[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-392-13":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":557},{"id":5,"name":6,"category":7,"favorite":8},392,"继电保护","特种作业",0,13,50,1668,[13,31,44,56,64,74,86,96,106,116,128,138,148,160,170,182,194,204,215,225,237,249,259,271,281,290,300,312,324,334,346,356,368,378,385,397,407,417,427,439,449,459,469,479,491,503,513,525,535,545],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":30},716966,1,"单选题","电动机容量在5MW以下时,纵差动保护采用()接线。",[19,23,27],{"key":20,"text":21,"correct":22},"A",".一相式",false,{"key":24,"text":25,"correct":26},"B",".两相式",true,{"key":28,"text":29,"correct":22},"C",".三相式","",{"id":32,"libraryId":5,"type":15,"typeLabel":16,"stem":33,"options":34,"answer":28,"analysis":30},716967,"当工作电源因故障自动跳闸后,自动迅速地将备用电源投入的一种自动装置称为()。",[35,37,39,41],{"key":20,"text":36,"correct":22},".低频减载装置",{"key":24,"text":38,"correct":22},".自动重合闸装置",{"key":28,"text":40,"correct":26},".备用电源自动投入装置",{"key":42,"text":43,"correct":22},"D",".低压减载装置",{"id":45,"libraryId":5,"type":15,"typeLabel":16,"stem":46,"options":47,"answer":24,"analysis":30},716968,"根据现场设备的分散地点分别安装现场单元,现场单元可以是微机保护和监控功能二合一的装置,也可以是微机保护和监控部分各自独立的方式称为()变电站自动化系统。",[48,50,52,54],{"key":20,"text":49,"correct":22},".集中式",{"key":24,"text":51,"correct":26},".分散分布式",{"key":28,"text":53,"correct":22},".微机式",{"key":42,"text":55,"correct":22},".主从式",{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":20,"analysis":30},716969,"电力系统自动装置可分为()和自动操作装置两大类。",[60,62,63],{"key":20,"text":61,"correct":26},".自动调节装置",{"key":24,"text":40,"correct":22},{"key":28,"text":38,"correct":22},{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":28,"analysis":30},716970,"针对电力系统可能发生的故障和异常运行状态,需要()。",[68,70,72],{"key":20,"text":69,"correct":22},".加强安全教育",{"key":24,"text":71,"correct":22},".购买新设备",{"key":28,"text":73,"correct":26},".装设继电保护装置",{"id":75,"libraryId":5,"type":15,"typeLabel":16,"stem":76,"options":77,"answer":28,"analysis":30},716971,"采用二次谐波制动原理构成的变压器差动保护由()、二次谐波制动、差动速断元件及TA断线检测等部分构成。",[78,80,82,84],{"key":20,"text":79,"correct":22},".延时元件",{"key":24,"text":81,"correct":22},".电压元件",{"key":28,"text":83,"correct":26},".差动元件",{"key":42,"text":85,"correct":22},".功率方向元件",{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":20,"analysis":30},716972,"对中性点不接地系统,发生单相故障时故障线路零序电流方向为由线路流向母线,非故障线路零序电流方向为由母线流向线路,由此可以实现()。",[90,92,94],{"key":20,"text":91,"correct":26},".基于零序功率选出故障线路",{"key":24,"text":93,"correct":22},".基于零序电流大小选出故障线路",{"key":28,"text":95,"correct":22},".基于零序电压大小选出故障线路",{"id":97,"libraryId":5,"type":15,"typeLabel":16,"stem":98,"options":99,"answer":20,"analysis":30},716973,"备用电源自动投入装置工作时,当备用电源无压时,备用电源自动投入装置()。",[100,102,104],{"key":20,"text":101,"correct":26},".不应动作",{"key":24,"text":103,"correct":22},".应迅速动作",{"key":28,"text":105,"correct":22},".应延时动作",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":30},716974,"零序电流通过系统的()和接地故障点形成短路回路。",[110,112,114],{"key":20,"text":111,"correct":22},"A相",{"key":24,"text":113,"correct":26},"接地中性点",{"key":28,"text":115,"correct":22},"B相",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":28,"analysis":30},716975,"线路纵差保护可以反应()的故障。",[120,122,124,126],{"key":20,"text":121,"correct":22},".本条线路全部和下条线路一部分",{"key":24,"text":123,"correct":22},".本条线路一部分",{"key":28,"text":125,"correct":26},".两侧电流互感器之间任何地点",{"key":42,"text":127,"correct":22},".下条线路",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":24,"analysis":30},716976,"下列设备中()没有灭弧机构,不允许切断和接通负荷电流。",[132,134,136],{"key":20,"text":133,"correct":22},".控制开关",{"key":24,"text":135,"correct":26},".隔离开关",{"key":28,"text":137,"correct":22},".真空断路器",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":30},716977,"备用电源自动投入装置动作时,通过合备用线路断路器或()断路器实现备用电源的投入。",[142,144,146],{"key":20,"text":143,"correct":22},".工作线路",{"key":24,"text":145,"correct":26},".备用变压器",{"key":28,"text":147,"correct":22},".工作母线",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":42,"analysis":30},716978,"变压器纵差动保护或电流速断保护可以反应引出线的短路故障以及()。",[152,154,156,158],{"key":20,"text":153,"correct":22},".过电压",{"key":24,"text":155,"correct":22},".过负荷",{"key":28,"text":157,"correct":22},".油箱漏油造成油面降低",{"key":42,"text":159,"correct":26},".变压器绕组、套管故障",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":24,"analysis":30},716979,"当伤者牙关紧闭,无法进行口对口人工呼吸时,应()。",[164,166,168],{"key":20,"text":165,"correct":22},"用工具把嘴撬开",{"key":24,"text":167,"correct":26},"口对鼻吹气",{"key":28,"text":169,"correct":22},"加大压力口对口吹气",{"id":171,"libraryId":5,"type":15,"typeLabel":16,"stem":172,"options":173,"answer":28,"analysis":30},716980,"微机保护硬件结构由数据采集系统、开关量输入\u002F输出系统、()组成。",[174,176,178,180],{"key":20,"text":175,"correct":22},".软件算法",{"key":24,"text":177,"correct":22},".中断程序",{"key":28,"text":179,"correct":26},".微机主系统",{"key":42,"text":181,"correct":22},".逻辑判断",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":20,"analysis":30},716981,"微机型变压器差动保护其幅值调整与相位补偿一般通过()实现。",[186,188,190,192],{"key":20,"text":187,"correct":26},".软件计算算法",{"key":24,"text":189,"correct":22},".改变电流互感器变比",{"key":28,"text":191,"correct":22},".改变变压器接线",{"key":42,"text":193,"correct":22},".改变电流互感器接线",{"id":195,"libraryId":5,"type":15,"typeLabel":16,"stem":196,"options":197,"answer":24,"analysis":30},716982,"在电力系统事故情况下,可能出现较大的()缺额,造成电力系统频率较大幅度下降。",[198,200,202],{"key":20,"text":199,"correct":22},".无功功率",{"key":24,"text":201,"correct":26},".有功功率",{"key":28,"text":203,"correct":22},".视在功率",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":20,"analysis":30},716983,"变压器过电流保护可以反应()。",[208,210,212,213],{"key":20,"text":209,"correct":26},".外部故障引起的过电流",{"key":24,"text":211,"correct":22},".三相对称过负荷",{"key":28,"text":157,"correct":22},{"key":42,"text":214,"correct":22},".变压器高压侧系统的接地故障",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":20,"analysis":30},716984,"进线备自投接线的动作过程描述为()。",[219,221,223],{"key":20,"text":220,"correct":26},".工作线路失压跳闸,监测工作线路无流、备用线路有电压时,投入备用线路",{"key":24,"text":222,"correct":22},".工作线路失压跳闸,监测工作线路无流、备用线路有电压时,投入工作线路",{"key":28,"text":224,"correct":22},".工作线路失压跳闸,监测备用线路无流、工作线路有电压时,投入工作线路",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":42,"analysis":30},716985,"变压器励磁涌流中含有明显的()分量,其中二次谐波分量比例最大。",[229,231,233,235],{"key":20,"text":230,"correct":22},".周期",{"key":24,"text":232,"correct":22},".高次谐波",{"key":28,"text":234,"correct":22},".间断角",{"key":42,"text":236,"correct":26},".非周期",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":24,"analysis":30},716986,"变压器电流速断保护动作电流按躲过(),并躲过变压器空载投入时的励磁涌流整定。",[241,243,245,247],{"key":20,"text":242,"correct":22},".变压器负荷侧母线短路时流过保护的最小短路电流",{"key":24,"text":244,"correct":26},".变压器负荷侧母线短路时流过保护的最大短路电流",{"key":28,"text":246,"correct":22},".最大负荷电流",{"key":42,"text":248,"correct":22},".最小负荷电流",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":24,"analysis":30},716987,"短路全电流中的最大瞬时值称为()。",[253,255,257],{"key":20,"text":254,"correct":22},".非周期分量电流",{"key":24,"text":256,"correct":26},".短路冲击电流",{"key":28,"text":258,"correct":22},".周期分量电流",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":42,"analysis":30},716988,"某电动机电流速断保护采用高、低两个整定值,在电动机起动时()。",[263,265,267,269],{"key":20,"text":264,"correct":22},".由高、低定值同时躲过起动电流,保护不动",{"key":24,"text":266,"correct":22},".由低定值躲过起动电流,保护不动作",{"key":28,"text":268,"correct":22},".由低定值起动保护,动作出口切除电动机",{"key":42,"text":270,"correct":26},".由高定值躲过起动电流,保护不动作",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":24,"analysis":30},716989,"定时限过电流保护近后备灵敏系数计算为()。",[275,277,279],{"key":20,"text":276,"correct":22},".最大运行方式本线路末端三相短路电流与动作电流之比",{"key":24,"text":278,"correct":26},".最小运行方式本线路末端两相短路电流与动作电流之比",{"key":28,"text":280,"correct":22},".最小运行方式下级线路末端两相短路电流与动作电流之比",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":20,"analysis":30},716990,"变压器低电压起动的过电流保护的电流元件动作电流整定,按照躲过()。",[285,286,288],{"key":20,"text":246,"correct":26},{"key":24,"text":287,"correct":22},".变压器额定电流",{"key":28,"text":289,"correct":22},".最大短路电流",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":24,"analysis":30},716991,"无限大容量系统的特征为()。",[294,296,298],{"key":20,"text":295,"correct":22},".当被供电系统中负荷变动甚至发生故障,电力系统母线电压应维持不变,频率不作要求",{"key":24,"text":297,"correct":26},".当被供电系统中负荷变动甚至发生故障,电力系统母线电压及频率基本维持不变",{"key":28,"text":299,"correct":22},".当被供电系统中负荷变动甚至发生故障,电力系统母线频率应维持不变,电压不作要求",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":24,"analysis":30},716992,"造成变压器差动保护不平衡电流的因素有电流互感器变比标准化、()及变压器分接头调整等。",[304,306,308,310],{"key":20,"text":305,"correct":22},".保护定值偏高",{"key":24,"text":307,"correct":26},".两侧电流互感器二次阻抗不完全匹配",{"key":28,"text":309,"correct":22},".电压互感器的影响",{"key":42,"text":311,"correct":22},".差动继电器动作电流偏小",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":42,"analysis":30},716993,"在变压器差动保护中,由于两侧电流互感器二次阻抗不完全匹配造成的不平衡电流在计算时引入电流互感器同型系数、电流互感器变比误差系数及()等措施。",[316,318,320,322],{"key":20,"text":317,"correct":22},".电流平衡调整",{"key":24,"text":319,"correct":22},".电压互感器的变比调整",{"key":28,"text":321,"correct":22},".电压平衡调整",{"key":42,"text":323,"correct":26},".非周期分量系数",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":20,"analysis":30},716994,"运行经验表明,架空线路故障的性质大多为()。",[328,330,332],{"key":20,"text":329,"correct":26},".瞬时性故障",{"key":24,"text":331,"correct":22},".永久性故障",{"key":28,"text":333,"correct":22},".转换性故障",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":28,"analysis":30},716995,"距离保护装置测量阻抗大于整定阻抗时,说明()。",[338,340,342,344],{"key":20,"text":339,"correct":22},".短路点在保护区内,保护不动作",{"key":24,"text":341,"correct":22},".短路点在保护区外,保护动作",{"key":28,"text":343,"correct":26},".短路点在保护区外,保护不动作",{"key":42,"text":345,"correct":22},".短路点在保护区内,保护动作",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":28,"analysis":30},716996,"在运行中,电流的热量和电火花或()等都是电气火灾的直接原因。",[350,352,354],{"key":20,"text":351,"correct":22},"、环境温度",{"key":24,"text":353,"correct":22},"、电压高低",{"key":28,"text":355,"correct":26},"、电弧",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":28,"analysis":30},716997,"断路器事故跳闸时,发出蜂鸣器音响信号,称为()。",[360,362,364,366],{"key":20,"text":361,"correct":22},".位置信号",{"key":24,"text":363,"correct":22},".预告信号",{"key":28,"text":365,"correct":26},".事故信号",{"key":42,"text":367,"correct":22},".联系信号",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":28,"analysis":30},716998,"电动机过热保护由()、过热跳闸、过热禁止再起动构成。",[372,374,376],{"key":20,"text":373,"correct":22},".过热闭锁",{"key":24,"text":375,"correct":22},".过热起动",{"key":28,"text":377,"correct":26},".过热告警",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":24,"analysis":30},716999,"频率是电力系统运行的一个重要指标,反应电力系统()供需平衡的状态。",[382,383,384],{"key":20,"text":199,"correct":22},{"key":24,"text":201,"correct":26},{"key":28,"text":203,"correct":22},{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":28,"analysis":30},717000,"电力系统中变压器通常采用Y,d11接线方式,为使变压器差动保护回路正常时电流为0,电流互感器采用()和幅值调整。",[389,391,393,395],{"key":20,"text":390,"correct":22},".谐波制动接线",{"key":24,"text":392,"correct":22},".保护接线",{"key":28,"text":394,"correct":26},".相位补偿接线",{"key":42,"text":396,"correct":22},".涌流制动接线",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":20,"analysis":30},717001,"变压器差动保护的差动元件通常采用比率制动特性,内部故障时,制动量()。",[401,403,405],{"key":20,"text":402,"correct":26},".较小",{"key":24,"text":404,"correct":22},".较大",{"key":28,"text":406,"correct":22},".不变",{"id":408,"libraryId":5,"type":15,"typeLabel":16,"stem":409,"options":410,"answer":20,"analysis":30},717002,"在本线路的限时电流速断保护与下级线路瞬时电流速断保护范围的重叠区发生故障,如瞬时电流速断保护拒动,则()。",[411,413,415],{"key":20,"text":412,"correct":26},".本线路的限时电流速断保护动作跳闸",{"key":24,"text":414,"correct":22},".由下级线路瞬时电流速断保护一直动作直到跳闸",{"key":28,"text":416,"correct":22},".保护均不动作",{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":24,"analysis":30},717003,"自动低频减载装置按照频率下降的不同程度,自动分级断开相应的()。",[421,423,425],{"key":20,"text":422,"correct":22},".一级用户",{"key":24,"text":424,"correct":26},".非重要负荷",{"key":28,"text":426,"correct":22},".重要用户",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":20,"analysis":30},717004,"我国变电站一次主接线备用电源自动投入的主要一次接线方案有:低压母线分段备自投接线、变压器备自投接线及()等。",[431,433,435,437],{"key":20,"text":432,"correct":26},".进线备自投接线",{"key":24,"text":434,"correct":22},".暗备用自投",{"key":28,"text":436,"correct":22},".明备用自投",{"key":42,"text":438,"correct":22},".无功备用自投",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":24,"analysis":30},717005,"电流互感器同极性端采用L1、L2、K1、K2标识时,以下表述正确的是()。",[443,445,447],{"key":20,"text":444,"correct":22},".L1、L2为同极性端",{"key":24,"text":446,"correct":26},".L1、K1为同极性端",{"key":28,"text":448,"correct":22},".K1、K2为同极性端",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":20,"analysis":30},717006,"限时电流速断保护灵敏度系数要求()。",[453,455,457],{"key":20,"text":454,"correct":26},".大于1.3-1.5",{"key":24,"text":456,"correct":22},".大于0.5-1.0",{"key":28,"text":458,"correct":22},".小于0.5-1.0",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":28,"analysis":30},717007,"从输电网或地区发电厂接受电能,通过配电设施将电能分配给用户的电力网称为()。",[463,465,467],{"key":20,"text":464,"correct":22},".电力网",{"key":24,"text":466,"correct":22},".输电网",{"key":28,"text":468,"correct":26},".配电网",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":28,"analysis":30},717008,"下列保护中()用于反应任何原因引起电动机定子正序电流增大或出现负序电流导致电动机过热。",[473,475,477],{"key":20,"text":474,"correct":22},".低电压保护",{"key":24,"text":476,"correct":22},".负序电流保护",{"key":28,"text":478,"correct":26},".过热保护",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":28,"analysis":30},717009,"对于具有较高接地电流水平的电动机采用零序电流保护,一般三相均装有电流互感器,由()取得零序电流。",[483,485,487,489],{"key":20,"text":484,"correct":22},".三相电流之积",{"key":24,"text":486,"correct":22},".三相电流之差",{"key":28,"text":488,"correct":26},".三相电流之和",{"key":42,"text":490,"correct":22},".三相电流之比",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":24,"analysis":30},717010,"变压器相间短路的后备保护动作时限与()配合,按阶梯原则整定。",[495,497,499,501],{"key":20,"text":496,"correct":22},".电流速断保护",{"key":24,"text":498,"correct":26},".相邻元件后备保护",{"key":28,"text":500,"correct":22},".变压器差动保护",{"key":42,"text":502,"correct":22},".零序电流保护",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":24,"analysis":30},717011,"电流继电器的文字符号表示为()。",[507,509,511],{"key":20,"text":508,"correct":22},".KV",{"key":24,"text":510,"correct":26},".KA",{"key":28,"text":512,"correct":22},".KM",{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":20,"analysis":30},717012,"将交流一次侧高电压转换成可供控制、测量、保护等二次设备使用的二次侧电压的变压设备称为()。",[517,519,521,523],{"key":20,"text":518,"correct":26},".电压互感器",{"key":24,"text":520,"correct":22},".电流互感器",{"key":28,"text":522,"correct":22},".电流表",{"key":42,"text":524,"correct":22},".电压表",{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":28,"analysis":30},717013,"电动机低定值电流速断保护在()投入。",[529,531,533],{"key":20,"text":530,"correct":22},".电动机起动时",{"key":24,"text":532,"correct":22},".故障时",{"key":28,"text":534,"correct":26},".电动机起动后",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":20,"analysis":30},717014,"电动机在起动过程中或运行中发生堵转,转差率为()。",[539,541,543],{"key":20,"text":540,"correct":26},".1",{"key":24,"text":542,"correct":22},".0.5",{"key":28,"text":544,"correct":22},".2",{"id":546,"libraryId":5,"type":15,"typeLabel":16,"stem":547,"options":548,"answer":28,"analysis":30},717015,"距离保护的测量元件为()。",[549,551,553,555],{"key":20,"text":550,"correct":22},".电流测量元件",{"key":24,"text":552,"correct":22},".电压测量元件",{"key":28,"text":554,"correct":26},".阻抗测量元件",{"key":42,"text":556,"correct":22},".零序电流测量元件",[558,561,564,566,569,572],{"id":559,"name":560,"category":7,"favorite":15},401,"高处安装、维护、拆除",{"id":562,"name":563,"category":7,"favorite":8},335,"(A)特种设备安全管理",{"id":565,"name":563,"category":7,"favorite":8},336,{"id":567,"name":568,"category":7,"favorite":8},340,"D1压力管道巡检维护",{"id":570,"name":571,"category":7,"favorite":8},343,"(G1)工业锅炉司炉",{"id":573,"name":574,"category":7,"favorite":8},353,"(N1)叉车司机"]