[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-14":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":545},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,14,50,1668,[13,31,44,54,64,76,88,98,108,118,128,140,149,161,173,183,193,205,215,227,239,251,261,271,283,292,302,314,324,333,343,353,363,373,383,393,403,413,425,435,445,455,464,476,486,496,506,516,525,534],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":30},717016,1,"单选题","电动机堵转保护在电动机起动时()。",[19,23,27],{"key":20,"text":21,"correct":22},"A",".退出",true,{"key":24,"text":25,"correct":26},"B",".投入",false,{"key":28,"text":29,"correct":26},"C",".动作","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":20,"analysis":30},717017,"变电站自动化系统按系统结构可分为集中式、()和分散式三种类型。",[35,37,39,41],{"key":20,"text":36,"correct":22},".分布式",{"key":24,"text":38,"correct":26},".微机式",{"key":28,"text":40,"correct":26},".现场式",{"key":42,"text":43,"correct":26},"D",".主从式",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":20,"analysis":30},717018,"跌落式熔断器主要用作配电变压器、()、短段电缆线路、架空线路分段或分支线路的短路故障保护。",[48,50,52],{"key":20,"text":49,"correct":22},".电容组",{"key":24,"text":51,"correct":26},".高压输电线路",{"key":28,"text":53,"correct":26},".远距离电缆线路",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":20,"analysis":30},717019,"高压电动机通常装设纵差动保护或电流速断保护、负序电流保护、起动时间过长保护、过热保护、()、过电流保护、单相接地保护、低电压保护等。",[58,60,62],{"key":20,"text":59,"correct":22},".堵转保护",{"key":24,"text":61,"correct":26},".瓦斯保护",{"key":28,"text":63,"correct":26},".气体保护",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":42,"analysis":30},717020,"备用电源自动投入的一次接线方案按照备用方式可以分为()和暗备用方式。",[68,70,72,74],{"key":20,"text":69,"correct":26},".线路备用",{"key":24,"text":71,"correct":26},".母线备用",{"key":28,"text":73,"correct":26},".变压器备用",{"key":42,"text":75,"correct":22},".明备用",{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":28,"analysis":30},717021,"变压器气体保护用于反应变压器油箱内部的各种故障以及()。",[80,82,84,86],{"key":20,"text":81,"correct":26},".过负荷",{"key":24,"text":83,"correct":26},".引出线的套管闪络故障",{"key":28,"text":85,"correct":22},".油箱漏油等造成油面降低",{"key":42,"text":87,"correct":26},".引出线上的相间故障",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":24,"analysis":30},717022,"当采用控制开关或通过遥控装置将断路器操作合闸于故障线路时,继电保护动作将断路器跳闸,自动重合闸将()。",[92,94,96],{"key":20,"text":93,"correct":26},".自动合闸",{"key":24,"text":95,"correct":22},".不应动作",{"key":28,"text":97,"correct":26},".延时合闸",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":24,"analysis":30},717023,"下列保护中()是用于反应电动机匝间、断相、相序接反以及供电电压较大不平衡的保护。",[102,104,106],{"key":20,"text":103,"correct":26},".低电压保护",{"key":24,"text":105,"correct":22},".负序电流保护",{"key":28,"text":107,"correct":26},".过热保护",{"id":109,"libraryId":5,"type":15,"typeLabel":16,"stem":110,"options":111,"answer":20,"analysis":30},717024,"电动机纵差动保护接线采用比率制动特性,应保证躲过正常运行时、外部三相短路电动机向外供给短路电流时以及()差动回路的不平衡电流。",[112,114,116],{"key":20,"text":113,"correct":22},".电动机全电压起动时",{"key":24,"text":115,"correct":26},".内部三相短路时",{"key":28,"text":117,"correct":26},".内部两相短路时",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":30},717025,"本线路的限时电流速断保护动作电流的整定原则为()。",[122,124,126],{"key":20,"text":123,"correct":22},".与下级线路瞬时电流速断保护配合",{"key":24,"text":125,"correct":26},".与本线路瞬时电流速断保护配合",{"key":28,"text":127,"correct":26},".与下级线路限时电流速断保护配合",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":42,"analysis":30},717026,"变压器差动保护反应()而动作。",[132,134,136,138],{"key":20,"text":133,"correct":26},".功率方向",{"key":24,"text":135,"correct":26},".变压器电流升高",{"key":28,"text":137,"correct":26},".变压器电压降低",{"key":42,"text":139,"correct":22},".变压器两侧电流的大小和相位",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":42,"analysis":30},717027,"在正常情况下有明显断开的备用电源或备用线路的备用方式称为()。",[144,146,147,148],{"key":20,"text":145,"correct":26},".暗备用",{"key":24,"text":71,"correct":26},{"key":28,"text":73,"correct":26},{"key":42,"text":75,"correct":22},{"id":150,"libraryId":5,"type":15,"typeLabel":16,"stem":151,"options":152,"answer":28,"analysis":30},717028,"实际中减少差动回路不平衡电流的主要措施是,两侧电流互感器要匹配及()等。",[153,155,157,159],{"key":20,"text":154,"correct":26},".采用二次谐波制动",{"key":24,"text":156,"correct":26},".采用间断角原理制动",{"key":28,"text":158,"correct":22},".减小电流互感器二次负载阻抗",{"key":42,"text":160,"correct":26},".电压平衡调整",{"id":162,"libraryId":5,"type":15,"typeLabel":16,"stem":163,"options":164,"answer":28,"analysis":30},717029,"某变电站为监测线路接地故障情况,其电压互感器接线方式应选用()。",[165,167,169,171],{"key":20,"text":166,"correct":26},".星形接线",{"key":24,"text":168,"correct":26},".两相电流差接线",{"key":28,"text":170,"correct":22},".开口三角形接线",{"key":42,"text":172,"correct":26},".V-V接线",{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":24,"analysis":30},717030,"零序电压通常采用三相五柱式电压互感器或()取得。",[177,179,181],{"key":20,"text":178,"correct":26},".三个单相式电流互感器",{"key":24,"text":180,"correct":22},".三个单相式电压互感器",{"key":28,"text":182,"correct":26},".一个单相式电流互感器",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":28,"analysis":30},717031,"变压器过负荷保护动作后()。",[187,189,191],{"key":20,"text":188,"correct":26},".给出轻瓦斯信号",{"key":24,"text":190,"correct":26},".跳开变压器各侧断路器",{"key":28,"text":192,"correct":22},".延时动作于信号",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":28,"analysis":30},717032,"变压器过负荷保护用于反应()。",[197,199,201,203],{"key":20,"text":198,"correct":26},".外部故障引起的过电流",{"key":24,"text":200,"correct":26},".油箱漏油造成油面降低",{"key":28,"text":202,"correct":22},".容量在400kV及以上变压器的三相对称过负荷",{"key":42,"text":204,"correct":26},".变压器高压侧系统的接地故障",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":24,"analysis":30},717033,"本线路的限时电流速断保护与下级线路瞬时电流速断保护范围有重叠区,当在重叠区发生故障时由()。",[209,211,213],{"key":20,"text":210,"correct":26},".本线路的限时电流速断保护动作跳闸",{"key":24,"text":212,"correct":22},".下级线路瞬时电流速断保护动作跳闸",{"key":28,"text":214,"correct":26},".均动作跳闸",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":24,"analysis":30},717034,"电力系统发生的接地故障,包括单相接地故障和()。",[219,221,223,225],{"key":20,"text":220,"correct":26},".两相故障",{"key":24,"text":222,"correct":22},".两相接地故障",{"key":28,"text":224,"correct":26},".三相故障",{"key":42,"text":226,"correct":26},".两相断线故障",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":28,"analysis":30},717035,"某变电站的一条线路采用电流三段式保护,其中限时电流速断的整定值为10A,在线路末端发生相间故障时,最大短路电流(最大运行方式下三相短路)为30A,最小短路电流(最小运行方式下两相短路)为15A,则限时电流速断保护的灵敏系数为()。",[231,233,235,237],{"key":20,"text":232,"correct":26},".3",{"key":24,"text":234,"correct":26},".2",{"key":28,"text":236,"correct":22},".1.5",{"key":42,"text":238,"correct":26},".4",{"id":240,"libraryId":5,"type":15,"typeLabel":16,"stem":241,"options":242,"answer":42,"analysis":30},717036,"变压器瓦斯保护接线中切换片XB有两个位置,即跳闸位置和()。",[243,245,247,249],{"key":20,"text":244,"correct":26},".重合闸位置",{"key":24,"text":246,"correct":26},".合闸位置",{"key":28,"text":248,"correct":26},".试验位置",{"key":42,"text":250,"correct":22},".信号位置",{"id":252,"libraryId":5,"type":15,"typeLabel":16,"stem":253,"options":254,"answer":28,"analysis":30},717037,"发现触电伤员呼吸、心跳停止时,应立即在现场用()就地抢救,以支持呼吸和循环。",[255,257,259],{"key":20,"text":256,"correct":26},"紧急救护法",{"key":24,"text":258,"correct":26},"人工呼吸法",{"key":28,"text":260,"correct":22},"心肺复苏法",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":24,"analysis":30},717038,"继电保护装置中低电压继电器反应()而动作。",[265,267,269],{"key":20,"text":266,"correct":26},".电压增大",{"key":24,"text":268,"correct":22},".电压降低",{"key":28,"text":270,"correct":26},".电流减小",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":42,"analysis":30},717039,"变压器电流速断保护的灵敏度校验,规程规定要求()。",[275,277,279,281],{"key":20,"text":276,"correct":26},".＞4",{"key":24,"text":278,"correct":26},".＜4",{"key":28,"text":280,"correct":26},".＜2",{"key":42,"text":282,"correct":22},".＞2",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":28,"analysis":30},717040,"电动机的各种非接地的不对称故障包括电动机匝间短路、断相、()以及供电电压较大不平衡等。",[287,289,290],{"key":20,"text":288,"correct":26},".三相短路",{"key":24,"text":81,"correct":26},{"key":28,"text":291,"correct":22},".相序接反",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":20,"analysis":30},717041,"当低电压继电器动作时,动断触点()。",[296,298,300],{"key":20,"text":297,"correct":22},".闭合",{"key":24,"text":299,"correct":26},".断开",{"key":28,"text":301,"correct":26},".任意位置",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":24,"analysis":30},717042,"为保证内部短路故障时差动保护的灵敏度,变压器差动保护动作作特性采用()。",[306,308,310,312],{"key":20,"text":307,"correct":26},".低电压闭锁",{"key":24,"text":309,"correct":22},".比率制动特性",{"key":28,"text":311,"correct":26},".低电流闭锁",{"key":42,"text":313,"correct":26},".动作圆特性",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":24,"analysis":30},717043,"用于反应本线路瞬时电流速断保护范围以外的故障,同时作为瞬时电流速断保护的后备的保护为()。",[318,320,322],{"key":20,"text":319,"correct":26},".零序电流I段保护",{"key":24,"text":321,"correct":22},".限时电流速断保护",{"key":28,"text":323,"correct":26},".距离保护I段保护",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":24,"analysis":30},717044,"电力系统发生相间短路时的主要特征是()。",[328,329,331],{"key":20,"text":270,"correct":26},{"key":24,"text":330,"correct":22},".电流增大",{"key":28,"text":332,"correct":26},".电压升高",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":28,"analysis":30},717045,"继电保护动作时仅将故障部分切除,使非故障部分继续运行,停电范围尽可能小,这是指保护具有较好的()。",[337,339,341],{"key":20,"text":338,"correct":26},".灵敏性",{"key":24,"text":340,"correct":26},".快速性",{"key":28,"text":342,"correct":22},".选择性",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":28,"analysis":30},717046,"变压器电流速断保护动作电流按躲过变压器()母线短路时流过保护的最大短路电流,并躲过变压器空载投入时的励磁涌流整定。",[347,349,351],{"key":20,"text":348,"correct":26},".电源侧",{"key":24,"text":350,"correct":26},".电源侧及负荷侧",{"key":28,"text":352,"correct":22},".负荷侧",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":20,"analysis":30},717047,"电火花和电弧是引起电气火灾的重要原因,因为电火花的温度较高,可达(),易燃物容易被点燃。",[357,359,361],{"key":20,"text":358,"correct":22},"3000℃-6000℃",{"key":24,"text":360,"correct":26},"1000℃-2000℃",{"key":28,"text":362,"correct":26},"500℃-800℃",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":28,"analysis":30},717048,"绝缘监视装置反应中性点不接地系统发生单相接地故障时,由()动作后接通信号回路,给出接地故障信号。",[367,369,371],{"key":20,"text":368,"correct":26},".过电流继电器",{"key":24,"text":370,"correct":26},".低电压继电器",{"key":28,"text":372,"correct":22},".过电压继电器",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":20,"analysis":30},717049,"继电保护反映电力系统元件和电气设备的(),将自动地、有选择性地、迅速地将故障元件或设备切除,保证非故障部分继续运行,将故障影响限制在最小范围。",[377,379,381],{"key":20,"text":378,"correct":22},".故障",{"key":24,"text":380,"correct":26},".完好状态",{"key":28,"text":382,"correct":26},".正常运行状态",{"id":384,"libraryId":5,"type":15,"typeLabel":16,"stem":385,"options":386,"answer":28,"analysis":30},717050,"从故障切除时间考虑,原则上继电保护动作时间应()。",[387,389,391],{"key":20,"text":388,"correct":26},".越短越好",{"key":24,"text":390,"correct":26},".越长越好",{"key":28,"text":392,"correct":22},".无要求,动作就行",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":24,"analysis":30},717051,"我国电力系统中性点接地方式分为()与非直接接地两大类。",[397,399,401],{"key":20,"text":398,"correct":26},".中性点经电抗接地",{"key":24,"text":400,"correct":22},".中性点直接接地",{"key":28,"text":402,"correct":26},".中性点经电阻接地",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":24,"analysis":30},717052,"规程规定:35kV电网中接地电流大于10A时,中性点接地方式采用()。",[407,409,411],{"key":20,"text":408,"correct":26},".直接接地",{"key":24,"text":410,"correct":22},".经消弧线圈接地",{"key":28,"text":412,"correct":26},".经电阻接地",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":20,"analysis":30},717053,"备用电源自动投入装置动作时间应以()为原则,以减少电动机的自起动时间。",[417,419,421,423],{"key":20,"text":418,"correct":22},".负荷停电时间尽可能短",{"key":24,"text":420,"correct":26},".负荷停电时间尽可能长",{"key":28,"text":422,"correct":26},".自投成功率尽可能低",{"key":42,"text":424,"correct":26},".设备故障率尽可能低",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":28,"analysis":30},717054,"电力系统中联系发电厂与用户的中间环节称为()。",[429,431,433],{"key":20,"text":430,"correct":26},".送电线路",{"key":24,"text":432,"correct":26},".配电线路",{"key":28,"text":434,"correct":22},".电力网",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":20,"analysis":30},717055,"高压电动机运行中可能发生的主要故障有()、单相接地短路以及一相绕组的匝间短路。",[439,441,443],{"key":20,"text":440,"correct":22},".电动机定子绕组的相间短路故障",{"key":24,"text":442,"correct":26},".低压套管短路故障",{"key":28,"text":444,"correct":26},".高压套管短路故障",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":20,"analysis":30},717056,"对中性点不接地系统,发生单相故障时故障线路零序电流等于各非故障线路对地电容电流之和,由此可以实现()。",[449,451,453],{"key":20,"text":450,"correct":22},".基于零序电流大小选出故障线路",{"key":24,"text":452,"correct":26},".基于零序功率选出故障线路",{"key":28,"text":454,"correct":26},".基于零序电压大小选出故障线路",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":20,"analysis":30},717057,"变电站自动化系统按系统结构可分为集中式、分布式和()三种类型。",[459,461,462,463],{"key":20,"text":460,"correct":22},".分散式",{"key":24,"text":38,"correct":26},{"key":28,"text":40,"correct":26},{"key":42,"text":43,"correct":26},{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":20,"analysis":30},717058,"正常运行时变压器差动保护中,流入差动继电器的电流为()。",[468,470,472,474],{"key":20,"text":469,"correct":22},".不平衡电流",{"key":24,"text":471,"correct":26},".低压侧电流",{"key":28,"text":473,"correct":26},".高压侧电流",{"key":42,"text":475,"correct":26},".负荷电流",{"id":477,"libraryId":5,"type":15,"typeLabel":16,"stem":478,"options":479,"answer":20,"analysis":30},717059,"对上、下级保护之间进行灵敏度配合时,下级保护灵敏度应比上级保护灵敏度()。",[480,482,484],{"key":20,"text":481,"correct":22},".高",{"key":24,"text":483,"correct":26},".低",{"key":28,"text":485,"correct":26},".相等",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":28,"analysis":30},717060,"零序电流II段的保护范围为()。",[490,492,494],{"key":20,"text":491,"correct":26},".本线路全长",{"key":24,"text":493,"correct":26},".本线路及下级线路全长",{"key":28,"text":495,"correct":22},".本线路全长及下级线路一部分",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":28,"analysis":30},717061,"在本线路定时限过电流保护和相邻线路瞬时电流速断保护的保护范围重叠区发生短路时()。",[500,502,504],{"key":20,"text":501,"correct":26},".只有瞬时电流速断保护拒动才起动",{"key":24,"text":503,"correct":26},".只有限时电流速断保护拒动才起动",{"key":28,"text":505,"correct":22},".均会起动",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":20,"analysis":30},717062,"某电力公司管辖的单侧有电源的辐射形电网,如同一地点发生最大运行方式下三相短路或最小运行方式两相短路,则()。",[510,512,514],{"key":20,"text":511,"correct":22},".最大运行方式下三相短路电流大于最小运行方式两相短路",{"key":24,"text":513,"correct":26},".最大运行方式下三相短路电流等于最小运行方式两相短路",{"key":28,"text":515,"correct":26},".最大运行方式下三相短路电流小于最小运行方式两相短路",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":24,"analysis":30},717063,"电动机的各种非接地的不对称故障包括电动机匝间短路、()、相序接反以及供电电压较大不平衡等。",[520,521,523],{"key":20,"text":81,"correct":26},{"key":24,"text":522,"correct":22},".断相",{"key":28,"text":524,"correct":26},".过电流",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":28,"analysis":30},717064,"变电站自动化系统按系统结构可分为()、分布式和分散式三种类型。",[529,530,531,533],{"key":20,"text":40,"correct":26},{"key":24,"text":38,"correct":26},{"key":28,"text":532,"correct":22},".集中式",{"key":42,"text":43,"correct":26},{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":42,"analysis":30},717065,"电力系统短路中()为对称短路。",[538,540,542,544],{"key":20,"text":539,"correct":26},".两相接地短路",{"key":24,"text":541,"correct":26},".两相短路",{"key":28,"text":543,"correct":26},".单相接地短路",{"key":42,"text":288,"correct":22},[546,549,552,554,557,560],{"id":547,"name":548,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":550,"name":551,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":553,"name":551,"category":7,"favorite":8},336,{"id":555,"name":556,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":558,"name":559,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":561,"name":562,"category":7,"favorite":8},353,"(N1)叉车司机"]