[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-15":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":350},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,15,50,1668,[13,34,44,56,66,76,86,92,98,104,110,116,122,128,134,140,146,152,158,164,170,176,182,188,194,200,206,212,218,224,230,236,242,248,254,260,266,272,278,284,290,296,302,308,314,320,326,332,338,344],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},717066,1,"单选题","备用电源自动投入的一次接线方案按照备用方式可以分为明备用和()方式。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A",".线路备用",false,{"key":24,"text":25,"correct":26},"B",".暗备用",true,{"key":28,"text":29,"correct":22},"C",".变压器备用",{"key":31,"text":32,"correct":22},"D",".母线备用","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},717067,"在电力系统中无功功率必须留有足够的运行备用容量,在可能发生电压崩溃的负荷中心区域,采用按()降低自动减负荷装置。",[38,40,42],{"key":20,"text":39,"correct":22},".频率",{"key":24,"text":41,"correct":22},".电流",{"key":28,"text":43,"correct":26},".电压",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":28,"analysis":33},717068,"变压器保护中()为变压器及相邻元件接地故障的后备保护。",[48,50,52,54],{"key":20,"text":49,"correct":22},".过电流保护",{"key":24,"text":51,"correct":22},".过负荷保护",{"key":28,"text":53,"correct":26},".零序电流保护",{"key":31,"text":55,"correct":22},".速断电流保护",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":20,"analysis":33},717069,"电力系统中变压器通常采用Y,d11接线方式,为使变压器差动保护回路正常时电流为0,电流互感器二次绕组采用(),变比调整为原来的1.732倍。",[60,62,64],{"key":20,"text":61,"correct":26},".三角形接线",{"key":24,"text":63,"correct":22},".Y形接线",{"key":28,"text":65,"correct":22},".三角形及Y形接线任一种",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":20,"analysis":33},717070,"三段式零序电流保护中第I段为()。",[70,72,74],{"key":20,"text":71,"correct":26},".瞬时零序电流速断保护",{"key":24,"text":73,"correct":22},".限时零序电流速断保护",{"key":28,"text":75,"correct":22},".零序过电流保护",{"id":77,"libraryId":5,"type":78,"typeLabel":79,"stem":80,"options":81,"answer":83,"analysis":33},717071,3,"判断题","微机保护通过A\u002FD获得输入电压、电流的模拟量的过程称为采样。()",[82,84],{"key":20,"text":83,"correct":26},"正确",{"key":24,"text":85,"correct":22},"错误",{"id":87,"libraryId":5,"type":78,"typeLabel":79,"stem":88,"options":89,"answer":83,"analysis":33},717072,"对中、小容量的变压器,可以装设单独的电流速断保护,与气体保护配合构成变压器的主保护。()",[90,91],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":93,"libraryId":5,"type":78,"typeLabel":79,"stem":94,"options":95,"answer":85,"analysis":33},717073,"变压器正常运行时励磁电流一般约为变压器额定电流的6-8倍。()",[96,97],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":99,"libraryId":5,"type":78,"typeLabel":79,"stem":100,"options":101,"answer":85,"analysis":33},717074,"备用电源自动投入装置工作时,当电压互感器二次断线时,自投装置应延时动作。()",[102,103],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":105,"libraryId":5,"type":78,"typeLabel":79,"stem":106,"options":107,"answer":83,"analysis":33},717075,"当低电压继电器动作时,动断触点闭合。()",[108,109],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":111,"libraryId":5,"type":78,"typeLabel":79,"stem":112,"options":113,"answer":85,"analysis":33},717076,"断路器“防跳”措施有手动防跳和电气防跳两种。()",[114,115],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":117,"libraryId":5,"type":78,"typeLabel":79,"stem":118,"options":119,"answer":83,"analysis":33},717077,"采用二次谐波制动原理的变压器差动保护,当二次谐波含量低于定值时开放差动保护。()",[120,121],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":123,"libraryId":5,"type":78,"typeLabel":79,"stem":124,"options":125,"answer":83,"analysis":33},717078,"当电动机供电网络电压降低后恢复,电动机自起动时起动电流大于额定电流。()",[126,127],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":129,"libraryId":5,"type":78,"typeLabel":79,"stem":130,"options":131,"answer":85,"analysis":33},717079,"电动机在起动过程中或运行中发生堵转,转差率为0.5。()",[132,133],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":135,"libraryId":5,"type":78,"typeLabel":79,"stem":136,"options":137,"answer":83,"analysis":33},717080,"电动机电流速断保护高定值按照躲过电动机的最大起动电流整定。()",[138,139],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":141,"libraryId":5,"type":78,"typeLabel":79,"stem":142,"options":143,"answer":85,"analysis":33},717081,"从屏背面看,屏内安装设备接线所需的各类端子排列,表明屏内设备连接与屏顶设备、屏外设备连接关系的图纸为屏背面接线图。()",[144,145],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":147,"libraryId":5,"type":78,"typeLabel":79,"stem":148,"options":149,"answer":83,"analysis":33},717082,"电压互感器是将交流一次侧高电压转换成可供控制、测量、保护等二次设备使用的二次侧电压的变压设备。()",[150,151],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":153,"libraryId":5,"type":78,"typeLabel":79,"stem":154,"options":155,"answer":83,"analysis":33},717083,"微机保护具有信号测量、逻辑判断、出口执行等布线逻辑保护的功能。()",[156,157],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":159,"libraryId":5,"type":78,"typeLabel":79,"stem":160,"options":161,"answer":83,"analysis":33},717084,"蓄电池-充电机直流电源系统有充电-放电运行方式和浮充电运行方式。()",[162,163],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":165,"libraryId":5,"type":78,"typeLabel":79,"stem":166,"options":167,"answer":85,"analysis":33},717085,"电动机装设过电压保护,当三个相间电压均高于整定值时,保护不应动作。()",[168,169],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":171,"libraryId":5,"type":78,"typeLabel":79,"stem":172,"options":173,"answer":83,"analysis":33},717086,"微机保护的基本构成包括硬件和软件。()",[174,175],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":177,"libraryId":5,"type":78,"typeLabel":79,"stem":178,"options":179,"answer":85,"analysis":33},717087,"继电保护装置中电流继电器接在电压互感器的二次测。()",[180,181],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":183,"libraryId":5,"type":78,"typeLabel":79,"stem":184,"options":185,"answer":83,"analysis":33},717088,"电流互感器的接线方式中,只有二相装有电流互感器以及相应的电流元件,只能反应二相电流的接线方式为两相不完全星形接线。()",[186,187],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":189,"libraryId":5,"type":78,"typeLabel":79,"stem":190,"options":191,"answer":85,"analysis":33},717089,"中性点直接接地系统发生接地故障时,在三相中将产生大小相等、相位相差120度的零序电压与零序电流。()",[192,193],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":195,"libraryId":5,"type":78,"typeLabel":79,"stem":196,"options":197,"answer":85,"analysis":33},717090,"变压器过负荷保护一般接三相电流,经过延时发出信号。()",[198,199],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":201,"libraryId":5,"type":78,"typeLabel":79,"stem":202,"options":203,"answer":83,"analysis":33},717091,"靠近线路电源端与靠近线路负荷端的定时限过电流保护,靠近线路电源端动作时间整定值大。()",[204,205],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":207,"libraryId":5,"type":78,"typeLabel":79,"stem":208,"options":209,"answer":85,"analysis":33},717092,"异常运行情况发生时,瞬时或延时发出警铃音响信号,即事故信号。()",[210,211],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":213,"libraryId":5,"type":78,"typeLabel":79,"stem":214,"options":215,"answer":85,"analysis":33},717093,"电动机负序电流保护动作于减负荷。()",[216,217],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":219,"libraryId":5,"type":78,"typeLabel":79,"stem":220,"options":221,"answer":85,"analysis":33},717094,"本线路的限时电流速断保护与下级线路瞬时电流速断保护范围有重叠区,当在重叠区发生故障时将由前者动作跳闸。()",[222,223],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":225,"libraryId":5,"type":78,"typeLabel":79,"stem":226,"options":227,"answer":85,"analysis":33},717095,"变压器过电流保护的电流元件的动作电流按躲过变压器可能出现的励磁涌流整定。()",[228,229],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":231,"libraryId":5,"type":78,"typeLabel":79,"stem":232,"options":233,"answer":83,"analysis":33},717096,"当变压器发生内部严重故障时,引起电流互感器饱和,二次电流波形发生畸变,变压器差动速断元件将可靠动作。()",[234,235],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":237,"libraryId":5,"type":78,"typeLabel":79,"stem":238,"options":239,"answer":83,"analysis":33},717097,"变压器发生故障后,应该立即将变压器从系统中切除。()",[240,241],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":243,"libraryId":5,"type":78,"typeLabel":79,"stem":244,"options":245,"answer":83,"analysis":33},717098,"从屏正面看,将各安装设备的实际安装位置按比例画出的正视图为屏面布置图。()",[246,247],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":249,"libraryId":5,"type":78,"typeLabel":79,"stem":250,"options":251,"answer":85,"analysis":33},717099,"电流速断保护在电动机起动时应可靠动作。()",[252,253],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":255,"libraryId":5,"type":78,"typeLabel":79,"stem":256,"options":257,"answer":85,"analysis":33},717100,"对于容量在800kVA及以上且电流速断保护灵敏度不满足要求的变压器应装设纵差动保护。()",[258,259],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":261,"libraryId":5,"type":78,"typeLabel":79,"stem":262,"options":263,"answer":83,"analysis":33},717101,"分立元件构成的继电保护二次接线图,按照其用途可分为原理接线图和安装接线图。()",[264,265],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":267,"libraryId":5,"type":78,"typeLabel":79,"stem":268,"options":269,"answer":85,"analysis":33},717102,"中性点不接地系统发生接地短路时产生很大的短路电流,要求继电保护必须及时动作切除故障,保证设备和系统的安全。()",[270,271],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":273,"libraryId":5,"type":78,"typeLabel":79,"stem":274,"options":275,"answer":85,"analysis":33},717103,"按电压降低自动减负荷装置的低电压元件的整定值应低于电压崩溃的临界电压,并留有一定的裕度。()",[276,277],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":279,"libraryId":5,"type":78,"typeLabel":79,"stem":280,"options":281,"answer":83,"analysis":33},717104,"按功能模块设计,采用主从CPU协同工作方式,各功能模块之间无通讯,由监控主机与各功能子系统通讯的方式称为分布式变电站自动化系统。()",[282,283],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":285,"libraryId":5,"type":78,"typeLabel":79,"stem":286,"options":287,"answer":85,"analysis":33},717105,"备用电源自动投入装置工作时,备用电源投入到持续性故障上,备用电源断路器将断开后,再次投入。()",[288,289],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":291,"libraryId":5,"type":78,"typeLabel":79,"stem":292,"options":293,"answer":83,"analysis":33},717106,"电动机的相间短路保护动作于跳闸。()",[294,295],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":297,"libraryId":5,"type":78,"typeLabel":79,"stem":298,"options":299,"answer":85,"analysis":33},717107,"零序电流III段保护动作电流的整定原则为躲过线路最大负荷电流。()",[300,301],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":303,"libraryId":5,"type":78,"typeLabel":79,"stem":304,"options":305,"answer":83,"analysis":33},717108,"变压器气体保护的范围为变压器油箱内部。()",[306,307],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":309,"libraryId":5,"type":78,"typeLabel":79,"stem":310,"options":311,"answer":85,"analysis":33},717109,"频率是电力系统运行的一个重要指标,反应电力系统无功功率供需平衡的状态。()",[312,313],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":315,"libraryId":5,"type":78,"typeLabel":79,"stem":316,"options":317,"answer":85,"analysis":33},717110,"电动机的过负荷保护的动作时间与电动机的最大允许过热时间相配合。()",[318,319],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":321,"libraryId":5,"type":78,"typeLabel":79,"stem":322,"options":323,"answer":83,"analysis":33},717111,"微机保护采样时,采样频率fs与采样信号中所含最高频率成分fmax的频率的关系为fs&gt;2fmax。()",[324,325],{"key":20,"text":83,"correct":26},{"key":24,"text":85,"correct":22},{"id":327,"libraryId":5,"type":78,"typeLabel":79,"stem":328,"options":329,"answer":85,"analysis":33},717112,"变压器低电压起动的过电流保护由电流元件、电压元件和功率元件构成。()",[330,331],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":333,"libraryId":5,"type":78,"typeLabel":79,"stem":334,"options":335,"answer":85,"analysis":33},717113,"三段式零序电流保护中第II段为零序过电流保护。()",[336,337],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":339,"libraryId":5,"type":78,"typeLabel":79,"stem":340,"options":341,"answer":85,"analysis":33},717114,"变压器瓦斯保护接线中切换片XB有两个位置,即跳闸位置和合闸位置。()",[342,343],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},{"id":345,"libraryId":5,"type":78,"typeLabel":79,"stem":346,"options":347,"answer":85,"analysis":33},717115,"瞬时电流速断保护的选择性用最小保护范围衡量。()",[348,349],{"key":20,"text":83,"correct":22},{"key":24,"text":85,"correct":26},[351,354,357,359,362,365],{"id":352,"name":353,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":355,"name":356,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":358,"name":356,"category":7,"favorite":8},336,{"id":360,"name":361,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":363,"name":364,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":366,"name":367,"category":7,"favorite":8},353,"(N1)叉车司机"]