[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-17":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":322},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,17,50,1668,[13,28,34,40,46,52,58,64,70,76,82,88,94,100,106,112,118,124,130,136,142,148,154,160,166,172,178,184,190,196,202,208,214,220,226,232,238,244,250,256,262,268,274,280,286,292,298,304,310,316],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":21,"analysis":27},717166,3,"判断题","线路上发生线路倒杆等永久性故障,当使断路器重新合闸时保护将动作再次跳闸。()",[19,23],{"key":20,"text":21,"correct":22},"A","正确",true,{"key":24,"text":25,"correct":26},"B","错误",false,"",{"id":29,"libraryId":5,"type":15,"typeLabel":16,"stem":30,"options":31,"answer":21,"analysis":27},717167,"中性点不接地系统通常采用绝缘监视和接地选线的方式实现单相接地保护。()",[32,33],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":25,"analysis":27},717168,"高压电动机运行常见的异常运行状态有:起动时间过长、定子绕组的相间短路故障或三相不平衡、堵转、过负荷引起的过电流、供电电压过低或过高。()",[38,39],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":41,"libraryId":5,"type":15,"typeLabel":16,"stem":42,"options":43,"answer":25,"analysis":27},717169,"微机保护通过A\u002FD获得输入电压、电流的模拟量的过程称为多路转换。()",[44,45],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":21,"analysis":27},717170,"发电厂、变电站的电气系统,按其作用分为一次系统和和二次系统。()",[50,51],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":21,"analysis":27},717171,"继电保护装置是在电力系统故障或异常运行情况下动作的一种自动装置。()",[56,57],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":21,"analysis":27},717172,"在使用跌落式熔断器时,应按照额定电压、额定电流和额定开断电流选择。()",[62,63],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":21,"analysis":27},717173,"电力系统出现过负荷、频率降低、过电压等属于异常运行状态。()",[68,69],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":21,"analysis":27},717174,"电流互感器的接线方式中,三相都装有电流互感器以及相应的电流元件,能够反应三相电流的接线方式为三相完全星形接线。()",[74,75],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":25,"analysis":27},717175,"隔离开关控制方式中,电压等级为220kV及以上的隔离开关采用就地控制。()",[80,81],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":25,"analysis":27},717176,"对中、小容量的变压器,可以装设单独的电流速断保护,与过电流保护一起作为变压器的主保护。()",[86,87],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":21,"analysis":27},717177,"利用变压器励磁涌流中含有明显的二次谐波分量的特征,通常采用二次谐波制动原理构成变压器差动保护。()",[92,93],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":21,"analysis":27},717178,"变压器电流速断保护动作电流按躲过变压器负荷侧母线短路时流过保护的最大短路电流,并躲过变压器空载投入时的励磁涌流整定。()",[98,99],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":25,"analysis":27},717179,"电动机堵转保护采用负序电流构成。()",[104,105],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":25,"analysis":27},717180,"零序电流的大小不仅与中性点接地的变压器的种类有关,而且与系统运行方式有关。()",[110,111],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":21,"analysis":27},717181,"上下级定时限过电流保护按照选择性要求,上级线路比下级线路动作时间大。()",[116,117],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":21,"analysis":27},717182,"电流互感器二次回路不能装设熔断器,不设置切换回路,防止电流互感器二次回路开路。()",[122,123],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":25,"analysis":27},717183,"在变压器差动保护中,由于两侧电流互感器二次阻抗不完全匹配造成的不平衡电流在计算时引入电流互感器同型系数、电压平衡调整及非周期分量系数等措施。()",[128,129],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":25,"analysis":27},717184,"低电压继电器的动作电压与返回电压之比称为低电压继电器的返回系数。()",[134,135],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":21,"analysis":27},717185,"高压电动机发生定子绕组的相间短路故障时要求尽快切除故障电动机。()",[140,141],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":21,"analysis":27},717186,"变压器保护中过电流保护、零序电流保护为变压器的后备保护。()",[146,147],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":21,"analysis":27},717187,"电动机装设过电压保护,当三个相间电压均高于整定值时,保护经延时跳闸。()",[152,153],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":21,"analysis":27},717188,"备用电源自动投入装置动作时间应以负荷停电时间尽可能短为原则,以减少电动机的自起动时间。",[158,159],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":25,"analysis":27},717189,"断路器事故跳闸时,发出蜂鸣器音响信号,即预告信号。()",[164,165],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":21,"analysis":27},717190,"电动机电流速断保护低定值按照躲过外部故障切除后电动机的最大起动电流,以及外部三相短路故障时电动机向外提供的最大反馈电流整定。()",[170,171],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":21,"analysis":27},717191,"常用的电压互感器接线方式有星形接线、V-V接线、两相电流差接线等。()",[176,177],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":25,"analysis":27},717192,"限时电流速断保护的要求是,保护范围在任何情况下必须包括本线路及下级线路全长,并具有规定的灵敏度。()",[182,183],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":21,"analysis":27},717193,"瞬时电流速断保护对单侧有电源的辐射性电网,保护范围为本线路一部分。()",[188,189],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":25,"analysis":27},717194,"采用二次谐波制动原理的变压器差动保护,当二次谐波含量低于定值时闭锁差动保护。()",[194,195],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":25,"analysis":27},717195,"电流互感器的接线方式中,只有二相装有电流互感器和一个电流元件,流入电流元件的电流为两相电流差的接线方式为两相不完全星形接线。()",[200,201],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":25,"analysis":27},717196,"对单侧有电源的辐射形电网,瞬时电流速断保护对下级线路故障应动作。()",[206,207],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":21,"analysis":27},717197,"电动机纵差动保护接线时,要求机端电流互感器与中性点侧电流互感器型号相同,变比相同。()",[212,213],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":25,"analysis":27},717198,"电动机运行时,当三个相间电压均低于整定值时,低电压保护发出异常信号。()",[218,219],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":21,"analysis":27},717199,"外部故障时变压器差动保护中,流入差动继电器的电流为不平衡电流。()",[224,225],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":25,"analysis":27},717200,"电动机负序电流保护主要针对各种非接地的对称故障。()",[230,231],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":25,"analysis":27},717201,"变压器差动保护的差动元件,当任一差动元件动作时保护即出口跳闸称为分相制动。()",[236,237],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":21,"analysis":27},717202,"中间继电器可用于增加触点容量、接通断路器的跳闸回路。()",[242,243],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":21,"analysis":27},717203,"对于容量在800kVA及以上的油浸式变压器以及400kVA及以上的车间内油浸式变压器,应装设瓦斯保护。()",[248,249],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":251,"libraryId":5,"type":15,"typeLabel":16,"stem":252,"options":253,"answer":25,"analysis":27},717204,"电动机的过负荷保护的动作时间与电动机的最大允许堵转时间相配合。()",[254,255],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":21,"analysis":27},717205,"零序电流通常采用零序电流滤过器取得。()",[260,261],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":263,"libraryId":5,"type":15,"typeLabel":16,"stem":264,"options":265,"answer":25,"analysis":27},717206,"电动机单相接地故障的自然接地电流(未补偿过的电流)大于5A时需装设低电压保护。()",[266,267],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":25,"analysis":27},717207,"继电保护系统检出任何故障或异常情况时,都将发出跳闸命令将设备从系统中切除。()",[272,273],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":25,"analysis":27},717208,"电动机堵转保护在电动机起动结束后退出。()",[278,279],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":21,"analysis":27},717209,"变压器励磁涌流中含有明显的非周期分量,波形偏向时间轴的一侧。()",[284,285],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":25,"analysis":27},717210,"变压器差动保护的差动元件通常采用比率制动特性,引入外部电压作为制动量。()",[290,291],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":25,"analysis":27},717211,"瞬时电流速断保护的主要优点是可保护本线路全长。()",[296,297],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},{"id":299,"libraryId":5,"type":15,"typeLabel":16,"stem":300,"options":301,"answer":21,"analysis":27},717212,"安装接线图包括屏面布置图、屏背面接线图及端子排图。()",[302,303],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":21,"analysis":27},717213,"继电保护根据所承担的任务分为主保护和后备保护。()",[308,309],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":21,"analysis":27},717214,"电动机运行中被过热保护跳闸后,随着散热使积累热量减小到过热积累闭锁电动机再起动定值时,电动机禁止再起动回路解除,电动机可以再起动()。",[314,315],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":25,"analysis":27},717215,"电力系统中变压器通常采用Y,d11接线方式,两侧线电流的相位相差60°。",[320,321],{"key":20,"text":21,"correct":26},{"key":24,"text":25,"correct":22},[323,327,330,332,335,338],{"id":324,"name":325,"category":7,"favorite":326},401,"高处安装、维护、拆除",1,{"id":328,"name":329,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":331,"name":329,"category":7,"favorite":8},336,{"id":333,"name":334,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":336,"name":337,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":339,"name":340,"category":7,"favorite":8},353,"(N1)叉车司机"]