低定值电流速断保护在电动机起动时投入。()",[86,87],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":25,"analysis":27},717227,"变压器异常运行包括过负荷、引出线的套管闪络故障及外部短路引起的过电流等。()",[92,93],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":25,"analysis":27},717228,"采用二次谐波制动原理构成的变压器差动保护,当出现短路电流时闭锁保护。()",[98,99],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":21,"analysis":27},717229,"能够使低电压继电器开始动作的最大电压称为低电压继电器的动作电压。()",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":21,"analysis":27},717230,"旋转电机发生火灾时,禁止使用干粉灭火器和干沙直接灭火。",[110,111],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":25,"analysis":27},717231,"变电站自动化系统按系统结构可分为主从式、分布式和分散式三种类型。()",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":25,"analysis":27},717232,"变压器励磁电流存在于电源侧及负荷侧。()",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":21,"analysis":27},717233,"纵差动保护主要用于容量为2MW及以上的电动机。()",[128,129],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":21,"analysis":27},717234,"中性点不接地系统是指电力系统中性点不接地。()",[134,135],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":21,"analysis":27},717235,"变压器相间短路的后备保护作为变压器差动保护或电流速断保护和气体保护的后备保护。()",[140,141],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},717236,"自动重合闸装置按照重合闸作用断路器的方式可分为三相重合闸、单相重合闸和综合重合闸。()",[146,147],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":21,"analysis":27},717237,"零序电流的大小可根据表达式30=A+B+C求得。()",[152,153],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":21,"analysis":27},717238,"电力网主要由送电线路、变电所、配电所和配电线路组成。()",[158,159],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":21,"analysis":27},717239,"变压器正常运行时励磁电流一般约为变压器额定电流的3%-5%。()",[164,165],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},717240,"当继电保护或断路器拒动,后备保护切除故障时保证停电范围尽可能小是指保护具有较好的选择性。()",[170,171],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":25,"analysis":27},717241,"时间继电器起动后,经整定的时间延时后动合触点断开。()",[176,177],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":21,"analysis":27},717242,"电压互感器二次必须装设一个保安接地点,以防止互感器一、二次绕组绝缘击穿时危及设备和人身安全。()",[182,183],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":21,"analysis":27},717243,"变压器电流速断保护作为变压器的主保护,动作时间为0S。()",[188,189],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":25,"analysis":27},717244,"距离保护装置反应电流增大而动作。()",[194,195],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":25,"analysis":27},717245,"电动机运行中被过热保护跳闸后,随着散热使积累热量减小到过热积累闭锁电动机再起动定值时,电动机禁止再起动回路解除,电动机不能再起动()。",[200,201],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":21,"analysis":27},717246,"高压电动机发生单相接地故障时应视接地电流大小可切除电动机或发出报警信号。()",[206,207],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":25,"analysis":27},717247,"电力系统发生相间短路时的主要特征是电流减小。()",[212,213],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},717248,"低电压保护用于反应电动机匝间短路、断相、相序接反以及供电电压较大不平衡的保护。()",[218,219],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":25,"analysis":27},717249,"断路器位置信号中,当断路器在合闸位置时绿灯亮。()",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":21,"analysis":27},717250,"电动机的外部发生两相短路,电动机的负序电流大于正序电流。()",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":21,"analysis":27},717251,"当工作电源因故障自动跳闸后,自动迅速地将备用电源投入的一种自动装置称为备用电源自动投入装置。()",[236,237],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":21,"analysis":27},717252,"阶段式零序电流保护具有灵敏度高、延时小以及保护范围受系统运行方式影响小的特点。()",[242,243],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},717253,"零序电压可采用三个单相式电压互感器取得。()",[248,249],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":25,"analysis":27},717254,"在使用跌落式熔断器时,应按照额定电压、额定电流和额定负荷电流选择。()",[254,255],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":25,"analysis":27},717255,"在正常情况下没有断开的备用电源或备用线路,而是工作在分段母线状态,靠分段断路器取得相互备用的备用方式称为明备用。()",[260,261],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":21,"analysis":27},717256,"变压器内部发生严重故障时,油箱内产生大量气体,使重瓦斯继电器动作,接通保护跳闸回路,断开变压器各侧断路器。()",[266,267],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":21,"analysis":27},717257,"备用电源自动投入装置工作时,当工作母线不论任何原因电压消失,备用电源均应投入。()",[272,273],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":25,"analysis":27},717258,"低电压继电器动作后,使继电器返回到原始状态的最大电压称为低电压继电器的返回电压。()",[278,279],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":25,"analysis":27},717259,"瞬时电流速断保护动作电流的整定原则为躲过本线路末端短路可能出现的最大负荷电流。()",[284,285],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":21,"analysis":27},717260,"变压器故障分为油箱内故障和油箱外故障两大类。()",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":21,"analysis":27},717261,"对运行中可能产生电火花、电弧和高温危险的电气设备和装置,不应放置在易燃的危险场所。()",[296,297],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},717262,"电力系统中母线发生故障,故障的性质绝大部分为永久性故障。()",[302,303],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":21,"analysis":27},717263,"一般把继电保护动作值、动作时间的计算和灵敏度的校验称为继电保护的整定计算。()",[308,309],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":21,"analysis":27},717264,"对于容量在6300kVA以上的并列运行变压器或企业中的重要变压器应装设纵差动保护。()",[314,315],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":21,"analysis":27},717265,"信号继电器在继电保护中主要实现继电保护动作信号。()",[320,321],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[323,327,330,332,335,338],{"id":324,"name":325,"category":7,"favorite":326},401,"高处安装、维护、拆除",1,{"id":328,"name":329,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":331,"name":329,"category":7,"favorite":8},336,{"id":333,"name":334,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":336,"name":337,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":339,"name":340,"category":7,"favorite":8},353,"(N1)叉车司机"]